HD2817T… Transmitter, indicator, ON/OFF regulator, temperature and humidity datalogger.
The HD2817T... series instruments are transmitters, indicators, ON/OFF regulators with datalogger function. They measure temperature and humidity. They are fitted with an LCD backlit graphic display 128x64 pixel. The main characteristic of these instruments is the interchangeable probe. The user can virtually change the probe without interrupting the process. Then the probe can be calibrated or repaired.

We have models with horizontal (S.TO), vertical (S.TV) or separate (S.TC) probes, connected to the instrument using cables of different lengths. The S.TO and S.TV probes are made of AISI304 steel, the S.TC probes can be made of AISI304 steel or POCAN plastic material. To measure the dew point in compressed air systems, the probe S.TC2.480.2 can be connected to the HD2817T...
The probe, factory calibrated and ready for use, is fitted with a SICRAM2 module storing its calibration information and allowing its interchangeability.

The devices measure:
  • Temperature in Celsius or Fahrenheit degrees
  • Relative humidity
and calculate:
  • Absolute humidity
  • Mixing ratio
  • Dew point
  • Wet bulb temperature
All models are fitted with current or voltage analogue outputs. We supply models with two working relays and an alarm relay, user configurable. All models have a multistandard RS232/RS485 output and an auxiliary RS232C serial output. You can connect several network devices through the RS485 serial port. The HD2817T... models use a wide LCD backlit graphic display (128x64 pixel) showing three physical quantities simultaneously or a real time graph of any of the measured quantities.

The datalogger function allows recording of the measurements detected by the instrument, according to a frequency set by the user. The instrument configuration is permanently stored. The internal clock is protected against a mains power failure by a special Lithium battery. When making the order, you can select the power supply between 24Vac/dc or universal 90...240Vac.

Probes:

  • S.TV – Vertical probe L= 130mm, AISI 304

The material of the S.TC…probes can be chosen between stainless steel AISI304 or plastic material. (recognized by the letter P in the code)

  • S.TC1.2 and S.TC1.2P – Probe L=135mm with cable 2m
  • S.TC1.5 and S.TC1.5P – Probe L=135mm with cable 5m
  • S.TC1.10 and S.TC1.10P – Probe L=135mm with cable 10m
  • S.TC2.2 and S.TC2.2P – Probe L=335mm with cable 2m
  • S.TC2.5 and S.TC2.5P – Probe L=335mm with cable 5m
  • S.TC2.10 and S.TC2.10P – Probe L=335mm with cable 10m

Probes with cable for measurements in pipelines: S.TC2.480.2 and S.481.2

  • S.TO1 – horizontal probe L= 135mm
  • S.TO2 – horizontal probe L= 335mm

There are no reviews for this product.

Write a review

  • Temperature:
  • Sensor Pt100 Class 1/3 DIN
  • Sensor working range -50 ... +200°C (-58 ...+392°F)
  • Humidity:
  • Relative humidity %RH 0 ... 100%RH
  • Temperature sensor working range -50 ... +150°C (Special configurations on request up to 180°C)
  • Dew Point TD -50 ... +100°C
  • Absolute humidity 0 ... 600g/m3
  • Mixing ratio 0 ... 2000g/kg of dry air
  • Wet bulb temperature -50 … +100°C
  • Outputs:
  • Communications Type RS232C and Multidrop RS485; Baud rate 9600 baud; 57600 baud not permanent
  • Physical quantities Measured Temperature, relative humidity; Calculated Absolute humidity, mixing ratio, dew; point, wet bulb temperature
  • Analog outputs:
  • Number 3
  • Type of outputs 4...20mA; 0...20mA;0...10Vdc; 2…10Vdc
  • Load resistance Current output: 500 max
  • Voltage output: 100k min
  • Resolution 16bit
  • Accuracy of analog outputs 0.05% f.s. @20°C In case of measurement error (out of functioning limits, faulty or disconnected probe,...) Idc = 22mA Vdc = 11V

  • Technical information (@ 24Vdc and 20°C):
  • Inputs:
  • Temperature Sensor: Pt100 Class 1/3 DIN
  • Sensor working range; -50 ... +200°C (-58 ...+392°F)
  • Humidity:
  • Relative humidity: %RH 0 ... 100%RH
  • Temperature sensor working range: -50 ... +150°C (Special configurations on request up to 180°C)
  • Dew Point:TD -50 ... +100°C
  • Absolute humidity: 0 ... 600g/m3
  • Mixing ratio: 0 ... 2000g/kg of dry air
  • Wet bulb temperature:  -50 … +100°C
  • Accuracy of the measured physical quantities: Pt100 Temperature: 0.25°C;
  • Relative humidity %RH: 1.5 %RH (0...90 %RH), 2.0 %RH for the remaining range for T=15…35 °C;  ± (1.5 + 1,5% of the measured value) %RH for the remaining temperature range
  • Accuracy of the calculated physical quantities:  Please see also the tables on the next paragraph: Accuracy of the Dew Point @T=20°C; ± 2°C DP (-40..-20°C DP); ±1,5°C DP (-20..0°C DP); ±1°C DP (0…20°C DP)
  • Response time: 3min with strainer (at 20°C and 0.5m/s)
  • Outputs:
  • Communications: Type RS232C and Multidrop RS485, Baud rate: 9600 baud, 57600 baud not permanent
  • Physical: quantities Measured Temperature, relative humidity; Calculated Absolute humidity, mixing ratio, dew point, wet bulb temperature
  • Analog outputs Number: 3
  • Type of outputs: 4...20mA; 0...20mA; 0...10Vdc; 2…10Vdc
  • Load resistance: Current output: 500 max; Voltage output: 100k min
  • Resolution: 16bit
  • Accuracy of analog outputs: 0.05% f.s. @20°C
  • In case of measurement error (out of functioning limits, faulty or disconnected probe,...): Idc = 22mA; Vdc = 11V
  • Relay: Working relay:  2 x 3A/250Vac resistive load, 1 exchange contact; Alarm relay: 1 x 3A/250Vac resistive load,1 normally open contact
  • Instrument:
  • Power Versions: 24Vdc / 24Vac 50…60Hz, 10%; 90 ... 240Vac 50…60Hz; Average consumption: 3W
  • Datalogger: Storage capacity: 9000 samples in 256 sessions max; Type of memory: Circular memory
  • Logged parameters: Temperature, relative humidity, absolute humidity, mixing ration, dew point, wet bulb temperature analog outputs 1, 2 and 3, status of relays 1, 2, 3
  • Logging interval: 1, 2, 5, 10, 20, 60 seconds, 2 and 4 minutes
  • Internal clock: Type In real time with lithium backup battery
  • Accuracy: 1min/month
  • Software: DeltaLog12 for Windows® from 98
  • Display: Graphic, backlit 128x64 pixel
  • Electronics environment conditions: Functioning temperature -20…+60°C; Relative humidity 0…90%RH - without condensation; Sensor working static pressure 12 bar max; Storage temperature: -30…+80°C
  • Case: W x H x D: 143x154x61; Weight: 600g; Material: ABS; Protection degree Electronic IP65