• Omega TLC Series [TCL-165S-D] Dry Block Calibrator -31 to 329°F (-35 to 165°C)

Omega TLC Series [TCL-165S-D] Dry Block Calibrator -31 to 329°F (-35 to 165°C)

Not yet rated Write a review
Rp.171.100.000
Availability:
4 - 6 WEEKS
Product Code:
TCL-165S-D
Brand:
OMEGA Engineering
  • Free delivery

  • Money back guarantee

Share

Omega TLC Series [TCL-165S-D] Dry Block Calibrator -31 to 329°F (-35 to 165°C). The Omega hot/cold dry block calibrator model TCL-165S-D has all the features of the TCL-650S-D plusa cooling cycle that allows stable temperature calibration down to -35°C(-31°F) and up to 165° (329°F). The internal sensor is burned specially aged until it is virtually drift free. Digital electronics and control algorithms assure long term accuracy so you are always aware of the conditions in the calibrator.

A temperature calibrator today needs to be versatile and meet a wide range of requirements. It should be an easily portable device to cope with frequently changing operation locations, as in multiple test bays or in production locations. A calibrator should also be equally suitable for stationary use in the measurement lab or in testing and inspection. To meet these demands, these calibrators are lightweight and easy-to-use at each site. Five temperature calibrators are available to cover the range from -35 to 650°C (-31 to 1202°F) and wet or dry calibration requirements.

  • Dry Block Calibrator: TCL-650S-D, ambient to 650°C (1202°F)
  • Dry Block Calibrator: TCL-165S-D, -35 to 165°C (-31 to 329°F)
  • Micro Bath Calibrator: TCL-M165S-B, -35 to 165°C (-31 to 329°F)
  • Micro Bath Calibrator: TCL-M255S-B, ambient to 255°C (491°F)
  • Multi-function Calibrator: TCL-3M165E, Dry Bath, Micro Bath, Infrared Blackbody, and Surface Temperature

Why calibrate? Temperature sensors are subject to mechanical, thermal and chemical stresses. This results in a drift the longer the sensors are in use. Only the regular calibration of the sensors provides information on the difference between the actual temperature and the measured temperature and makes the specific drift visible. This data can be critical to maintaining a stabile process operation. OMEGA™ Dry block calibrators and micro bath calibrators are one of the best means to check and calibrate a wide range of temperature measuring instruments and temperature sensors. Mechanical, electro-mechanical or electronic measurement equipment can be checked with ease. These compact and durable calibrators are easy to transport, user friendly and offer all the features required for the specific test.