Delta Ohm HD2108 Data Logger Thermocouple Thermometer

Not yet rated Write a review
Delta Ohm

Available Options

Rp.9.018.400
Availability:
2 - 4 WEEKS
Product Code:
HD2108
Brand:
Delta Ohm
Update Terakhir:
19 Aug 2023
  • Free delivery

  • Money back guarantee

Share

The HD2108.1 and HD2108.2 with one input and the HD2128.1 and HD2128.2 with two inputs are portable instruments with a large LCD display. They measure the temperature using immersion, penetration, air or contact probes. The sensor may be a thermocouple of type K, J, T, N, R, S, B or E. Instruments HD2108.2 and HD2128.2 are data loggers, they store up to 76.000 samples the first and 38.000 couples of values the second. These data can be transferred into a PC connected to the instrument through the serial ports RS232C and USB 2.0. It is possible to configure the storage interval, the printing and the baud rate by the menu. Functions Max, Min and Avg calculate maximum, minimum and average values. Further functions are: REL relative measure, HOLD and automatic switchingoff system (excludable). HD2128.1 and HD2128.2 calculate A-B difference of the temperatures acquired by the two input channels.

Instruments have IP66 protection degree.

  • Unit of measurement ° C - ° F - ° K - mV -mV * C
  • Type K, J, T, N, R, S, E thermocouple
  • With datalogger function
  • Autonomy of 200 hours with 1800 mAh alkaline batteries
  • Power supply 4 1.5V AA batteries
  • Degree of protection IP66

  • Measurement of temperature by instrument:
  • TC measuring range: K -200…+1370°C
  • TC measuring range: J -100…+750°C
  • TC measuring range: T -200…+400°C
  • TC measuring range: N -200…+1300°C
  • TC measuring range: R +200…+1480°C
  • TC measuring range: S +200…+1480°C
  • TC measuring range: B +200…+1800°C
  • TC measuring range: E -200…+750°C
  • Resolution: 0.05°C in the range ±199.95°C0.1°C in the remaing range
  • Instrument accuracy: Accuracy is referred to the instrument only; error due to the thermocoupleor to the cold junction reference sensor is not included.
  • Thermocouple K: ±0.1°C up to 600°C; ±0.2°C over 600°C
  • Thermocouple J:  ±0.05°C up to 400°C; ±0.1°C over 400°C
  • Thermocouple T: ±0.1°C; Thermocouple N ±0.1°C up to 600°C; ±0.2°C over 600°C
  • Thermocouple R:  ±0.25°C
  • Thermocouple S: ±0.3°C
  • Thermocouple B:  ±0.35°C
  • Thermocouple E: ±0.1°C up to 300°C; ±0.15°C over 300°C
  • Temperature drift @20°C: 0.02%/°C
  • Drift after 1 year: 0.1°C/year
  • Unit of measurement: °C - °F - K - mV - mV*C
  • Measured values storage:
  • Model HD2108.2: 2000 pages each one containing 38 samples, 76000 samples in total
  • Model HD2128.2: 2000 pages each one containing 19 samples, 38000 samples in total
  • Storage interval can be selected among: 1,5,10,15,30 s; 1,2,5,10,15,20,30 min.; 1 hour
  • Security of stored data; Unlimited, independent of battery charge conditions
  • Power Supply:
  • Batteries: 4 Batteries 1.5V type AA
  • Autonomy: 200 hours with 1800mAh alkaline batteries
  • Current consumption with instrument off: 20μA
  • Main: 12Vdc / 1000mA Output main adapter
  • Serial interface RS232C:
  • Type: RS232C galvanically isolated
  • Baud rate: can be set from 1200 to 38400 baud
  • Data bit: 8
  • Parity: None
  • Stop bit: 1
  • Flow Control: Xon/Xoff
  • Serial cable lenght: Max 15m
  • Print interval: Immediate or selectable among: 1,5,10,15,30 s; 1,2,5,10,15,20,30 min.; 1 hour
  • USB interface model HD2108.2 and HD2128.2:
  • Type: 1.1 - 2.0 galvanically isolated
  • Connections: 
  • Probes input:  2-pole female polarized standard miniatur connector
  • Serial interface: 8-pole MiniDin connector
  • USB interface: Type B Mini USB connector
  • Mains adapter: 2-pole connector (positive at centre)
  • Operating conditions:
  • Operating Temperature: -5...50°C
  • Storage temperature: -25 … 65°C
  • Working relative humidity: 0 … 90%RH, no condensation
  • Protection degree: IP66
  • General characteristics:
  • Dimensions (Length x Width x Height): 185x90x40mm
  • Weight: 470g (complete with batteries)
  • Materials: ABS, rubber
  • Display: 2 rows 4½ digits plus symbols
  • Visible area: 52x42mm
  • Time:
  • Date and time in real time
  • Accuracy 1min/month max drift

  • HD2108.1:
  • (1) HD2108.1
  • (4) 1.5V alkaline batteries
  • (1) Instruction manual
  • (1) Case
  • (1) Deltalog9 software downloadable from Delta OHM website.
  • NOTE: Probes and cables have to be ordered separately.
  • HD2108.2:
  • (1) HD2108.2 data logger
  • (4) 1.5V alkaline batteries
  • (1) Instruction manual
  • (1) CP23 USB cable
  • (1) Case
  • (1) Deltalog9 software downloadable from Delta OHM website.
  • NOTE: Probes have to be ordered separately

Note: Prices are not binding at any time subject to change without prior notice