• Delta Ohm HD2001 Relative Humidity, Temperature, Barometric Pressure, Air Speed Trasmitters with Display

Delta Ohm HD2001 Relative Humidity, Temperature, Barometric Pressure, Air Speed Trasmitters with Display

Not yet rated Write a review
Delta Ohm

Available Options

Rp.22.129.120
Availability:
4 - 6 WEEKS
Product Code:
HD2001
Brand:
Delta Ohm
Update Terakhir:
30 Jul 2023
  • Free delivery

  • Money back guarantee

Share

The devices of the HD2001 series…, according to the models, measure temperature,relative humidity, barometric pressure and air speed by hot-wire probes. All the models areprovided with RS232C or RS485 serial output and the management of more than one deviceconnected to a network. In addition, all the models are fitted with an open collector typelow-activated configurable alarm output.The HD2001.1 and HD2001.3 model have three configurable analog outputs: 4…20mA or0…20mA current output, or 0…10Vdc or 2…10Vdc voltage output. The choice of output typeis made by means of the jumpers set on the board.Wind speed measurement is detected by the HD2001.2 model with a hot-wire probe set onthe upper part of the instrument.The large display with dual indication on all models allows one of the process variables on thefirst line and the temperature on the second line, to be displayed.

Model HD2001.2
The HD2001.2 model is fitted with an omnidirectional hot-wire probe: the sensor set on thetop of the probe is very delicate and must be protected with the special frame provided withthe instrument. During transportation, the sensor is closed into a cylinder screwed on the endpart of the probe: during installation, unscrew this cylinder and screw the protection frame inits place.In order to measure the wind speed accurately, the instrument must be set at a certaindistance from the wall using the HD2001.2.30 pole.

ORDERING CODES: 
#HD2001: Temperature, relative humidity, barometric pressure indicator. Open collector alarmoutput and RS232C and RS485 PC connection. DeltaMet8 software for PC connectiondownloadable from Delta OHM website.
#HD2001.1: Active indicator/transmitter of temperature, relative humidity, barometric pressurewith selectable 0…20mA, 4…20mA, 0…10V e 2…10V outputs. Open collector alarmoutput and RS232C and RS485 PC connection. DeltaMet8 software for PC connectiondownloadable from Delta OHM website.
#HD2001.2: Temperature, relative humidity, barometric pressure and wind speed indicator.Open collector alarm output and RS232C and RS485 PC connection. DeltaMet8software for PC connection downloadable from Delta OHM website.
#HD2001.2.30: Wall mounting support for HD2001.2.
#HD75: Saturated salt solution 75% R.H. Adapter M 12x1.
#HD33: Saturated salt solution 33% R.H. Adapter M 12x1

  • Temperature:
  • Sensor NTC 10kΩ
  • Measuring range -20…+80 °C
  • Accuracy ±0.3 °C in the range 0…+70 °C ±0.4 °C elsewhere
  • Humidity:
  • %RH measuring range 0…100 %RH
  • TD measuring range -20…+80 °C
  • Accuracy ±1.5 %RH (0…90% RH), ±2 %RH (elsewhere) For T=15…35 °C; ±(1.5+1.5% of the measure)%RH in the remaining temperature range
  • Pressure:
  • Measuring range 600…1100 mbar - 600…1100 hPa - 60…110 kPa
  • Accuracy ±0.5 mbar @25 °C
  • Temperature drift <1%f.s. (zero); < 1%f.s. (span); From -20°C to +80 °C
  • Long-term stability <1 mbar/year at 20 °C
  • Fluid contacting the membrane Air – Non corrosive gas - No liquids
  • Wind speed*:
  • Type of sensor Hot-wire
  • Measuring range 0…5 m/s
  • Accuracy  ±0.15 m/s @25 °C

  • Temperature:
  • Sensor: NTC 10kΩ
  • Measuring range; -20…+80 °C
  • Accuracy : ±0.3 °C in the range 0…+70 °C ±0.4 °C elsewhere
  • Humidity:
  • %RH measuring range: 0…100 %RH
  • TD measuring range: -20…+80 °C
  • Accuracy : ±1.5 %RH (0…90% RH), ±2 %RH (elsewhere) For T=15…35 °C; ±(1.5+1.5% of the measure)%RH in the remaining temperature range
  • Pressure:
  • Measuring range: 600…1100 mbar - 600…1100 hPa - 60…110 kPa
  • Accuracy : ±0.5 mbar @25 °C
  • Temperature drift : <1%f.s. (zero); < 1%f.s. (span); From -20°C to +80 °C
  • Long-term stability: <1 mbar/year at 20 °C
  • Fluid contacting the membrane: Air – Non corrosive gas - No liquids
  • Wind speed*:
  • Type of sensor:  Hot-wire
  • Measuring range: 0…5 m/s
  • Accuracy:   ±0.15 m/s @25 °C
  • Outputs:
  • Communications: 
  • Type: RS232C and Multidrop RS485
  • Maximum Baud Rate: 9600 baud
  • Alarm:
  • Type of output: Open collector (low-activated)
  • Maximum voltage: 30 Vdc
  • Maximum power: 200mW
  • Variables: 
  • #HD2001.1 : Temperature, %RH, dew point TD, barometric pressure, pressure drop. 
  • #HD2001.2 : Temperature, %RH, dew point TD, barometric pressure, pressure drop and wind speed
  • Analog:
  • Type of outputs: 
  • #HD2001.1 : 4…20 mA; 0…20 mA; 0…10 Vdc; 2…10 Vdc
  • Load resistance:
  • #HD2001.1 : Current output: 500Ω max; Voltage output: 100kΩ min
  • Resolution: 
  • HD2001.1 : 16 bit
  • Power:  24 Vac ±10% 50…60Hz (230 Vac ±10% on request)
  • Software: DeltaMet8
  • Environmental conditions:
  • Temperature: range: -20…+80 °C
  • Humidity range: 0…90 %RH - (without condensation)
  • Protection degree Electronic: IP67
  • *HD2001.2



  • (1) HD2001 Transmitter
  • (1) DeltaMet8 software for PC connection downloadable from Delta OHM website.
  • (1) Instruction Manual

Note: Prices are not binding at any time subject to change without prior notice