Chauvin Arnoux CA 1823 [P01654823] 1-Channels RTD Thermometer Data Logger, -100 to + 400°C (-148 to + 752°F) Sensor Type PT100 & PT1000

Not yet rated Write a review
Chauvin Arnoux
Rp.14.814.505
Availability:
2 - 4 WEEKS
Product Code:
P01654823
Brand:
Chauvin Arnoux
Update Terakhir:
03 Dec 2024
This product has a minimum quantity of 2
  • Free delivery

  • Money back guarantee

Ask an Expert

Our tech experts are ready to help!

(62) 021-53167044 | 0812-83861970 | 0812-9915277

Email Us

Share

Chauvin Arnoux CA 1823 [P01654823] 1-Channels RTD Thermometer Data Logger, -100 to + 400°C (-148 to + 752°F) Sensor Type PT100 & PT1000. Chauvin Arnoux's CA1823 is a single input, simple-to-use, logging digital thermometer ideal for use in many different temperature applications. Compatible with Pt100 and Pt1000 resistance probes, the uses for the CA1823 depend entirely on which probe is used; for example, you could use an air probe to measure air temperatures, or a surface probe to measure the temperature of a specific surface. This is a datalogging digital thermometer - you can configure the sampling rate (the time at which the measurements are logged) as well as set start/end times for the logging session using Chauvin Arnoux's software. You can then simply mount the CA1823 in an area where you need to measure (it even includes a built-in magnet for hands-free mounting) and leave it to log over the time period. Once done, plug the thermometer into your PC by USB or over wireless using Bluetooth, download the results and analyse your findings using the software package. Up to 1 million individual records can be stored in the CA1823's internal memory and thanks to exceptional long battery life of up to 3 years in recording mode, this thermometer is ideal for any lengthy logging session. This digital thermometer also includes a backlit LCD display the ability to set alarm thresholds with visual alerts or triggered recording when the limits are exceeded.

There are no reviews for this product.

Write a review

  • Part Number: P01654823
  • 1-Channel
  • Measurement range: - 100 to + 400°C (-148 to + 752°F)
  • Handheld, easy-to-use digital thermometer designed for use with Pt100 and Pt1000 temperature sensors (sold separately)
  • Single input - one port for attachment of one probe
  • Datalogging thermometer - store up to 1 million records in internal memory and download to PC via USB or Bluetooth
  • User-configurable logging rate from 1 minute to 2 hours
  • Set a programmed start and end date for logging sessions
  • Adjustable alarm thresholds with visual alerts and triggered recording
  • MIN/MAX function calculates maximum and minimum values over a period of time
  • Data hold function temporarily freezes current values shown on the screen
  • Built-in backlight for use in poor lighting conditions
  • Automatic power off function (can be adjusted and disabled)
  • Built-in intergral magnet for hands-free mounting on a metallic surface
  • Extra-long battery life of up to 3 years in recording mode on a 15 minutes interval

  • Resistance thermometer (1 channel): Pt100, Pt1000
  • Measurement range: - 100 to + 400°C-148 to + 752°F
  • Resolution: 
  • Display in °C : 0.1°C; Display in °F : 0.1°F
  • Intrinsic uncertainty in °C: ± (0.4% R + 0.3°C)
  • FUNCTIONS:
  • Recording:
  • Manual start/stop on the product
  • Short press on MEM: spot recording / Long press on REC: recording at the rate of the current mode
  • Programmed recording
  • Start date, recording rate (From 1 second to 1 hour) and end date can be customized with the PC software
  • Alarms: Alarm thresholds set using the software. Visual alert on the product in the event of an overrun. Recording can be triggered on alarm thresholds
  • Data storage: More than 1 million points
  • Min-Max-Hold: Yes
  • Differential measurement: C.A 1822 only
  • Units: °C or °F
  • Backlighting: Yes
  • Automatic power off: Yes (configurable)
  • POWER SUPPLY:
  • Type: 3 x 1.5V AA / LR6 alkaline batteries. Mains connection possible with the mains / micro USB adapter proposed as an accessory
  • Battery life: C.A 1821 & C.A 1822: 1,000 hrs (portable mode) C.A 1823 : 800 hrs (portable mode). 3 years for recording (15-minute measurement interval) 
  • PHYSICAL SPECIFICATIONS: 
  • Interfaces: 2 possible communication modes: Bluetooth and USB
  • Fixations: Casing equipped with a magnet, a wall-mount system and a slot for suspension of the product. Compatible with the Multifix accessory. Sheath available as an accessory
  • Connections: C.A 1821 and 1822: compensated miniature female connectors. 
  • Dimensions / weight: 150 x 72 x 32 mm / 260 g with batteries
  • Ingress protection: IP54 casing
  • Product operating range: Temperature from -10 to +60 ° C / Humidity from 10 to 90 %RH
  • Standards: IEC61010-1 / IEC 61326-1 
  • GENERAL SPECIFICATIONS:
  • Windows Data Logger
  • Transfer software functions
  • Real-time mode
  • Automatic report generation in Word format
  • Data format compatible with the Dataview software
  • Graph or value-table presentation
  • Data export in graph or Excel table format

  • (1) CA1823 - Thermometer
  • (1) Carrying Bag
  • (3) 1.5V AA Alkaline Batteries
  • (1) USB Cable
  • (1) Test Report
  • (1) Quick Startup Guide

Download

Note: Prices are not binding at any time subject to change without prior notice


  Options 0 Item Selected
Image
Model
Product Name
Price
Available
Quantity
Chauvin Arnoux CA 1823 [P01654823] 1-Channels RTD Thermometer Data Logger, -100 to + 400°C (-148 to + 752°F) Sensor Type PT100 & PT1000
P01654823
Rp.14.814.505
2 - 4 WEEKS
Chauvin Arnoux CA 1821 [P01654821] 1-Channel Thermometer Data Logger, -200 °C to 1372 °C Sensor Type J, K, T, N, E, R, S
P01654821
Rp.12.901.330
2 - 4 WEEKS
Chauvin Arnoux CA 1822 [P01654822] 2-Channels Thermometer Data Logger, -200 °C to 1372 °C Sensor Type J, K, T, N, E, R, S
P01654822
Rp.14.814.505
2 - 4 WEEKS