Graphtec GL840 [GL840-M] 20-Channel Thermocouple/Voltage Midi Logger

Not yet rated Write a review
Graphtec
Rp.65.053.000
Availability:
4 - 6 WEEKS
Product Code:
GL840-M
Brand:
Graphtec
Update Terakhir:
13 May 2017
  • Free delivery

  • Money back guarantee

Share

The Standalone System
The Graphtec GL840M is a high quality 20 channel datalogger that is expandable up to 200 total channels. Each channel is isolated. This unit is suitable for many applications including temperature measurement with multiple channels. The built in 7 inch color display provides an intuitive data viewing experience. Although this system is designed as a standalone unit, it can be connected to a PC if needed. Communicate with up to (5) GL100 units with B-568 Wifi module.

Multifunction analog input ports
The GL840M has been designed with an extremely isolated input system ensuring that all signals are left unaffected by outside channel noise. With this capability, this system can be used for a variety of applications including voltage, humidity, temperature, pulse and logic.
The GL840M comes standard with 20 analog input channels but it is easily expandable up to 200 channels by adding the optional 20 channel extension terminal base (B-566) and other input terminal units (B-564 or B-565).

  • 20 analog input channels, expandable to 200
  • 4 discrete input channels
  • 4 discrete alarm outputs
  • Optional WiFi wireless operation (Order B-568)
  • Communicate with up to (5) GL100 units with B-568 Wifi module
  • Flexible triggering
  • Built-in, 7-inch color display
  • Built-in Web server operation for remote operations
  • Removable SD memory support up to 32 GB capacity
  • Operates either stand-alone or PC-connected

  • Number of analog input channels: 20 channels in standard configuration, Expandable up to 200 channels
  • Number of analog input terminals: Up to 10 terminals (20 channels / terminal), standard config: 1
  • Type of analog input terminal: Multi-input type, Withstand-voltage type
  • Port for digital sensor: 1 port for the sensor/input terminal/adapter of the GL100
  • External input/output *1: Input *2: Trigger or Sampling (1 channel), Logic/Pulse (4 channels); Output *3: Alarm (4 channels)
  • Sampling interval: 10ms to 1 hour (10ms to 50ms: voltage only) *4, External signal
  • Time scale of waveform display: 1 sec. to 24 hour / division
  • Trigger,Alarm functions:
  • Trigger action: Start or stop capturing data by the trigger
  • Repeat action: Off, On (auto rearmed)
  • Trigger source: Start: Off, Measured signal, Alarm, External, Clock, Week or Time; Stop: Off, Measured signal, Alarm, External, Clock, Week or Time
  • Condition Settings:
  • Combination: OR or AND
  • Analog signals: Rising (High), Falling (Low), Window-in, Window-out
  • Logic signal: Pattern (combination of each input signal in high or low)
  • Pulse (number of count): Rising (High), Falling (Low), Window-in, Window-out
  • Alarm output: Outputs a signal when an alarm condition occurs in the input signal *5
  • Pulse input function:
  • Rotation count (RPM) mode: Counts the number of pulses per sampling interval and converts to rpm (rotations per minute), Number of pulses for one rotation can be set to 50, 500, 5000, 50k, 500k, 5M, 50M, 500M rpm/F.S. (rpm./Full Scale)
  • Accumulating count mode: Accumulates the number of pulses from the start of measurement 50, 500, 5000, 50k, 500k, 5M, 50M, 500M C/F.S. (Counts/Full Scale)
  • Instant count mode: Counts the number of pulses per sampling interval 50, 500, 5000, 50k, 500k, 5M, 50M, 500M C/F.S. (Counts/Full Scale)
  • Calculation functions:
  • Between channels: Addition, Subtraction, Multiplication, and Division for analog input
  • Statistical: Select two calculations from Average, Peak, Maximum, Minimum, RMS
  • Search function: Search for analog signal levels, values ​​of logic or pulse or alarm point in captured data
  • Interface to PC:
  • Ethernet (10 BASE-T/100 BASE-TX), USB (Hi-speed), WLAN (using B-568 option)
  • Storage devices:
  • Media: 4 GB Internal Memory SD memory card (Support SDHC, up to 32 GB). Memory card not included
  • Saved contents: Captured data, Setting conditions, Screen copy
  • Capture mode:
  • Modes: Normal, Ring, Relay
  • Ring: Saves the most recent data (Number of capturing data: 1000 to 2000000 points) *7
  • Relay: Saves data to multiple files without losing data until chest capturing is stopped
  • Replay data:
  • Replays captured data that was saved in the GL840 (in GBD or CSV format)
  • Scaling (Engineering unit) functions:
  • Measured value can be converted to specified engineering units
  • Analog voltage: Converts using four reference points (gain, offset)
  • Temperature: Converts using two reference points (offset)
  • Pulse count: Converts using two reference points (gain)
  • Actions during data capture:
  • Displaying past data (using dual display mode (Current + Past data))
  • Hot-swapping the SD memory card
  • Saving data in between cursors
  • Displays:
  • Size : 7-inch TFT color LCD (WVGA: 800 x 480 dots)
  • Language: English, French, German, Chinese, Korean, Russian, Spanish, Japanese
  • Information *8: Waveform in Y-T with digital values, Waveform only, Digital values, Digital values ​​and statistical values
  • Operating environment:
  • 0 to 45 ºC, 5 to 85 % RH (non condensed) (When operating with battery pack 0 to 40 ºC, charging battery 15 to 35 ºC)
  • Power source:
  • AC adapter: 100 to 240 V AC, 50/60 Hz (1 pc of adapter is attached as standard accessory)
  • DC power: 8.5 to 24 V DC (DC drive cable (option B-514) is required)
  • Battery pack: Mountable two battery packs (battery pack (option B-517): 7.2V DC, 2900mAh)
  • Power consumption *9: Max. 38VA
  • External dimensions (W x D x H: in mm, Excluding projections: Approx. 240 x 158 x 52.5
  • Weight*10: Approx. 1010g
  • *1 Input/Output cable for GL (option B-513) is required to connect the signal.
  • *2 Input signals;
  • Voltage range: Up to 24V (common ground)
  • Signal type: Voltage, Open collector, Contact (relay)
  • Threshold: Approx. + 2.5 V (Hysteresis: Approx. 0.5V (2.5V to 3V))
  • *3 Output signal: Open collector (pull-up to 5V by 10kΩ resistor)
  • Voltage: Max. 30V,
  • Current: Max. 0.5A,
  • Collector dissipation: Max. 0.2W
  • *4 Minimum interval varies by number of channels used.
  • *5 Output ports can be specified in each input channel.
  •  *7 Size of the capture data will be limited to 1/3 of available memory.
  • *8 Display mode is switched every time the dedicated key is pressed. In magnified digital value mode, the displayed channel number can be specified. In the waveform display mode, the changing of the time scale will be effective from the point of the next displayed data.
  • *9 Rating under maximum power consumption using the AC adapter, with LCD display on, and battery pack(s) being charged.
  • *10 Excludes AC adapter and battery pack.
  • Software specifications for PC:
  • Supported OS: Windows 8.1, 8, 7, Vista (32/64-bit edition)
  • Supported devices: GL840 (USB, Ethernet, WLAN), GL100 (USB, WLAN)
  • Functions: Control the GL series, Real-time data capture, Replay data, and Data format conversion
  • Supported units & channels: Up to 1000 channels in total, Up to 4 groups (number of units is limited by model)
  • Settings control: Input condition, Capturing condition, Trigger/Alarm condition, Report, etc.
  • Capturing data: Saved to PC Saves captured data in real time (in GBD binary or CSV format)
  • Saved to GL unit: Saves to the SD memory card (in GBD binary or CSV format)
  • Displayed information: Y-T waveform, Digital values, Report, X-Y graph (specified period of data, data reply only), Two displays for the current and past data, and Statistical calculation
  • File operation: Converting data format to CSV from GBD binary, merge multiple data files in the time axis or as an additional channel
  • Warning function: Send e-mail to the specified address when the alarm occurs
  • Statistical calculation: Maximum, Minimum, and Average during capturing data
  • Report function: Creates the daily or monthly report automatically
  • Software specifications for Smart devices:
  • Model name: GL-Connect
  • Supported OS: Android 4.1 to 4.4, iOS 7/8
  • Supported devices: GL840 (WLAN), GL100 (WLAN)
  • Functions: Control the GL series, Display measured data in waveform or digital value
  • Supported units: Up to 10 units
  • Settings control: Start/Stop, Sampling interval
  • Capturing data: Saves captured data in the GL main body (data cannot be saved in the smart device)
  • Displayed information Data captured in real time by digital value, Replay the data stored in the GL body by the waveform
  • Wireless LAN unit (option) specifications:
  • Model number: B-568
  • Supported devices: GL840
  • Communication method: Wireless communication (using radio waves in the 2.4GHz band)
  • Supported WLAN systems: IEEE802.11b/g/n
  • WPS: Push button or PIN method
  • Security protocols: WEP64, WEP128, WPA-PSK/WPA2-PSK, AKIP/AES
  • Communication distance: Approx. 40m (depending on the conditions of radio communication)
  • Installed location: Attached to the SD CARD slot number 2 on the GL840
  • * When the wireless LAN unit is installed, the SD memory card cannot be used in slot number 2
  • Function Access Point mode: Communicate with the GL100-WL as a remote sensor (captured data in the GL100-WL is transferred to GL840)
  • Station mode: Communicate with PC or Smart device (control GL840 and transfer the data from GL840)
  • Connected number of GL100-WL: GL840: Up to 5 units of the GL100-WL
  • GL840 Analog input specifications:
  • Model number: GL840-M, Input terminal B-564
  • Input method: All channels isolated balanced input *11, Scans channels for sampling
  • Type of input terminal: Screw terminal (M3 screw)
  • Measurement range: Voltage 20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50, 100 V, and 1-5V F.S. (Full Scale)
  • Thermocouple: Type: K, J, E, T, R, S, B, N, W (WRe5-26)
  • Ranges: 100, 500, 2000 ºC *12
  • RTD (Resistance Temperature Detector): Type: Pt100, JPt100 (JIS), Pt1000 (IEC751)
  • Ranges: 100, 500, 2000 ºC *12
  • Humidity: 0 to 100 % RH - using the humidity sensor (option B-530)
  • Filters: Off, 2, 5, 10, 20, 40 (moving average in selected number)
  • Measurement accuracy *13: Voltage ± 0.1% of F.S. (Full Scale)
  • NOTE: For complete specifications. See Brochure/Datasheet

  • (1) AC Adapter
  • (1) Software on CD
  • Note: 
  • Battery Pack is not included (order separately)
  • Calibration Certificate not included. Order separately

Download