The GF Signet 9950 Transmitter is a two channel controller that can support two sensors of same or different types in one instrument. The sensor types supported by the 9950 are Signet Flow, pH/ORP, Conductivity/Resistivity, Salinity, Temperature, Pressure, Level, Dissolved Oxygen, and devices that transmit a 4 to 20 mA signal with the use of the 8058 iGoR Signal Converter. The 9950 includes advanced features such as derived functions, advanced multiple relay modes, and timer based relay functions. Derived functions allows for the control of a relay or current loop with the sum, delta (difference), or ratio of two measurements, for example delta pressure and delta temperature. Multiple relay modes allow up to three signals to be used for the control of a single relay. This can be any combination of analog and binary inputs. The timer relay modes allow relay to be activated on a repeating basis from every minute to once every 30 days. Weekday timer mode allows a relay to be turned on for specific days and times.
The GF Signet 9950 Transmitter is compatible with 3-9950.393 relay modules providing the ability to interface up to four binary inputs. The binary inputs are compatible with either open collector or mechanical contacts. The binary inputs can supply power to the four inputs or accepts powered outputs from external devices. These inputs can be used with level switches, flow switches, pressure switches or other devices. The inputs can be used to directly control the relays of the 9950 or can be used in combination with the measurement readings for advanced control of your process. Applications for the GF Signet 9950 Transmitter include:
Two diff erent sensor types can be combined in one unit
Configurable display
Derived measurements
Advanced boolean logic
Optional modules can be added for additionalcapabilities
USB Port for Field Upgrades using standard
USB Flash Drive
General:
Input Channels: Two frequency or S3L inputs
Enclosure and Display:
Case Material: PBT
Window: Shatter-resistant glass
Keypad:4 buttons, injection-molded silicone rubber seal
Display: Dot matrix, LCD
Indicators: Two horizontal digital bar graphs, four LED relay status indicators
Update Rate: 1 s
LCD: Contrast 5 settings
Size: ¼ DIN
Mounting:
Panel: ¼ DIN, ribbed on four sides for panel mounting clip inside panel, silicon gasket included
Wall: Large enclosure (sold as an accessory
Terminal Blocks:
Pluggable Screw Type: Use minimum 105 °C rated wire
Torque Ratings:
Power/Loop: 0.49 Nm (4.4 lb-in.)
Freq/S3L: 0.49 Nm (4.4 lb-in.)
Relay Module: 0.49 Nm (4.4 lb-in.)
Connector Wire Gauge:
Power, Loop: 12 to 28 AWG
Freq/S3L: 16 to 28 AWG
Relay Module Connector Wire Gauge:
Relay 12 to 28 AWG
Ambient Operating Temperature:
DC Power: -10 °C to 70 °C (14 °F to 158 °F)
AC Power: -10 °C to 60 °C (14 °F to 140 °F)
Storage Temp -15 °C to 70 °C 5 °F to 158 °F
Relative Humidity: 0 to 100% condensing for (front only); 0 to 95% non-condensing (rear panel)
Maximum Altitude: 4,000 m (13,123 ft)
Enclosure Rating; NEMA 4X/IP65 (front face only)
Performance Specifications:
System Accuracy: Primarily dependent upon the sensor
System Response: Primarily dependent upon the sensor. Controller adds a maximum of 150 ms processing delay to the sensor electronics. Minimum update period is 100 ms. System response is tempered by the display rate, output averaging and sensitivity feature
Electrical Requirements:
Power to Sensors: Voltage +4.9 to 5.5 VDC @ 25 °C, regulated; Current 30 mA Maximum
Short Circuit: Protected
Isolation: Low voltage (< 48 V AC/DC)
Power Requirements:
DC (3-9950-1, 3-9950-2): 24 VDC nominal (10.8 to 35.2 VDC regulated)
AC (3-9950-2): 100 to 240 VAC, 50 to 60 Hz, 24 VA
Maximum current: 200 mA (without optional relay module)*; 500 mA (with optional relay module)*
*The current draw of the other modules and the sensors are minimal
Current Loop: 10.8 to 35.2 VDC 4 to 20 mA (30 mA max.)
Overvoltage protection: 48 Volt Transient Protection Device (for DC ONLY)
Current limiting for circuit protection
Reverse-Voltage protection
Input Types:
Digital (S3L) or AC frequency
4 to 20 mA input via the 8058
Open collector
pH/ORP input via the Digital (S3L) output from the 2750 pH/ORP Sensor Electronics
Conductivity/Resistivity via the Digital (S3L) output from the 2850 Conductivity/Resistivity Sensor Electronics
Sensor Types: Flow, pH/ORP, Conductivity/Resistivity, Pressure, Temperature, Level/Volume, Salinity, Dissolved Oxygen, Other (4 to 20 mA)
Sensor Input Specifications:
Digital (S3L): Serial ASCII, TTL level, 9600 bps
Frequency Flow Sensors: 0.5 to 1500 Hz
Sensitivity(for coil type sensors): 80 mV @ 5 Hz, gradually increasing with frequency to 2.5 V
Freq. Range (for square wave type sensors): 0.5 Hz to 1500 Hz @ TTL level input or open collector