  • Aalborg DPC57 Mass Flow Controller, 1/2” NPT Female, 250 sL/min

Aalborg DPC57 Mass Flow Controller, 1/2” NPT Female, 250 sL/min

Not yet rated Write a review
Aalborg

Available Options

Rp.58.716.500
Availability:
4 - 6 WEEKS
Product Code:
DPC57
Brand:
Aalborg
Update Terakhir:
08 Jul 2021
  • Free delivery

  • Money back guarantee

Ask an Expert

Our tech experts are ready to help!

(62) 021-53167044 | 0812-83861970 | 0812-9915277

Email Us

Share

Aalborg Instruments' DPC series precision digital mass flow controllers provide accurate and stable control of mass flow rate, of process gases. Inherent simultaneous displays of Mass Flow, Volumetric Flow, Pressure and Temperature parameters promote applications in a variety of industries such as scientific and analytical applications, bioreactors and surface depositions, gas sampling, manufacturing and metrology activities.

DPC precision digital mass flow controllers incorporate multi-gas functionalities allowing users on site to select up to 30 different gases locally via optional OLED/Joystick interface, remotely via the RS232/RS485 interface or optional Modbus RTU interface.

DPC flow controllers support various functions including: user selectable local, analog, digital or program set point control, two programmable flow totalizers, LOW, HIGH or RANGE FLOW, temperature and pressure alarms, automatic zero adjustment (activated via local or communication interface), programmable SSR relay, programmable 0-5 Vdc, 0-10 Vdc or 4-20 mA analog inputs and outputs, user-programmable pulse output (via SSR), and extensive self-diagnostics functionality. AALBORG DPC series mass flow controllers Totalizers with batch processing mode, high ±(0.5% RD + 0.2%FS) standard accuracy, 200:1 turn-down ratio and less than 150 ms response time allow users to save considerable costs of owning and installation discreet application specific instruments required to perform similar control and measurement.

There are no reviews for this product.

Write a review

  • Multi-Gas functionality: support for 90 different gases and gas mixes.
  • Create and store up 20 custom gas mixes with up to 5 different gases each.
  • 100-150 ms response time
  • ± (0.5% RD + 0.2% FS) accuracy
  • 200 to 1 turn-down ratio
  • Two programmable mass flow rate totalizers
  • Self diagnostics with status LED or OLED indication
  • RS-232 and RS-485
  • 0-5Vdc, 0-10Vdc, 4-20mA
  • 12-26 Vdc power supply input

FLOW MEDIUM: Please note that DPC Mass Flow Controllers are designed to work only with clean, non-corrosive gases. Never try to control fl ow rates of liquids with any DPC
CALIBRATIONS: Performed at standard conditions [14.7 psia (101.4 kPa) and 70 °F (21.1 °C)] unless otherwise requested or stated.
ENVIRONMENTAL (PER IEC 664): Installation Level II; Pollution Degree II.
FLOW ACCURACY (INCLUDING LINEARITY): ±(0.5% RD + 0.2% FS) at calibration temperature and pressure conditions after tare
REPEATABILITY: ±0.2% of full scale.
FLOW TEMPERATURE COEFFICIENT: 0.05% of full scale/ °C or better.
FLOW PRESSURE COEFFICIENT: 0.01% of full scale/psi (6.895 kPa) or better.
TYPICAL FLOW RESPONSE TIME: Default 150 ms (adjustable).
INSTRUMENT WARM-UP TIME: < 5 seconds.
MAXIMUM CONTROLLABLE FLOW RANGE: 133% Full Scale.
OPERATING RANGE / TURNDOWN RATIO: 0.5% to 100% Full Scale / 200:1.
MASS REFERENCE CONDITIONS STP): 70 °F & 14.696 PSIA (other available on request).
MAXIMUM INTERNAL GAS PRESSURE (STATIC): DPC07/17/37/47/57/67/77: 120 PSIG, DPC04/14: 50 PSIG
MAXIMUM INSTANTANEOUS  DIFFERENTIAL PRESSURE ACROSS DIFFERENTIAL SENSOR: DPC07/17/37/47/57/67/77: 12 PSID DPC04/14: 9.75 PSID
PROOF PRESSURE: DPC07/17/37/47/57/67/77: 145 PSIG; DPC04/14: 50 PSIG
VALVE TYPE: Normally Closed.
OPERATING TEMPERATURE: -10 to +60 ˚C (14 to 140 ˚F).
MOUNTING ATTITUDE SENSITIVITY: None.
RELATIVE GAS HUMIDITY RANGE: 0 to 100% (Non -Condensing).
INGRESS PROTECTION: IP40
ANALOG OUTPUT SIGNALS: Linear 0-5 Vdc (3000 ohms min. load impedance); Linear 0-10 Vdc (5000 ohms min. load impedance); Linear 4-20 mA (550 ohms maximum loop resistance) with power supply >= 14Vdc.
ANALOG SET POINT INPUT SIGNALS: Linear 0-5 Vdc, 0-10Vdc (100K input impedance). Linear 4-20mA (250 Ohm input impedance).
TRANSDUCER INPUT POWER: 12 to 26 Vdc, 150 mV maximum peak to peak output noise. Power consumption: 250 mA
maximum for DPC04/07/14/17, 300mA maximum for DPC37/47. 24 to 26 Vdc for DPC57/67/77
(Power consumption: 650 mA maximum) circuit board have built-in polarity reversal protection,
300mA (750mA for DPC57/67/77) resettable fuse provide power input protection.
DIGITAL OUTPUT SIGNALS 2 : Standard RS-232 or RS-485 (user selectable). Optional Modbus over isolated RS-485 transceiver.
**MATERIALS FLUID CONTACT: 316 stainless steel, 416 stainless steel, high temperature polyamide, alumina ceramic, poxy, silicone, glass, gold. Viton® O-rings

  • (1) Instruction Manual

Download

Note: Prices are not binding at any time subject to change without prior notice


  DPC MODEL 0 Item Selected
Image
Model
Product Name
Price
Available
Quantity
DPC Mass Flow Controller
Rp.58.716.500
1 Availability
  DPC MAX FLOW (Air) 0 Item Selected
  DPC MATERIAL 0 Item Selected
  DPC SEALS 0 Item Selected
  DPC CONNECTIONS 0 Item Selected
  DPC READOUT 0 Item Selected
  DPC POWER 0 Item Selected
  DPC SET POINT ANALOG INPUT SIGNAL 0 Item Selected
  DPC OUTPUT SIGNAL 0 Item Selected
  DPC DIGITAL INTERFACE 0 Item Selected
  DPC FLOW RANGE 0 Item Selected