HANNA Instruments HI-5222 [HI5222-02] Research Grade pH / ORP / ISE / Temperature Benchtop Meter

Not yet rated Write a review
Rp.27.600.000
Availability:
2 - 4 WEEKS
Product Code:
HI5222-02
Brand:
Hanna Instruments
Update Terakhir:
13 May 2017
  • Free delivery

  • Money back guarantee

Share

The HI5222-02 is an advanced research grade dual channel benchtop pH/ISE/mV meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity. The HI5222-02 is rich in features including 5 point calibration, selectable resolution, data logging, alarm limits, comprehensive GLP, and much more. It retains simplicity with both dedicated key for routine operation and virtual keys that guide the user through setup options.

The HI5222-02 ensures confidence in measurements with the exclusive Hanna Instruments CAL Check feature that alerts the user to potential problems during calibration including if the buffer is contaminated or the probe needs to be cleaned.
The HI5222 is an advanced research grade benchtop pH/mV/ISE dual channel meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity.

The HI5222-02 features two galvanically isolated BNC connections for use with the expansive line of pH, ISE and ORP electrodes that Hanna Instruments offers. The meter is supplied with the HI1131B glass body, double junction, combination pH electrode that operates over a wide range of temperature from 0 to 100ºC.   All readings are automatically compensated for temperature variations with the separate HI7662-T temperature probe that is included.

As a pH meter, the HI5222-02 can be calibrated up to five points with eight preprogrammed buffers or five custom buffers. The HI5222-02 features Hanna’s exclusive CAL Check™ to alert the user of potential problems during the pH calibration processsuch as “Electrode Dirty/Broken” and “Buffer Contaminated.” The overall probe condition based on the offset and slope characteristic of the electrode is displayed as a percentage after calibration is complete.

As an ISE meter, the HI5222-02 can be calibrated up to five points with a choice of seven fixed standards or five user-defined standards in any concentration unit. The calibration data including date, time, standards used and slope can be viewed at any time along with the current measurement by selecting the Good Laboratory Practice (GLP) display option.

Three selectable logging modes are available: automatic, manual and AutoHold logging. Up to 100,000 data points per channel can be recorded in 100 lots, 50,000 records max/lot and exported to a computer for data review and storage.