  • Chauvin Arnoux OX5022B 2-Channels Analog, 20MHz Metrix Portable Oscilloscope

Chauvin Arnoux OX5022B 2-Channels Analog, 20MHz Metrix Portable Oscilloscope

Not yet rated Write a review
Chauvin Arnoux
Rp.49.715.860
Availability:
4 - 6 WEEKS
Product Code:
OX5022B
Brand:
Chauvin Arnoux
Update Terakhir:
04 Dec 2024
  • Free delivery

  • Money back guarantee

Share

Chauvin Arnoux OX5022B 2-Channels Analog, 20MHz Metrix Portable Oscilloscope. The Chauvin Arnoux Hand scope is an Oscilloscope which is shockproof, IP54 and fits comfortably in one hand. This ergonomic instrument is also equipped with a TFT colour screen and LED backlighting for precise data display. To make it simpler to use, intuitive pictograms and integrated multilingual help are available at all times.

  • Part Number: OX5022B
  • Number of channels : 2 totally-isolated channels
  • Bandwidth : 20 MHz
  • Optimized 3.5 inch colour LCD screen for maximum visibility
  • Multilingual interactive online help
  • Data recording and recovery on PC
  • Practical with its USB communication using the SCPI protocol
  • Stand alone, powered by NiMH rechargeable battery with USB charger

  • HUMAN-MACHINE INTERFACE:
  • Type of display : 3.5» colour TFT – Resolution 320x240 –LED backlighting
  • Display mode : 2,500 real acquisition points on screen
  • On-screen display of curves : 2 curves + 2 references + memory trace or mathematical calculation
  • Commands : Direct adjustments on front panel & on-screen menus via browser (main & secondary without «hidden menus»)
  • Interactive help function : 14 languages: French, English, German, Spanish, Italian, Swedish, Romanian, Russian, Finnish, etc.
  • OSCILLOSCOPE MODE:
  • Vertical deflection:
  • Bandwidth : 20 MHz 
  • Bandwidth limiter : 1,5 MHz, 5 kHz
  • Number of channels : 2 totally-isolated channels
  • Input impedance : 1 MΩ ±0.5%, approx. 17 pF
  • Maximum input voltage : 600 V CAT III – Derating -20 dB per decade from 100 kHz
  • Vertical sensitivity : 5 mV to 200 V/div
  • Horizontal deflection:
  • Sweep speed : 25 ns/div to 200 s/div –Roll mode from 100 ms to 200 s/div
  • Horizontal zoom : Zoom coefficient: x1, x2, x5
  • Triggering:
  • Mode : Automatic, triggered, one-shot & Triggered Roll
  • Type : Edge, pulse width (20 ns – 20 s)
  • Coupling : AC or DC (depending on coupling of triggering channel)), HF, LF or noise rejections
  • Sensitivity:  ≤1.2 divisions p-p up to 20 MHz
  • Digital memory:
  • Maximum sampling rate : 2 GS/s in ETS mode – 50 MS/s in one-shot mode on each channel
  • Vertical resolution : 9 bits
  • Memory depth : 2,500 points per channel
  • User memory : 2 MB for file storage: trace (.trc), text (.txt), configuration (.cfg), image files (.bmp)
  • GLITCH mode : Duration ≥20 ns – 1,250 Min/Max pairs
  • Display modes : Envelope, Averaging (Factors 2 to 64) and XY (vector)
  • Other functions:
  • MATH functions : Channel inversion, addition, subtraction, multiplication and division (adjustable scaling)
  • Cursor measurements : 2 cursors: V, T, dV, dt simultaneously – 4-digit display resolution
  • Automatic measurements : 19 time-based or level measurements and Phase measurement
  • MULTIMETER MODE:
  • General specificationss : 2 channels, 8,000-count display + min/max bargraph – Graphical recording of 2,700 measurements (5 min to 1 month)
  • Operating modes : Absolute or relative display (absolute, deviation, rel, rel%) – Monitoring (instantaneous, Min, Max, Avg)
  • AC, DC and AC+DC voltages : Ranges From 600 mV to 600 VRMS, 800 mV to 800 VDC –VDC Accuracy 1% Reading +20D –50 kHz bandwidth
  • Resistance : Range from 80 Ω to 32 MΩ - accuracy 2%R+10D –10 ms quick continuity test
  • Capacitance : Ranges from 5 nF to 5 mF – basic accuracy 2%R+10D
  • Other measurements : Frequency, rotation speed, 3.3 V diode test, temperature measurement (by K Thermocouple and infrared sensor)
  • POWER:
  • Measurements : Single-phase and balanced three-phase active power values (with or without neutral), simultaneous display of current – P
  • HARMONIC ANALYSER MODE:
  • Multi-channel analysis:  2 channels, 31 orders, frequency of fundamental from 40 to 450 Hz
  • GENERAL SPECIFICATIONS:
  • Screenshots : Up to 100 files in standard «.bmp» format, viewable on the instrument
  • PC communication : Isolated optical USB interface – «SX-Metro» PC application software available as an option
  • Power supply : 6 x LR6 batteries or 6 x AA NiMh rechargeable batteries – Battery life of up to 8.5 hrs
  • Safety / EMC : Safety as per IEC61010-1 Ed3 – 600 V CAT III – EMC as per EN61000-3, 2001 & EN61326-1, 2006
  • Mechanical specifications : 214 x 110 x 57 mm – 1.2 kg with batteries – moulded elastomer casing
  • Warranty : 3 years

  • (1) OX5022B - Portable Oscilloscope
  • (2) BNC-Banana adapters
  • (2) Sets of straight-elbowed moulded PVC banana leads 1.5 m long (red/black)
  • (2) Sets of red-black crocodile clips
  • (1) Quick Start Guide on paper (5 languages) / access to User’s Manual via QR Code
  • (2) Sets of red/black CAT IV 1000V test probes
  • (1) Jack-USB lead + USB WALLPLUG
  • (1) USB optical cable
  • (1) Bag

Download

Note: Prices are not binding at any time subject to change without prior notice


  Options 0 Item Selected
Image
Model
Product Name
Price
Available
Quantity
Chauvin Arnoux OX5022B 2-Channels Analog, 20MHz Metrix Portable Oscilloscope
OX5022B
Rp.49.715.860
4 - 6 WEEKS
Chauvin Arnoux OX5042B 2-Channels Analog, 40MHz Metrix Portable Oscilloscope
OX5042B
Rp.54.770.752
4 - 6 WEEKS