• Amprobe AM-510 [4018636] Commercial/Residential Multimeter

Amprobe AM-510 [4018636] Commercial/Residential Multimeter

Not yet rated Write a review
Amprobe
Rp.2.500.000
Availability:
2 - 4 WEEKS
Product Code:
4018636
Brand:
Amprobe
Update Terakhir:
13 May 2017
This product has a minimum quantity of 5
  • Free delivery

  • Money back guarantee

Ask an Expert

Our tech experts are ready to help!

(62) 021-53167044 | 0812-83861970 | 0812-9915277

Email Us

Share

The Amprobe AM-510 Commercial/Residential Multimeter is designed for light commercial and advanced residential applications. Re-wire electrical panels, install heated floors or new light fixtures, troubleshoot and repair home appliances, electrical sockets and automotive electrical problems with this easy-to-use multimeter. The AM-510 features a built-in flashlight to see wires and fuses in the dark, a rubber tilt stand and probe holder to give you the "third-hand" you need while taking measurements.

The AM-510 offers safety features including Voltect non-contact voltage detection for quick go/no-go checks without the need for an additional tool. Compact yet tough, this multimeter is built to last through all your electrical projects.

There are no reviews for this product.

Write a review

  • Voltage up to 600V ac/dc, ac/dc current and resistance
  • Frequency, capacitance, duty cycle for troubleshooting applications
  • VolTect™ Non-contact voltage detection
  • Audible continuity
  • Diode test
  • Backlit LCD display
  • Data hold
  • Relative zero mode
  • Built-in flashlight
  • Built-in test leads storage and “third hand probe holder
  • Auto and manual-ranging
  • Auto power off
  • Low battery warning
  • Safety: CAT III 600V

                          • AC Voltage:
                          • Range: 400 mV, 4.000 V, 40.00 V
                          • Accuracy:  +/- (1.0 % rdg + 3 LSD)
                          • Range: 400.0 V, 600 V
                          • Accuracy: @ 45 Hz to 400 Hz, 4 V to 400V ranges
                          • DC Voltage:
                          • Range: 400 mV, 4.000 V, 40.00 V
                          • Accuracy: +/- (0.8% rdg + 1 LSD)
                          • Range: 400.0 V, 600 V
                          • Accuracy: @ 4 V to 400 V ranges
                          • Resistance:
                          • Range: 400.0 µA, 4000 µA; 40.00 mA, 400.0 mA; 4.000 A, 10.00 A
                          • Accuracy:  +/- (1.2% rdg + 3 LSD)
                          • AC Current:
                          • Range:  400.0 µA, 4000 µA; 40.00 mA, 400.0 mA; 4.000 A, 10.00 A
                          • Accuracy: +/- (1.0% rdg + 2 LSD)
                          • DC Current:
                          • Range: 400.0 Ω; 4.000 kΩ, 40.00 kΩ, 400.0 kΩ, 4.000 MΩ, 40.00 MΩ
                          • Accuracy: +/- (1.0% rdg + 2 LSD) @ 4 kΩ to 400 kΩ ranges
                          • Battery test: 0.1% to 99.9%  
                          • Duty cycle:
                          • Range: 1.5V, 9
                          • Accuracy: +/- (1.0% rdg + 3 LSD)
                          • Ambient temperature:
                          • 23°C ±5°C (73.4°F ±9°F)
                          • Relative temperature:  =75%
                          • Accuracy: ±(% of reading + digits)
                          • Maximum voltage between input terminal and earth ground: AC 600Vrms or DC 600V
                          • Fuse for mA µA input: 0.5A H 600V fast-fuse, (Φ6×32)mm
                          • Fuse for 10A input: 10A H 600V fast-fuse, (Φ6×32)mm
                          • Maximum display: Digital 3999 counts, updates 3/sec. Frequency: 4999 counts
                          • Over-range indication: OL
                          • Range: Automatic
                          • Altitude: Operating = 2000m
                          • Operating temperature: 0°C ~ +40°C (32°F ~ 104°F)
                          • Relative humidity 0°C: ~ +30°C (32°F ~ 86°F) =75%; +30°C ~ +40°C (86°F ~ 104°F) =50%
                          • Storage temperature: -10°C ~ +50°C (14°F ~ 122°F)
                          • Electromagnetic compatibility: In an RF filed of 1V/m = Speci?ed accuracy ±5%
                          • Battery: 9V, 6F22, NEDA1604 or equivalent
                          • Dimensions (L x W x H): 182 mm x 90 mm x 45 mm (7.2 in x 3.5 in x 1.8 in)
                          • Weight: Approx. 354g (0.78lb) with batteries installed
                          DC Voltage Measurement
                          • Input impedance: around 10MΩ; (Input impedance > 3GΩ for DC 400mV range)
                          • Overload protection: ?600V
                          AC Voltage Measurement
                          • Note: 400.0mV range is available for manual range only.
                          • Input impedance: around 10MΩ
                          • Frequency response: 45Hz ~ 400Hz
                          Average sensing, rms indication:
                          • Overload protection: 600Vrms
                          Resistance Measurement
                          • 400Ω range: Measured value = (Measured display value) ? (Short-circuiting value of probe)
                          • Open circuit voltage: around 0.5V
                          • Overload protection: 600Vrms
                          Continuity and Diode measurement
                          • Overload protection: 600Vrms
                          Capacitance Measurement
                          • Overload protection: 600Vrms
                          Measurement of frequency/duty cycle
                          • Overload protection: 600Vrm
                          • Input amplitude (DC level is 0.)
                          • 10Hz~1MHz: 300mV ≤ a ≤30Vrms
                          • >1MHz~10MHz: 600mV ≤ a ≤30Vrms
                          • Input amplitude and frequency response must meet following conditions when reading frequency or duty cycle during AC voltage or current measurement
                          • Input amplitude = Range × 30%
                          • Frequency response: =400Hz
                          Battery Test:
                          • Overload protection: F1 fuse, 0.5A H 600V fast-fuse, (Φ6x32)mm
                          • For 1.5V range: Load resistance is around 30Ω.
                          • For 9V range: Load resistance is around 1kΩ
                          DC Current Measurement
                          • Overload protection: mA /μA input:F1 fuse, 0.5A H 600V fast-fuse, (Φ6x32)mm
                          • 10 A input: F2 fuse, 10A H 600V fast-fuse, (Φ6x32)mm
                          AC Current Measurement
                          • Frequency response: 45Hz ~ 400Hz Average sensing, rms indication
                          • Overload protection: mA /μA input:F1 fuse, 0.5A H 600V fast-fuse, (Φ6x32)mm
                          • 10 A input: F2 fuse, 10A H 600V fast-fuse, (Φ 6x32)mm

                          • (1) 9V (6F22) x1 battery installed
                          • (1) Test leads
                          • (1) Users manual