Fluke 725Ex [FLUKE-725EX] Intrinsically Safe Multifunction Process Calibrator

Not yet rated Write a review
Fluke
Rp.124,500,000
Availability:
4 - 6 WEEKS
Product Code:
FLUKE-725EX
Brand:
Fluke
Update Terakhir:
13 May 2017
  • Free delivery

  • Money back guarantee

Tanyakan Pada Ahlinya

Pakar Teknologi Kami Siap Membantu!

(62) 021-53167044 | 0812-83861970 | 0812-9915277

Email Us

Share

The Fluke 725Ex intrinsically safe multifunction process calibrator is powerful yet easy-to-use. Combined with one of the Fluke 700PEx pressure modules, the Fluke 725Ex is able to calibrate almost any process instrument likely to need service in an area where explosive gases may be present.

The Fluke 725Ex intrinsically safe multifunction process calibrator meets ATEX II 1G EEx ia IIB 171 °C KEMA 04ATEX 1303X safety standard and I.S. Class I, Division 1 Groups B-D, 171 °C compliance. It's rugged and reliable for field use and has a simple, push-button user interface and can store frequently-used test setups for later use.

The Fluke 725Ex multifunction process calibrator can be used to measure volts dc, mA, RTDs, thermocouples, frequency and ohms. It can source or simulate volts dc, mA, thermocouples, RTDs, frequency and ohms. The Fluke 725Ex has a two channel simultaneous source and measure capability allowing for the calibration of transmitters. Used with the Fluke 700PEx intrinsically safe pressure modules, the Fluke 725Ex can take pressure measurements up to 3,000 psi/200 bar.


There are no reviews for this product.

Write a review

  • Support flow meter testing with frequency and CPM functions
  • Perform fast linearity tests with auto- step and auto-ramp features
  • Power transmitters during test using loop supply with simultaneous mA measurement
  • Store frequently used test setups for later use
  • Backlight lets you work in poor light
  • Large battery capacity of four AA cells
  • Battery door for easy changes
  • Also available Fluke 725EX Intrinsically safe model


Voltage DC:
  • 30.000V: 0.02%+ 2 counts (upper display)
  • 10.000 V: 0.02%+ 2 counts (lower display)
  • 90.00 mV: 0.02%+ 2 counts
  • -10.00 mV to 75.00 mV: 0.025 % + 1 count (via TC connector)
Current DC:
  • 24.000 mA:  0.02%+ 2 counts
Resistance: 
  • 0.0 to 400.0 Ω: 0.1Ω (4-wire), 0.15Ω (2- and 3-wire)
  • 401 to 1500 Ω: 0.5Ω (4-wire), 1Ω (2- and 3-wire)
  • 500 to 3200 Ω: 1Ω (4-wire), 1.5Ω (2- and 3-wire)
Frequency:
  • 2.0 to 1000.0 CPM: 0.05 % + 1 count
  • 1.0 to 1100.0 Hz: 0.05 % + 1 count
  • 1.00 to 10.00 kHz: 0.05 % + 1 count
  • Sensitivity: 1 V peak-to-peak-minimum
Pressure:
  • Accuracy from 0.025% of range using any of 8 intrinsic safe pressure modules. (for detailed specifications refer to pressure modules in options and accessories)
  • Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
Source Accuracy:
Voltage DC:
  • 100.00 mV: 0.02%+2 counts
  • 10.000 V: 0.02%+2 counts
  • -10.00 mV to 75.00 mV: 0.025 % + 1 count (via TC connector)
Current DC:
  • 24.000 mA (Source): 0.02%+ 2 counts
  • 24.000 mA (Simulate): 0.02%+ 2 counts
Resistance:
  • 15.0 to 400.0 Ω: 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA)
  • 401 to 1500 Ω: 0.5 Ω(excitation current 0.05 to 0.8 mA)
  • 1500 to 3200 Ω: 1 Ω(excitation current 0.05 to 0.4 mA)
Frequency:
  • 2.0 to 1000.0 CPM: 0.05%
  • 1.0 to 1100.0 Hz: 0.05%
  • 1.00 to 10.00 kHz: 0.25%
  • Waveform: 5 V p-p squarewave, -0.1 V offset
RTDs and Thermocouples:
  • Measure Accuracy:
  • NI-120: 0.2 °C
  • PT-100 (385): 0.33 °C
  • PT-100 (393): 0.3 °C
  • PT-100 (JIS): 0.3 °C
  • PT-200 (385): 0.2 °C
  • PT-500 (385): 0.3 °C
  • PT-1000 (385): 0.2 °C
  • Resolution:0.6°C
  • J: 0.7 °C
  • K: 0.8 °C
  • T: 0.7 °C
  • E: 1.8 °C
  • R: 1.5 °C
  • S: 1.4 °C
  • B: 0.7 °C
  • L: 0.75 °C
  • U: 0.9 °C
  • N: J, K, T, E, L, N, U: 0.1 °C, 0.1 °F B, R, S: 1 °C, 1 °F
  • Resolution: 0.6°C
  • XK: 1.2°C
  • BP
Source Accuracy:
  • NI-120 : 0.2 °C
  • PT-100 (385) : 0.33 °C
  • PT-100 (393): 0.3 °C
  • PT-100 (JIS): 0.3 °C
  • PT-200 (385): 0.2 °C
  • PT-500 (385): 0.3 °C
  • PT-1000 (385): 0.2 °C
  • Resolution: 0.1 °C
  • Note: Accuracy stated for 4-wire measurement
  • J: 0.7 °C
  • K: 0.8 °C
  • T: 0.8 °C
  • E: 0.8 °C
  • R: 1.4 °C
  • S: 1.5 °C
  • B: 1.4 °C
  • L: 0.7 °C
  • U: 0.75 °C
  • N: 0.9 °C
  • Resolution: J, K, T, E, L, N, U: 0.1 °C, B, R, S: 1 °C
  • XK: 0.6°C
  • BP: 1.2°C
Specifications
Ramp Functions: 
  • Source functions: Voltage, current, resistance, frequency, temperature
  • Ramps: Slow ramp, Fast ramp, 25% step-ramp
Loop Power Function: 
  • Voltage: 12 V
  • Accuracy: 10%
  • Maximum current: 22 mA, short circuit protected
Step Functions:
  • Source functions: Voltage, current, resistance, frequency, temperature
  • Steps: 25% of range, 100% of range
Safety Specifications:
  • Agency Approvals: ATEX II 1 G Ex ia IIB 171°C; I.S. Class I, Division 1 Groups
Mechanical & General Specifications: 
  • Size: 130 x 236 x 61 mm (5.188" x 9.291" x 2.402")
  • Weight: 0.85 kg (1.874 lbs.)
  • Batteries: 4 AA Alkaline batteries
  • Warranty: 3 years
  • Battery Replacement: Separate battery compartment, accessible without breaking calibration seal
  • Side port connections: Pressure module connector

  • (1) TL75 Test Leads
  • (1) Test Clip Set
  • (1) Pair of stackable test leads
  • (1) Product Overview Manual
  • (1) Users Manual
  • (1) CD-Rom
  • (1) CE and CSA markings

Download

Note: Prices are not binding at any time subject to change without prior notice