Aalborg DPM series digital multi-parameter mass flow meters provide accurate measurements of mass and volumetric flow rates, pressures and temperatures of process gases. DPM mass flow meters incorporate multi-parameter multi-gas functionality which allows users on site to select up to 30 different gases locally via optional OLED/Joystick interface, or remotely via the RS232/RS485 interface, or optional Modbus RTU interface.

DPM flow meters support two programmable flow totalizers, low, high or range flow, temperature and pressure alarms, automatic zero adjustment (activated via local or communication interface), programmable SSR relay, programmable 0-5 Vdc, 0-10 Vdc or 4-20 mA analog outputs, user-programmable pulse output (via SSR), and extensive self-diagnostics. DPM mass flow meters feature multi-parameter/multi-gas functionality, ± (0.5% RD + 0.2%FS) standard accuracy, 200:1 turndown ratio and 10-20 ms response time.

Used in a variety of industries: scientific and analytical applications, bioreactors and surface depositions, gas sampling, manufacturing and metrology activities. Significant savings are apparent, comparing the cost of a single DPM meter embodying these features, with that of acquiring and installing multiple, application-specific devices.

  • Multi-Parameter functionality: Mass Flow, Volumetric Flow, Gas Pressure and Temperature.
  • Multi-Gas functionality: support for 90 different gases and gas mixes.
  • “User Defi ned Mixture” functionality allows to create and store up 20 custom gas mixes with up to 5 different gases each.
  • Quick (< 20ms) response time.
  • Standard accuracy ± (0.5% RD + 0.2% FS).
  • 200 to 1 turndown ratio.
  • Two programmable mass fl ow rate totalizers.
  • High, Low or In Range Alarms with preset action delay for Mass Flow, Temperature and Pressure.
  • User programmable mass fl ow rate Pulse Output (via SSR).
  • Extensive Self Diagnostics with status LED or OLED indication.
  • All 3 user selectable analog output interfaces are standard: 0-5Vdc, 0-10Vdc, 4-20mA.
  • Two user selectable digital communication interfaces (RS-232 and RS-485) are standard.
  • Optional Modbus RTU network interface with isolated RS485 transceiver.
  • User programmable solid state relay with latch option.
  • Universal 9-26 Vdc power supply input.
  • Local high contrast OLED (optional) graphic display with joystick control.
  • Free, easy-to-use confi guration and calibration software (RS-232/RS-485).

FLOW MEDIUM: Please note that DPM Mass Flow Meters are designed to work only with
clean, non-corrosive gases. Never try to measure fl ow rates of liquids with any DPM.
CALIBRATIONS:  Perform at standard conditions [14.7 psia (101.4 kPa) and 70 °F (21.1 °C)] unless otherwise requested or stated.
ENVIRONMENTAL (PER IEC 664): Installation Level II; Pollution Degree II.
FLOW ACCURACY (INCLUDING LINEARITY): ±(0.5% RD + 0.2% FS) at calibration temperature and pressure.
REPEATABILITY: ±0.15% of full scale.
FLOW TEMPERATURE COEFFICIENT: 0.05% of full scale/ °C or better.
FLOW PRESSURE COEFFICIENT: 0.01% of full scale/psi (6.895 kPa) or better.
FLOW RESPONSE TIME: Default 10 ms (adjustable by user).
INSTRUMENT WARM-UP TIME: < 5 seconds.
MAXIMUM MEASURABLE FLOW RANGE: 133% Full Scale.
OPERATING RANGE / TURNDOWN RATIO: 0.5% to 100% Full Scale / 200:1.
MASS REFERENCE CONDITIONS (STP): 70 °F & 14.696 PSIA (other available on request).
MAXIMUM INTERNAL GAS PRESSURE (STATIC):
DPM07 /17 /37 /47 /57 /67 /77 120 PSIG
DPM04 /14 /24 /34 /44 /54 50 PSIG
MAXIMUM INSTANTANEOUS DIFFERENTIAL PRESSURE ACROSS INLET AND OUTLET:
DPM07 /17 /37 /47 /57 /67 /77 12 PSID
DPM04 /14 /24 /34 /44 /54 9.75 PSID
PROOF PRESSURE:
DPM07 /17 /37 /47 /57 /67 /77 145 PSIG
DPM04 /14 /24 /34 /44 /54 50 PSIG
OPERATING TEMPERATURE: -10 to +60 °C (14 to 140 °F).
MOUNTING ATTITUDE SENSITIVITY: None.
RELATIVE GAS HUMIDITY RANGE: 0 to 100% (Non -Condensing).
INGRESS PROTECTION: IP40.
OUTPUT SIGNALS: Linear 0-5 Vdc (3000 ohms min. load impedance);
Linear 0-10 Vdc (5000 ohms min. load impedance); with power supply >= 12Vdc.
Linear 4-20 mA (550 ohms maximum loop resistance) with power supply >= 12Vdc.
Maximum noise 10mV peak to peak (for 0-5/0-10 Vdc output).
TRANSDUCER INPUT POWER:  9 to 26 Vdc, 150 mV maximum peak to peak output noise. Power consumption: 100 mA
maximum. Circuit board has built-in polarity reversal protection, 300mA resettable fuse
provide power input protection.
DIGITAL OUTPUT SIGNALS: Standard RS-232 or RS-485 (user selectable).
Optional Modbus over isolated RS-485 transceiver.
**MATERIALS FLUID CONTACT: 316 stainless steel, 416 stainless steel, high temperature polyamide, alumina ceramic,
epoxy, silicone, glass, gold. Viton® O-rings. 

  • (1) Instruction Manual

Download

Note: Prices are not binding at any time subject to change without prior notice


  DPM MODEL 0 Item Selected
Image
Model
Product Name
Price
Available
Quantity
DPM Mass Flow Meter
Rp.33.600.000
1 Availability
  DPM MAX FLOW (Air) 0 Item Selected
  DPM MATERIAL 0 Item Selected
  DPM SEALS 0 Item Selected
  DPM CONNECTIONS 0 Item Selected
  DPM READOUT 0 Item Selected
  DPM POWER 0 Item Selected
  DPM OUTPUT SIGNAL 0 Item Selected
  DPM DIGITAL INTERFACE (Modbus) 0 Item Selected
  DPM FLOW RANGE 0 Item Selected
  DPM GAS 0 Item Selected