The AEMC PowerPad III 8333 [2136.11] is a three-phase power quality analyzer that is easy-to-use, compact and shock resistant.The AEMC 8333 enables technicians and engineers to measure and carry out diagnostics and power quality work on single or three-phase networks. Three current and four voltage input terminals are provided are provided. Additionally, the AEMC PowerPad III 8333 is IEC 61000-4-30 Class B and safety rated to 600V CAT IV.
An easy to use three-phase power quality analyzer with four voltage and three current input terminals. Featuring 2 GB of memory for trend recordings, as well as up to 12 snapshots, 51 captured transients and 4000 alarm events. This basic unit does not include probes The AEMC 8333 has memory available for storing trend data, alarms, transients, and snapshot data. The user can store on the AEMC PowerPad III 8333 up to 12 screen snapshots, up to 51 captured transients that contain four cycles for each active input, and 4,000 alarm events from up to 10 different parameters. Trend data can also be recorded for days, weeks or even months.
Measurement of TRMS voltages up to 1000Vrms AC / 1200VDC for single or three phase networks
Measurement of TRMS currents up to 10kArms (sensor dependent)
Calculation of neutral current and voltage
Frequency measurement (40 to 70Hz systems)
Records and displays trend data as fast as once per second for one month up to 29 variables
Captures up to 51 transient occurrences on all V and A inputs
Measures harmonics (referenced to the fundamental or RMS value) for voltage, current or power up to the 50th harmonic
Recording, time stamping and characterization of disturbances (swells, sages and interruptions, exceedence of power and harmonic thresholds)
Measures energy VAh, VARh & Wh and reports quantities according to IEEE 1459 standards (P; Q1; D; N; S)
65μs/sample transient recording
DataView software is included for configuring real-time display and report generation
Applications:
Verification of power distribution circuits
In-plant troubleshooting of power distribution panels and individual machinery
Monitor pad mount transformers and phase unbalances
Determine harmonic problems originating from source or load
Determine transformer K-Factor
Energy metering (kVAh, VARh, kWh)
Channels: 3 voltage / 4 current
Inputs: 4 voltage / 3 current
Voltage(TRMS AC+DC): 2 to 1000V
Voltage Ratio: up to 500kV
Current(TRMS AC+DC): MN93: 500mA to 200Aac; MN193: 0.005to 100aac, SR193 clamp:1a to 1000a ac AmpFlex® ,MA193 Clamps: 100mA to 10000Aac, MR193 clamp: 1a to 1300a ac/dc, SL261 clamp: 50ma to 100a ac/dc, Current Ratio: up to 60ka