The Triplett Model 9065 is a 4-5/6 digit (60000 count) true rms data logger. It offers a large variety of measurement features including AC/DC Voltage, AC/DC Current, Resistance, Continuity, Diode Test, Temperature, Frequency and the ability to record up to 20,000 measurements. The rubberized overmold provides sure grip and drop resistance. The high contrast display makes it easy to see at a distance or in dark locations and with a powerful rechargeable lithium-ion battery it can last for days. Overall, the Model 9065 is well suited for industrial applications that require a full featured data logger.
30% faster programming speed compared to SuperPro 5000 with ARM9 MCU Processor + Linux ultra-fast algorithm processing engine
Support files up to 256 GBytes
Built with 144 universal pin-drivers. Universal adapters are available for various package types up to 144 pins. More efficient for new device support
Stand-alone mode (No PC required) and PC hosted mode
Under PC hosted mode the programmer is controlled by a PC via USB2.0 (high speed) to program a chip
Under stand-alone mode, the programmer is controlled via the 6-KEY keypad and the 20 character by 4 line LCD display
A CF (compact flash) card is used to store the project files
Cluster 1-15 units for flexible volume production. Operate multiple units to construct a concurrent multi-programming system
ISP / ICP programming capability available via ISP / ICP adapter
Over-current and over-voltage protection for safety of the chip and programmer hardware
Compatible with Windows XP / Vista / 7 / 8 (32/64 bit)
Only IC manufacturer approved programming algorithms used for high reliability
Vcc verification at (+5%~-5%) and (10%~-10%) enhances programming reliability
Advanced and powerful software functions:
Production mode start chip operation the moment the chip is inserted properly
Project function simplifies processes such as Device Selection, File Loading, Device Configuration Setting, Program Option, and Batch File Setting into one step
Password for project files can be set for volume production control
Batch command combines device operations like Program, Verify,and Security into a single command at any sequence
Serial numbers generators are available as standard or customer-specific functions