Chauvin Arnoux C112 [P01120314] 0.1 - 1200 A AC Clamp Meter Adapter

Not yet rated Write a review
Chauvin Arnoux
Rp.17.663.424
Availability:
2 - 4 WEEKS
Product Code:
P01120314
Brand:
Chauvin Arnoux
Update Terakhir:
22 Nov 2024
  • Free delivery

  • Money back guarantee

Share

Chauvin Arnoux C112 [P01120314] 0.1 - 1200 A AC Clamp Meter Adapter. The Chauvin Arnoux C112 AC 00011200A (1A AC)[F] Current Clamp is an ergonomically designed, safe to use and accurate electrical testing current clamp from the C Series range offered by Chauvin Arnoux. The device range was designed especially for its usability, accuracy and above all safety measures. You can attach the device to any number of instruments, including multimeters, oscillators, recorders and wattmeters. Also, when you are electrical testing with this current clamp, you won’t have to worry about any circuit breakage when you are retrieving AC measurements.  When it comes to safety, Chauvin Arnoux have looked to ensure they create their safest current clamp yet with anti-slipping and anti-pinching protection technology win place. This means that the Chauvin Arnoux C112 AC 00011200A (1A AC)[F] Current Clamp has been constructed to avoid slipping out of place as well as preventing any pinching damage being left on the conductor when you are electrical testing.  The device is also extremely usable and ergonomic. The sleek shape means you can get a perfect hold on the device. Not only that, but you grip will be much more secure thanks to the added finger grips on the handles. You will be able to open the clamp with the utmost ease thanks to the assisted jaw opening technology on the Chauvin Arnoux C112 AC 00011200A (1A AC)[F] Current Clamp. The accuracy of the Chauvin Arnoux C112 AC 00011200A (1A AC)[F] Current Clamp is an excellent benefit. The occurrence of phase shift has been greatly reduced because of the symmetrical coil winding technology that Chauvin Arnoux have installed into this current clamp. That also helps contribute to the less than 0.5% output signal accuracy. The device can operate at a primary current of 1200A and can retrieve measurements up to 1000A. 

  • Part Number: P01120314
  • Current : 1,000 A
  • Ratio : 1000 / 1
  • Output : 1 mA / A
  • Output signal: AC voltage
  • Output/input ratio: 1 mV / A AC
  • Output via isolated Ø 4 mm female sockets
  • Output protected against voltage surges

  • ELECTRICAL SPECIFICATIONS:
  • Current range: 0.001 A AC .. 1,200 A AC
  • Current transformation ratio: 1000:1
  • Output signal: 1 mA AC / A AC (1 A for 1,000 A)
  • Accuracy and phase shift (1):
  • Primary current: 0.1 A .. 100 mA, 0.1 A .. 1 A, 1 A .. 10 A,  10 A .. 100 A,  100 A .. 1,200 A
  • % Accuracy of output signal: ≤ 3 % + 5 µA, ≤ 2 % + 3 µA, ≤ 1 %, ≤ 0.5 % , ≤ 0.3 %
  • Phase shift: not specified, not specified, ≤ 2°, ≤ 1°, ≤ 0.7°
  • Bandwidth: 30 Hz .. 10 kHz
  • Crest factor: ≤ 6 for a current ≤ 2,000 A peak (300 ARMS)
  • Maximum currents: 1,000 A continuous for a frequency ≤ 1 kHz (limitation proportional to the inverse of frequency beyond) 1,200 A for 40 minutes max (interval between measurements > 20 minutes)
  • Load impedance: ≤ 1 Ω
  • Max. voltage output: Electronic protection circuit limiting voltage to 30 V peak max
  • Operating voltage: 600 VRMS
  • Common mode voltage: 600 V category III and pollution degree 2
  • Influence of adjacent conductor: ≤ 0.5 mA / A at 50 Hz
  • Influence of conductor position in jaws: ≤ 0.1 % of output signal for frequencies ≤ 400 Hz
  • Load influence: From 1 Ω to 5 Ω; < 0.1 % on measurement; < 0.2° on phase
  • Influence of frequency (2): < 0.5 % of output signal from 30 Hz .. 48 Hz; < 1 % of output signal from 65 Hz .. 1 kHz; < 2 % of output signal from 1 kHz .. 5 kHz
  • Influence of crest factor: < 1 % of output signal for crest factor ≤ 6 with current ≤ 2,000 A peak (300 A RMS)
  • Influence of DC current superimposed on rated current: < 1 % of output signal for a current ≤ 15 A DC
  • MECHANICAL SPECIFICATIONS:
  • Operating temperature: -10 °C to +50 °C
  • Storage temperature: -40 °C to +70 °C
  • Influence of temperature: ≤ 0.2 % of output signal per 10 °K
  • Relative humidity for operation: 0 to 85 % RH with a linear decrease above 35 °C
  • Influence of relative humidity: < 0.1 % of output signal from 10 % to 85 % RH
  • Operating altitude: 0 to 2,000 m
  • Max. jaw opening: 53 mm, patented progressive opening system
  • Clamping capacity: Cable: Ø max 52 mm; Busbar: 1 busbar of 50 x 5 mm / 4 busbars of 30 x 5 mm
  • Casing protection rating: IP40 (IEC 529)
  • Drop test: 1 m (IEC 68-2-32)
  • Shock resistance: 100 g (IEC 68-2-27)
  • Vibration resistance: 5/15 Hz 1.5 mm, 15/25 Hz 1 mm, 25/55 Hz 0.25 mm (IEC 68-2-6)
  • Self-extinguishing capability: Casing and jaws: UL94 V0
  • Dimensions: 216 x 111 x 45 mm
  • Weight: 550 g
  • Colours: Dark grey case with red jaws
  • Output: C112: Safety sockets (4 mm); C113: two-wire cable with reinforced insulation or double insulation, length 1.5 m, terminated by 2 insulated elbowed male banana plugs (4 mm)
  • SAFETY SPECIFICATIONS:
  • Electrical safety: Instrument with double insulation or reinforced insulation between the primary the secondary and the grippable part located under the guard as per IEC 1010-1 & IEC 1010-2-032
  • 600 V category III, pollution degree 2
  • 300 V category IV, pollution degree 2
  • Electromagnetic compatibility (EMC): EN 50081-1: class B; EN 50082-2:
  • Electrostatic discharge: IEC 1000-4-2
  • Radiated field: IEC 1000-4-3
  • Fast transients: IEC 1000-4-4
  • Magnetic field at 50/60 Hz: IEC 1000-4-8
  • (1) Conditions of reference: 23 °C ± 3 °K, 20 % to 75 % RH, signal sinus, frequency of 48 Hz to 65 Hz, distortion factor < 1 %, no DC components, external magnetic fi eld < 40 A/m, no AC magnetic fi eld, conductor centred for measurement, load impedance 1 Ω (1 VA)
  • (2) Out of reference domain.

  • (1) C112 - Clamp Meter Adapter
  • (1) Instruction Manual

Download

Note: Prices are not binding at any time subject to change without prior notice


  Options 0 Item Selected
Image
Model
Product Name
Price
Available
Quantity
Chauvin Arnoux C112 [P01120314] 0.1 - 1200 A AC Clamp Meter Adapter
P01120314
Rp.17.663.424
2 - 4 WEEKS
Chauvin Arnoux C113 [P01120315] 0.1 - 1200 A AC Clamp Meter Adapter
P01120315
Rp.18.030.838
2 - 4 WEEKS
Chauvin Arnoux C116 [P01120316] 0.001 - 1200 A AC Current Clamp Adapter
P01120316
Rp.18.030.838
2 - 4 WEEKS
Chauvin Arnoux C117 [P01120317] 0.001 - 1200 A AC Current Clamp Adapter
P01120317
Rp.18.341.828
2 - 4 WEEKS
Chauvin Arnoux C122 [P01120306] 1 - 1200 A AC Current Clamp Adapter
P01120306
Rp.16.305.962
2 - 4 WEEKS
Chauvin Arnoux C148 [P01120307] 1- 300/600/1200A A AC Current Clamp Adapter
P01120307
Rp.20.830.400
2 - 4 WEEKS
Chauvin Arnoux C100 [P01120301] 0.1 - 1200 A AC Clamp Meter Adapter
P01120301
Rp.13.332.863
2 - 4 WEEKS
Chauvin Arnoux C102 [P01120302] 0.1 - 1200 A AC Clamp Meter Adapter
P01120302
Rp.14.213.344
2 - 4 WEEKS
Chauvin Arnoux C103 [P01120303] 0.1 - 1200 A AC Clamp Meter Adapter
P01120303
Rp.14.552.873
2 - 4 WEEKS
Chauvin Arnoux C106 [P01120304] 0.1 - 1200 A AC Clamp Meter Adapter
P01120304
Rp.16.136.361
2 - 4 WEEKS
Chauvin Arnoux C107 [P01120305] 0.1 - 1200 A AC Clamp Meter Adapter
P01120305
Rp.16.475.563
2 - 4 WEEKS