Multiple Product

have been added to your cart

There Are items in your cart.

Cart Subtotal: $xxx.xx

Go to checkout

BK Precision DAS220 [DAS-220V] Portable 10-Channel Data Recorder without Battery, 230VAC Line Input

Not yet rated Write a review
BK Precision
Rp.65,663,589
Availability:
4 - 6 WEEKS
Product Code:
DAS220-230V
Brand:
BK Precision
Update Terakhir:
15 Nov 2024
  • Free delivery

  • Money back guarantee

Share

BK Precision DAS220 measures parameters commonly found in process applications including voltage, temperature, current, resistance, frequency and pulse. It includes 10 built-in universal analog channels with convenient screw input terminals for portability. This recorder was developed by B&K Precision’s subsidiary Sefram in France, which specializes in the design and manufacture of data acquisition instruments, field strength meters, and other test and measurement instruments. Measurement results can be viewed graphically and numerically on the 10-inch color touch screen and saved to internal solid-state memory or an external USB memory stick. Icon-driven menus make the instrument easy to navigate. The free DasLab Windows PC software allows users to remotely control and configure the recorder, transfer logging results and configuration files, and view live data in graphical or numerical format on the PC.

  • Part Number: DAS-220V-230V
  • Power Supply : 15 V / 4 A max with main adapter (100 / 240 VAC)
  • Portable 10-Channel Data Recorder without battery
  • Wide 10-inch touchscreen TFT display
  • 10 built-in universal analog inputs
  • Versatile temperature measurements supporting thermocouples and Pt100 / Pt1000 temperature sensors
  • Measure voltage to ± 100V, resistance to 10 kOhm and current (with optional shunt)
  • 16-bit vertical resolution
  • 32 GB internal solid state memory
  • 12 logic input/output channels
  • 4 timing logic input channels for pulse count, frequency and PWM measurements
  • Free DasLab operating software
  • Applications:
  • Temperature logging with thermocouples and platinum resistance temperature sensors
  • Voltage measurements down to ± 0.5 mV range
  • 4-20 mA current loop measurements
  • Frequency, pulse totalization and pulse  rotation measurements, which can be expressed in RPM (rotations per minute)

  • Analog Channels:
  • Analog Input Channels: 10 integrated channels
  • DC Voltage:
  • Ranges: ± (0.5, 1, 2.5, 5, 10, 25, 50, 100) mV± (0.5, 1, 2.5, 5, 10, 25, 50, 100) V
  • Maximum input Voltage: 100 V DC
  • Accuracy: 0.1% of the full scale ±10 µV
  • Temperature with Thermocouples:
  • Sensors Range by Type (Cold junction compensation: ±0.5 °C):
  • J: -210 °C to 1200 °C
  • K: -250 °C to 1370 °C
  • T: -200 °C to 400 °C
  • S: -50 °C to 1760 °C
  • B: 200 °C to 1820 °C
  • E: -250 °C to 1000 °C
  • N: -250 °C to 1300 °C
  • C: 0 °C to 2320 °C
  • L: -200 °C to 900 °C
  • Temperature with Pt100 and Pt1000:
  • Current: 1 mA (Pt100), 100 µA (Pt1000)
  • Range: -200 °C to 850 °C
  • Measurements: 2 and 3 wires
  • Accuracy (at 20 °C): 0.3 °C ±0.1% of reading
  • Compensated Resistance: 2 wires 30 Ω max.; 3 wires 50 Ω max
  • Resistance:
  • Ranges: 1 kΩ and 10 kΩ
  • Accuracy: 1 Ω (range 1 kΩ) and 10 Ω (range 10 kΩ)
  • Logic Channels:
  • Logic Input/Output:
  • Number of Channels: 12
  • Maximum Permitted Voltage: 24 V Cat I
  • Input Impedance: 4.7 kΩ
  • Sampling Rate: 1 ms max.
  • Timing Input:
  • Number of Channels: 4 (K1 to K4)
  • Maximum Permitted Voltage: 24 V Cat I
  • Input impedance: 4.7 kΩ
  • Sampling Rate: 1 ms max.
  • Pulse Counter: 0 to 10 Million, accuracy 0.1%
  • Frequency Measurement: 1 Hz to 10 kHz, accuracy 0.1%
  • PWM Measurement: 100 Hz to 2 kHz, accuracy 0.1%
  • Alarm Output:
  • Number of Channels: 4 Alarms (A, B, C, D)
  • Output Level: 0 to 5 V
  • Acquisition System:
  • Resolution: 16 bit
  • Acquisition System: Scan, one sample per channel
  • Sampling Interval:
  • V >50 mV: 1 ms to 20 min
  • V ≤50 mV, thermocouples and Pt100 / Pt1000: 2 ms to 20 min
  • Trigger: Date, delay, threshold, combination of thresholds (and/or), word on logic channels (and, or, slope, level)
  • Pre-trigger: Variable from 0 to 100k samples
  • General:
  • Internal Flash Drive Size: 32 GB
  • Maximum File Size: 2 GB
  • Operating Temperature: 0 °C to 40 °C, 80% RH (no condensation)
  • Storage Temperature:  -20 °C to 60 °C
  • Display: 10” TFT touchscreen LCD, backlit, 1024 x 600 dots
  • Power Supply: 15 V / 4 A max with main adapter (100 / 240 VAC)
  • Interfaces: 2 x USB host, LAN (10/100 base-T with RJ45 socket)
  • Battery (-BAT): Non removable, Lithium-ion
  • Typical Battery Life (-BAT): 15 hours with standby mode, 10 hours without stand-by mode
  • Safety Cat I 100 V, according to IEC61010-1
  • Weight DAS220: 3.3 lbs (1.5 kg)
  • DAS220-BAT:  4.5 lbs (2 kg)
  • Dimensions (W x H x D): 2.6” x 11.7” x 6.9” (66 x 298 x 176 mm)

  • (1) DAS220 - 10-Channel Data Recorder
  • (1) Main adapter 100 / 240 V
  • (1) 25 pin male connector (1) and backshell
  • (1) 10 input connectors
  • (1) Shoulder strap
  • (1) Stylus
  • (1) Soft wipe
  • (1) Screwdriver
  • (1) Calibration certificate and test report

Note: Prices are not binding at any time subject to change without prior notice


  Options 0 Item Selected
Image
Model
Product Name
Price
Available
Quantity
BK Precision DAS220 [DAS220-BAT-230V] Portable 10-Channel Data Recorder With Battery, 230VAC Line Input
DAS220-BAT-230V
Rp.71,296,645
4 - 6 WEEKS
  Accessories 0 Item Selected