Chauvin Arnoux Scopix IV [OX 9062] 2-Ch, 100 MHz Metrix Handheld Digital Storage Oscilloscope

Not yet rated Write a review
Chauvin Arnoux
Rp.78.304.915
Availability:
4 - 6 WEEKS
Product Code:
OX 9062
Brand:
Chauvin Arnoux
Update Terakhir:
04 Dec 2024
  • Free delivery

  • Money back guarantee

Share

Chauvin Arnoux Scopix IV [OX 9062] 2-Ch, 100 MHz Metrix Handheld Digital Storage Oscilloscope. SCOPIX IV oscilloscopes are ideal for work in the field or in the lab. Pratical for all measurements in total safety, the OX 9062 is equipped with 2 totally-isolated channels with 60 MHz bandwith and a memory depth of 100 kpoints per channel, considerably increasing the available duration for recording. The OX 9062 oscilloscope is multifunction and has available all the analytical modes : Oscilloscope, multimeter, analyser, recorder and viewing of files recorded. The OX 9062 oscilloscope offers a genuine high performance thanks to its 12-bit converter with a vertical resolution of 0,0025%. In addition to its advanced trigger functions (pulse width, counting, delay), OX 9062 proposes 20 automatic measurements per channel linked to cursors for comprehensive analysis. OX 9062 benefits from standard and advanced "MATH" functions allowing users to define a mathematical function for each of the traces, along with vertical scaling and definition of the actual physical unit. Thanks to the real-time FFT function provided simultaneously with the waveform plus qualitative analysis of the harmonics, the distortion of a signals, the pulse response, it ensures effective, accurate diagnostics when searching for a source of noise in the logic circuits. The multi-channel, 8,000-count, 200 kHz TRMS digital multimeter measures the amplitudes, resistance, continuity, capacitance, frequency and temperatures, as well as performing component tests without changing the connections thanks to PROBIX. The multimeter mode is linked to the logger mode, allowing time/date-stamped recordings to be made automatically (N files of 100,000 measurements each with a 0.2 s interval between 2 acquisitions.). Power measurements are possible in this mode: single and three-phase power active reactive and apparent power plus the power factor. The multi-channel harmonic analyser mode is capable of displaying the first 63 orders for signals whose fundamental frequency is between 40 and 450 Hz. A .png screenshot is available in each of the modes and the reminder of all your recordings provides an unprecedented level of comfort for your diagnostics. All the means of communication are available to optimize your analyses: wired Ethernet and WIFI, USB and μSD. PROBIX plug-and-play accessories offer a quick implementation of the instrument with no risk of errors. The coefficients, scales and units of the sensors and the channel configuration are managed automatically and the probes and adapters are recognized as soon as they are connected.


  • Part Number: OX9062
  • Number of channels : 2 isolated channels
  • Bandwidth : 60 MHz
  • Functions as an oscilloscope, multimeter, harmonics analyser and data logger
  • Available in four models with differing bandwidths and number of isolated channels
  • Four modes: Oscilloscope, Multimeter, Analyser and Recorder
  • Trigger functions: pulse width, counting and delay
  • Delay mode: observe any event with the maximum resolution
  • Counting mode: count events before the trigger
  • Trigger functions allow the user to record all faults without recording data unnecessarily
  • Automatic measurements: view all 20 parameters of the signal for each channel
  • Use H and V cursors to view signals in greater detail
  • Perform direct comparisons between two traces and view the parameters with regards to their deviations by selecting ‘Reference Deviation Memory’
  • Math Functions: -/+/*/÷  as well as sine, cosine, exponential, logarithm and square root
  • Define a mathematic function for each of the traces
  • View all calculated traces
  • FFT function: measure the different harmonics and/or distortion of signals, analyse the pulse response and search for noise in the logic circuits
  • FFT has two modes, linear or logarithmic (dB)
  • Use cursors to conduct precise measurements of frequency lines
  • Autoset function scales the spectrum
  • 80dB dynamic range and 12-bit/ 2.5 GS/s conversion
  • Perform harmonic analysis on all isolated channels up to the 63rd order as required by the EN 50160 standard
  • Preselect fundamental frequency (choose from 50Hz, 60Hz and 400Hz)
  • View the phase of the harmonic in relation to the fundamental frequency
  • View RMS level, harmonic distortion and harmonic frequency
  • View  the harmonic analysis of all the isolated functions simultaneously
  • 8000-count, true-RMS digital multimeter
  • AC/DC voltage
  • AC/DC current
  • Resistance
  • Continuity
  • Capacitance
  • Component tests
  • Single-phase power
  • Three-phase power on a balanced network without neutral
  • Three-phase power on a balanced network with neutral
  • 3-wire three-phase power (2-wattmeters method)
  • Use a Pt100/ Pt1000 sensor or K thermocouple to measure temperature
  • ‘Plug and Play’ accessories are automatically detected, calibrated and powered by the oscilloscope
  • Recorder mode allows the oscilloscope to record data gathered when in Multimeter mode
  • Record data over a duration of 2 seconds to 1 month
  • Set data acquisition intervals as short as 40µS
  • Display signal traces as references at the push of a button
  • View comparisons and measurement deviations
  • Save information in various formats for easy exportation
  • Capture screenshots in PNG formats
  • The front panel can be used to send documents to print and transfer and delete files in the file manager
  • Recall curves and screenshots from the instrument’s memory
  • Communicate with a PC, tablet or smartphone via an Ethernet or USB connection
  • Ethernet LAN network with an integrated DHCP server may be used to activate a Wi-Fi radio link
  • Save information to a µSD card
  • Record, recall and load configurations via USB connection
  • When connected to a PC via the ScopeNet application, USB or Ethernet connection the instrument can be operated remotely and programmed using SCPI commands
  • 7-inch WVGA wide colour TFT touchscreen with a resolution of 800 x 480dpi, and manual or automatic brightness
  • View colour-coded channels and parameters via the display
  • Pictograms for easy access to particular functions
  • IP54
  • Adjustable transport strap
  • Stand with Kensington locking system
  • Ergonomic, versatile, comprehensive, easy-to-use instrument ideal for a variety of maintenance applications

  • HUMAN-MACHINE INTERFACE: 
  • Type of display: 7‘’ WVGA colour TFT LCD touch screen, 800x480 – LED backlighting (adjustable standby mode)
  • Different display mode: 2,500 real acquisition points on screen - Vectors with interpolation
  • Display of curves on screen: 4 curves + 4 references – Split Screen & Full Screen modes
  • Screen commands: Touch screen  – ANDROID-type icons and graphical commands – customizable channel colours
  • Choice of language: 15 complete languages, menus & online help
  • OSCILLOSCOPE MODE:
  • Vertical deflection:
  • Bandwidth: 60 MHz: 15 MHz, 1.5 MHz or 5 kHz bandwidth limiter
  • Number of channels: 2 isolated channels
  • Input impedance: 1 MΩ ± 0.5% , approx. 12 pF
  • Maximum input voltage: 600 V / CAT III (1,000V per Probix) – from 50 to 400 Hz – Probix safety connectors
  • Vertical sensitivity: 16 calibres from 2.5 mV to 200 V/div and up to 156 µV/div in vertical zoom mode (12-bit converter) – Accuracy ± 2%
  • Vertical zoom: "One Click Winzoom" mode (12-bit converter and direct graphical zoom on screen) – x 16 max.
  • Probe factor (non-Probix): 1 / 10 / 100 / 1,000 or any scaling – definition of measurement unit
  • Horizontal deflection:
  • Sweep speed: 35 calibres from 1 ns/div to 200 s/div., accuracy ± [50 ppm + 500 ps] – Roll mode from 100 ms to 200 s/div
  • Horizontal zoom: "One Click Winzoom" system (direct graphical zoom on screen) x 1 to x 5 or x 100 – storage 100 kpts/channel
  • Triggering:
  • Mode: On all the channels: automatic, triggered, one-shot, auto level 50%
  • Type: Edge, pulse width (16 ns-20 s), delay (48 ns to 20 s), counting (3 to 16,384 events); Continuous adjustment of Trigger position
  • Coupling: AC, DC GND, HFR, LFR, noise – Level and Hold-Off adjustable from 64 ns to 15 s
  • Sensitivity: ≤ 1.2 division p-p up to 300 MHz
  • Digital storage:
  • Maximum sampling rate: 2.5 GS/s in one-shot mode on each channel (100 GS/s max. in ETS mode)
  • Vertical resolution: 12 bits (vertical resolution 0.025 %)
  • Memory depth: 100 kpts per channel and file viewer in the manager
  • User storage File management:
  • Internal = 1 GB to store the files: trace, text, configuration, math functions, System memory: .pdf print files, .png image files
  • + high-capacity removable µSD-Card: SD 2 GB, SDHC 4-32 GB and SDXC > 32 GB
  • GLITCH mode: Duration ≤ 2 ns – 500,000 Min/Max pairs
  • Display modes: Envelope, vector, accumulation-, averaging (factors 2 to 64) – XY (vector) and Y(f)=FFT
  • Other functions:
  • AUTOSET: Complete in under 5 s, with recognition of the channels – Frequency > 30 Hz
  • FFT analyser & MATH functions: 2,500-point FFT (Lin or Log) with measurement cursors – Functions + , - , x , / and mathematical function editor
  • Cursors: 2 or 3 cursors: simultaneous V and T with AUTO measurement: T1, T2, Dt, 1/Dt, dBV, Ph
  • Automatic measurements: Simultaneously with waveform, 20 automatic measurements per channel and on the 4 channels simultaneously with scroll
  • MULTIMETER MODE:
  • General specifications: 2 or 4 channels – 8,000 cts min/max/frequency/relative – TRMS – Time/date-stamped graphical recording in logger mode
  • AC, DC and AC + DC voltages: 600 mV to 600 VRMS, 800 mV to 800 VDC – VDC accuracy +/- (0.5 % + 25 D) – 200 kHz bandwidth
  • Resistance: 80 Ω to 32 MΩ – accuracy 0.5%R+ 25D – Quick continuity test < 10 ms
  • Other measurements: Temperature (HX0035 = KTC, HX0036 = Pt100) / Capacitance 5nF to 5mF / Frequency 200 kHz / Diode test 3.3 V
  • Single and three-phase power: Active, Reactive and Apparent power values plus Power Factor simultaneously with the U & I measurements
  • HARMONIC ANALYSER MODE:
  • Multi-channel analysis: 2 or 4 (depending on model), 63 orders, fundamental frequency 40 to 450 Hz in auto or manual mode
  • Simultaneous measurements: Total Vrms, THD and selected order (% fundamental, phase, frequency, Vrms)
  • LOGGER MODE: 
  • Acquisition: Duration: 20,000 s – Interval: 0.2 s – Files: 100,000 measurements
  • GENERAL SPECIFICATIONS: 
  • Configuration memories: Not limited according to device - variable file sizes
  • Printing: Network printing via Ethernet/Wifi in .png format
  • PC communication – software link: Ethernet (100 baseT), WiFi-USB (device, 12 Mbs) – "ScopeNet" application software for PC
  • Software: PC: Ethernet and USB, ScopeNet (remote control, data recovery, cursors and automatic measurements); Android tablet – ScopeAdmin Fleet Administration utility
  • Mains power supply: Li-Ion rechargeable battery (6,900mAH-40 Wh) – Battery life of up to 8 hrs – Adjustable standby mode; Adapter / 2-hour fast charger, universal 98-264 V / 50/60 Hz)
  • Safety / EMC: Safety as per IEC 61010-2-30, 2010 – 600 V CAT III / 1000 V CAT II – EMC as per EN61326-1, 2010
  • Mechanical specifications: 292.5 x 210.6 x 66.2 mm – 2.1 kg with batteries – IP54 protection

  • (1) 9062 - Digital Storage Oscilloscope
  • (1) Carrying Bag
  • (1) PA40W-2 Mains Power Pack/Charger
  • (1) 2P EURO Mains Power Cable
  • (1) Li-Ion battery pack
  • (1) Stylus
  • (1) Ethernet Cable
  • (1) USB Cable
  • (2) Safety Leads (red, black)
  • (2) Ø 4 mm Test Probes (red, black)
  • (1) Voltage Probes (2 or 4 depending on model)
  • (1) μSD card (8 GB)
  • (1) USB/ μSD adapter
  • (1) Hand strap
  • (1) PROBIX BANANA
  • (1) USB Installation Procedure for use of ScopeNet Data Export Software on CD-ROM
  • (1) PDF user’s manual (5 languages)
  • (1) Start-up Guide on Paper
  • (1) Safety Datasheet in 20 Languages

Download

Note: Prices are not binding at any time subject to change without prior notice


  Options 0 Item Selected
Image
Model
Product Name
Price
Available
Quantity
Chauvin Arnoux Scopix IV [OX 9062] 2-Ch, 100 MHz Metrix Handheld Digital Storage Oscilloscope
OX 9062
Rp.78.304.915
4 - 6 WEEKS
Chauvin Arnoux Scopix IV [OX 9102] 2-Ch, 100 MHz Metrix Handheld Digital Storage Oscilloscope
OX 9102
Rp.113.834.154
4 - 6 WEEKS
Chauvin Arnoux Scopix IV [OX 9104] 4-Ch, 100 MHz Metrix Handheld Digital Storage Oscilloscope
OX 9104
Rp.138.012.276
4 - 6 WEEKS
Chauvin Arnoux Scopix IV [OX 9304] 4-Ch, 300 MHz Metrix Handheld Digital Storage Oscilloscope
OX 9304
Rp.138.024.742
4 - 6 WEEKS
  Accessories 0 Item Selected