• Ametek RTC-156 Reference Temperature Calibrator, -30° to 155°C (-22° to 311°F), Full Model

Ametek RTC-156 Reference Temperature Calibrator, -30° to 155°C (-22° to 311°F), Full Model

Not yet rated Write a review
Ametek

Available Options

Rp.438,832,800
Availability:
4 - 6 WEEKS
Product Code:
RTC156B
Brand:
Ametek
Update Terakhir:
16 May 2024
  • Free delivery

  • Money back guarantee

Share

Ametek RTC-156 Reference Temperature Calibrator, -30° to 155°C (-22° to 311°F), Full Model. The Ametek RTC-156 and RTC-157 reference temperature calibrators combine Ametek's unparalleled experience with temperature calibration with cutting edge technological features creating the most sophisticated dry block temperature calibrators on the market. The Ametek RTC-156 has a temperature range of -30° to 155°C, while the RTC-157 has a temperature range of -45° to 155°C. Both units boast outstanding accuracy and stability while featuring Ametek's Dynamic Load Compensation (DLC) system that provides perfect temperature uniformity in the insert no matter the number or size of the sensors immersed. The calibrators also offer unique intelligent sensors for plug ‘n' play connectivity, an easy-to-read full-color 5.7-inch VGA display, and a USB connection for improved communications and software downloads. The Ametek RTC-156 and RTC-157 reference temperature calibrators are available in three configurations: RTC-A reference temperature calibrator, RTC-B reference temperature calibrator with input for reference sensor, DLC sensor and sensors-under-test, and RTC-C reference temperature calibrator with input for reference sensor and DLC sensor. The RTC-156 and RTC-157 can be used without an external reference sensor. However, users will obtain better accuracies and realize the calibrator's full potential by utilizing the STS-200 reference sensor. Both the STS-200 and DLC sensors contain all individual calibration data regarding the sensor, allowing users to change the reference sensor and be up and running immediately. The RTC-156 and RTC-157 feature a rugged, lightweight design and multi-hole inserts that cover most commonly used sensor sizes.


  • Full model: includes DLC sensor; reference sensor & sensor under test input
  • Accurate to ±0.04°C using the external reference sensor
  • 4-wire True-Ohm-Measurement technology
  • Excellent stability: 0.005°C
  • Wide temperature range
  • RTC-156: -30 to 155°C (-22 to 311°F)
  • RTC-157: -45 to 155°C (-49 to 311°F)
  • Unique active dual-zone block for improved temperature homogeneity
  • Dynamic Load Compensation for perfect temperature uniformity in the insert
  • Display indicator for temperature uniformity
  • Intelligent reference sensors hold the calibration data (coefficients) of the reference sensor
  • USB communication
  • High speed heating and cooling times
  • Best performing dry-block with regard to the EURAMET/cg-13/v.01 guideline for testing of dry-blocks

  • Temperature range:
  • RTC-156
  • @ ambient temp. 0°C/32°F: -46 to 155°C/-51 to 311°F
  • @ ambient temp. 23°C/73°F: -30 to 155°C/-22 to 311°F
  • @ ambient temp. 40°C/104°F: -15 to 155°C/ 5 to 311°F
  • RTC-157
  • @ ambient temp. 0°C/32°F: -57 to 155°C/-71 to 311°F
  • @ ambient temp. 23°C/73°F: -45 to 155°C/-49 to 311°F
  • @ ambient temp. 40°C/104°F: -31 to 155°C/-24 to 311°F
  • Accuracy (model B & C) with external STS ref. sensor:
  • RTC-156 B & C:  ±0.04°C/±0.07°F
  • RTC-157 B & C:  ±0.04°C/±0.07°F
  • 12-month period. Relative to reference standard. Specifications by use of the external JOFRA STS-200 reference sensor
  • Accuracy with internal reference sensor:
  • RTC-156 A, B & C:  ±0.10°C/±0.18°F
  • RTC-157 A, B & C: ±0.10°C/±0.18°F
  • Stability:
  • RTC-156: ±0.005°C/±0.009°F1)
  • RTC-157: ±0.005°C/±0.009°F1)
  • Measured after the stability indicator has been on for 15 minutes. Measuring time is 30 minutes.
  • Radial homogeneity (difference between holes):
  • RTC-156: 0.01°C/0.02°F
  • RTC-157: 0.01°C/0.02°F
  • Resolution (user-selectable):
  • All temperatures : 1° or 0.1° or 0.01° or 0.001˚
  • Heating time:
  • RTC-156 
  • -30 to 23°C/-22 to 73°F: 4 minutes
  • 23 to 155°C/73 to 311°F: 15 minutes
  • RTC-157 
  • -45 to 23°C/-49 to 73°F: 7 minutes
  • 23 to 155°C/73 to 311°F: 8 minutes
  • Cooling time:
  • RTC-156
  • 155 to 100°C/311 to 212°F:  4 minutes
  • 100 to 23°C/212 to 73°F.:  8 minutes
  • 23 to -24°C/73 to -11°F:  15 minutes
  • -24 to -30°C/-11 to -22°F: 10 minutes
  • RTC-157   155 to 100°C/311 to 212°F:  5 minutes
  • 100 to 23°C/212 to 73°F:  10 minutes
  •  23 to -30°C/73 to -22°F:  17 minutes
  •  -30 to -45°C/-22 to -49°F: 25 minutes
  • Time to stability (approx.):
  • RTC-156: 10 minutes
  • RTC-157:  10 minutes
  • Immersion depth:
  • RTC-156: 160 mm/6.3 in
  • RTC-157:  160 mm/6.3 in
  • Thermocouple input:
  • Range : ±78 mV
  • F.S. (Full Scale) : 78 mV
  • Accuracy (12 months) :  ±(0.005% Rdg. + 0.005% F.S.)
  • Transmitter supply:
  • Output voltage:  24VDC ±10%
  • Output current: Maximum 28 mA
  • Transmitter input mA (B model only)
  • Range : 0 to 24 mA
  • Accuracy (12 months) : ±(0.005% Rdg. +0.010% F.S.)
  • Voltage input VDC (B model only)
  • Range: :  0 to 12 VDC
  • Accuracy (12 months): ±(0.005% Rdg. +0.010% F.S.)
  • Switch input (B model only):
  • Switch dry contacts
  • Test voltage.: Maximum 5 VDC
  • Test current : Maximum 2.5 mA
  • Mains specifications:
  • Voltage: 115V (90-127) / 230V (180-254)
  • Frequency, non US deliveries : 50 Hz ±5, 60 Hz ±5
  • Frequency, US deliveries: 60 Hz ±5
  • Power consumption (max.) : 400 W
  • RTD reference input (B & C models only)
  • Type.:  4-wire RTD with true ohm measurements1)
  • F.S. (Full Scale) : 400 ohm
  • Accuracy (12 months) :  ±(0.0012% rdg. + 0.0005% F.S.)
  • RTD sensor under test input (B model only)
  • F.S. (range) : 400 ohm
  • Accuracy (12 months):  ±(0.002% Rdg.+0.002% F.S.)
  • F.S. (range): 4000 ohm
  • Accuracy (12 months) :  ±(0.005% Rdg. + 0.005% F.S.)
  • 2-wire: add 50 mOhm
  • Communication interface:
  • Serial data interface : .USB 2.0 device port
  • Serial data interface : USB 2.0 host double port*
  • LAN: . Ethernet MAC 10/100 Base-T*
  • SD:  SD slot*
  • * for future expansion
  • Miscellaneous:
  • Operating temperature: 0 to 40°C/32 to 104°F
  • Storage temperature: -20 to 50˚C/-4 to 122˚F
  • Humidity :  0 to 90% RH
  • Protection class : IP-10
  • PHYSICAL SPECIFICATIONS
  • Weight and instrument size (L x W x H):
  • RTC-156/157:10.5 kg/23.2 lb
  • RTC-156/157: 362 x 171 x 363 mm/14.3 x 6.7 x 14.3 in
  • Shipping (without carrying case):
  • RTC-156/157: 14.8 kg/32.6 lb
  • Size: 570 x 235 x 440 mm/22.4 x 9.3 x 17.3 in
  • Shipping (including optional carrying case):
  • RTC-156/157: 20.5 kg/45.1 lb
  • Size: 650 x 380 x 500 mm/25.5 x 14.9 x 19.7 in
  • Shipping (carrying case only):
  • Weight: 8.0 kg/13.2 lb
  • Size: 650 x 380 x 500 mm/25.5 x 14.9 x 19.7 in
  • INSERTS:
  • Insert dimensions:
  • RTC-156/157 outer diameter : 29.7 mm/1.17 in
  • RTC-156/157 inner diameter (multi hole):  25.6 mm/1.01 in
  • RTC-156/157 inner diameter (single hole): 22.0 mm/0.87 in
  • RTC-156/157 length.: 150 mm/5.91 in
  • Weight of non-drilled insert (approx.):
  • RTC-156/157: 290 g/10.2 oz
  • Use of other inserts may reduce performance of the calibrator. To get the best results out of the calibrator, the insert dimensions, tolerance and material is critical. We
  • highly advise using JOFRA inserts, as they guarantee trouble free operation.

  • (1) RTC-156 dry-block calibrator w/DLC sensor; reference sensor & sensor under test input
  • (1) Mains power cable
  • (1) Test cables (2 x red, 2 x black)
  • (1) Traceable certificate - input performance for reference sensor and DLC sensor
  • (1) Traceable certificate - input performance for sensorunder-test inputs
  • (1) Tool for insertion tubes
  • (1) JOFRACAL
  • (1) USB cable
  • (1) Set of rubber cones for insulation plugs
  • (1) Manual

                  Download

                  Note: Prices are not binding at any time subject to change without prior notice