  • Ametek CTC-652 [CTC-652-A-230A-007-XX-F-XX] Temperature Calibrator, 28 to 650°C (82 to 1202°F) w/7mm Metric Insert Size, 230V EU, Basic Model

Ametek CTC-652 [CTC-652-A-230A-007-XX-F-XX] Temperature Calibrator, 28 to 650°C (82 to 1202°F) w/7mm Metric Insert Size, 230V EU, Basic Model

Not yet rated Write a review
Ametek
Rp.233.495.200
Availability:
4 - 6 WEEKS
Product Code:
CTC-652-A-230A-007-XX-F-XX
Brand:
Ametek
Update Terakhir:
02 Aug 2024
  • Free delivery

  • Money back guarantee

Share

Ametek CTC-652 [CTC-652-A-230A-00-XX-F-XX] Temperature Calibrator, 28 to 650°C (82 to 1202°F) w/7mm Metric Insert  Size, 230V EU, Basic Model.
Ametek CTC-652 Temperature Calibrator, 28 to 650°C (82 to 1202°F). The Ametek CTC Series is a fast, time-saving, reliable dry block temperature calibrator designed for on-site use. Available in three models with ranges from -25 to 155°C (-13 to 311°F), 28 to 350°C (82 to 662°F), and 28 to 660°C (82 to 1220°F); the CTC series offers the speed, portability, cleanliness, and wide temperature range which are all superior to liquid bath systems. The CTC series provides exceptional accuracy and stability. The large color display is easy-to-read and provides icons and information regarding the status of the calibrator and the calibration in process. Popular functions like automatic switch test and auto stepping are available with special one-key-one-function buttons. When switching on the calibrator or connecting the reference sensor, the calibrator immediately warns you if any of the calibration certificates are overdue. A buzzer and warning appears. The recalibration interval can be set from 1 to 99 months. The CTC series is available with an optional signal input for an external reference sensor. The sensor makes it possible to improve accuracy even more. The CTC can be run in two modes when using the external reference sensor. "External ref" mode is where the external reference sensor represents the True value. The "Set follows True" mode is where the reference sensor serves two purposes; measuring the reference temperature and at the same time controlling the block temperature to the set temperature. The Ametek CTC is supplied with our highly versatile calibration software JofraCal. All calibrations can be documented with a certificate, given that the CTC is controlled from a PC. When the calibrator has reached the desired temperature and stabillity it will prompt you to type in the UUT temperature. JofraCal documents all your calibration needs within temperature, pressure and process calibration.


  • Part Number: CTC-652-A-230A-007-XX-F-XX
  • Temperature Range: 28 to 650°C (82 to 1202°F)
  • Model: Basic model, without input
  • Power Supply: 230 VAC
  • Insert Type: Metric sizes
  • Insert Size: 7mm
  • External Reference Sensor: Without
  • Calibration Certificate: Traceable to International Standards
  • Accessories: Without
  • Temperature range from 28 to 650°C (82 to 1202°F) with 5 models
  • Accuracy to ± 0.65°C and Stability to ± 0.05°C
  • Calibrate Long Sensors with the CTC-652s 190 mm immersion depth
  • Lightweight and easy to carry
  • Multi-hole and/or insert kits
  • Input for external reference sensor on all C models
  • MVI circuitry ensures stability despite mains supply variations
  • Rugged, portable temperature calibrator

  • Temperature:
  • Temperature Range:
  • @ Ambient 23°C/73°F: 28 to 650°C / 82 to 1202°F
  • @ Ambient 0°C/32°F: 5 to 650°C / 41 to 1202°F
  • Accuracy *
  • CTC-652 With Internal Reference Sensor: 
  • @ 650°C / 1202°F:  ±0.65°C /±1.17°F
  • @ 400°C / 752°F :  ±0.60°C /±1.08°F
  • @ 200°C / 392°F :  ±0.50°C /±0.90°F
  • CTC-652 With External Reference Sensor STS-200-A-970: 
  • @ 650°C / 1202°F : ±0.45°C /±0.81°F
  • @ 400°C / 752°F: ±0.40°C /±0.72°F
  • @ 200°C / 392°F: ±0.35°C /±0.63°F
  • Stability:
  • CTC-652 **: ±0.05°C / ±0.09°F
  • Radial Homogeneity (difference between holes)
  • CTC-652 @ 650°C / 1202°F: 0.08°C / 0.14°F
  • CTC-652 @ 400°C / 752°F:  0.03°C / 0.054°F
  • Influence From Load Ø6mm 28 to 650°C / 82 to 1202°F
  • With Internal Reference: 0,1°C / 0.18°F
  • With External Reference:  0,03°C / 0.054°F
  • Settings:
  • Resolution: 1 or 0.1 or 0.01
  • Units: °C or °F or K
  • Heating Time:
  • CTC-652: 23 to 650°C / 73 to 1202°F. . . 33 minutes
  • Cooling Time:
  • CTC-652: 650 to 100°C / 1202 to 212°F. . . 48 minutes
  • CTC-652: 100 to 50°C / 212 to 122°F. . . 25 minutes
  • Time to Stability (typical)
  • CTC-652 : 5 minutes
  • Mains Power:
  • Voltage ****.: 115 V (103-127) / 206 V (180-254)
  • Max Power Consumption: 1150 VA
  • Frequency, US deliveries: 60 Hz ±3
  • Frequency, non US deliveries: 50 Hz ±3, 60 Hz ±3
  • Physical Specifications:
  • Dimension L x W x H: 248x148x390 mm / 9.76x5.83x15.35 in
  • Weight:
  • CTC-652: 9.0 kg / 19.8 lb
  • Immersion Depth:
  • CTC-652: 190 mm / 7.48 in
  • Well Diameter:
  • CTC-652: 26 mm / 1.02 in
  • Insert Dimensions (diameter x length)
  • CTC-652:  25.7 mm x 200 mm / 1.01 x 7.874 in
  • Electrical:
  • Switch Input (dry contact)
  • Test Voltage: Maximum 14 VDC
  • Test Current: Maximum 1 mA
  • Digital Interface: USB 2.0
  • Environmental:
  • Operating Temperature:
  • 0 to 50°C / 32 to 122°F
  • Storage Temperature: -20 to 50°C / -4 to 122°F
  • Humidity: 5 to 90% Rh, non-condensing
  • Protection Class: IP-10
  • External Reference Sensor:
  • STS-200-A-970: 0 to 700°C / 32 to 1292°F
  • Accuracy:
  • Hysteresis (@ 0°C / 32°F): 0.01°C / 0.018°F
  • Long Term Stability (@ 0°C / 32°F) ***: 0.016°C / 0.029°F
  • Repeatability: 0.002°C/ 0.0036°F
  • Sensing element:
  • Type:  Pt100
  • Response Time:
  • STS-200-A-970: t0.5 (50%) : 8 sec.
  • STS-200-A-970: t0.9 (90%) : 26 sec.
  • Dimensions:
  • Diamete: 4 mm / 0.157 in
  • Length:  241 mm / 9.29 in
  • Max. height over calibrator top: 35 mm / 1.38 in
  • Please note: All specifications are given with an ambient temperature 23°C / 73.4°F ± 3°C / 5.9°F and specified at 115 V/230 V.
  • *) In lower 40 mm incl. Stability, Uniformity, 12-month drift (typical), Hysteresis, Resolution, Load (Max 6 mm) and calibration laboratory uncertainty.
  • **) Measured after the stability indicator has been on for 10 minutes. Measuring time is 30 minutes.
  • ***) Stability when exposed to maximum temperature for 100 hours. Stability will depend on actual use of the probe.
  • ****) 103V-127VAC/206-254VAC 47-63 Hz for full temperature range. At mains voltage below 103VAC/206VAC maximum temperature will be reduced.

  • (1) CTC652 dry-block calibrator
  • (1) 7mm Metric Insert  Size
  • (1) Mains power cable 230V EU
  • (1)Traceable certificate - temperature performance
  • (1) Tool for insertion tubes
  • (1) User manual
  • (1) Test cables (1 x red, 1 x black)
  • (1) USB cable
  • (1) JofraCal calibration software
  • (1) CTC-660 and CTC-652 includes a Heat Shield

Download

Note: Prices are not binding at any time subject to change without prior notice


  Options 0 Item Selected
Image
Model
Product Name
Price
Available
Quantity
Ametek CTC-652 [CTC-652-A-230A-007-XX-F-XX] Temperature Calibrator, 28 to 650°C (82 to 1202°F) w/7mm Metric Insert Size, 230V EU, Basic Model
CTC-652-A-230A-007-XX-F-XX
Rp.233.495.200
4 - 6 WEEKS
Ametek CTC-652 [CTC-652-A-230A-007-XX-F-SR] Temperature Calibrator, 28 to 650°C (82 to 1202°F) w/7mm Metric Insert Size, 230V EU, Basic Model, Support Rod Set
CTC-652-A-230A-007-XX-F-SR
Rp.244.247.200
4 - 6 WEEKS
Ametek CTC-652 [CTC-652-A-230A-007-XX-F-CX] Temperature Calibrator, 28 to 650°C (82 to 1202°F) w/7mm Metric Insert Size, 230V EU, Basic Model, Solid Protective Carrying Case
CTC-652-A-230A-007-XX-F-CX
Rp.251.927.200
4 - 6 WEEKS
Ametek CTC-652 [CTC-652-A-230A-007-XX-F-CR] Temperature Calibrator, 28 to 650°C (82 to 1202°F) w/7mm Metric Insert Size, 230V EU, Basic Model, Solid Protective Carrying Case & Support Rod Set
CTC-652-A-230A-007-XX-F-CR
Rp.262.039.200
4 - 6 WEEKS
  Accessories 0 Item Selected