Delta Ohm HD208 Compact Data Logger Temperature / Relative Humidity / Dew Point Monitoring

Not yet rated Write a review
Delta Ohm

Available Options

Rp.9.233.440
Availability:
2 - 4 WEEKS
Product Code:
HD208
Brand:
Delta Ohm
Update Terakhir:
30 Jul 2023
  • Free delivery

  • Money back guarantee

Share

The data loggers of the series HD208 are compact instruments for monitoring temperature, relative humidity (RH) and dew point temperature. Usable in a wide spectrum of applications, are available in various models:

  • With 1 channel for temperature only (depending on the model, the sensor can be internal, external fixed or external with cable).
  • With 1 channel for temperature and relative humidity (combined probe fixed or with cable).

All models can be supplied with or without LCD display.

The logging function is extremely versatile; logging can be started and stopped manually, by means of the front buttons, or the start and stop date and time of acquisition can be programmed. The delayed start capability allows starting the logging with a configurable delay time after pressing the button for the manual start.

For each quantity detected, two configurable alarm thresholds can alert the user if the measure exceeds the configured parameters.

The instrument automatically generates, after logging, a PDF report with charts of the variables collected and a CSV file with all measurements logged. The PDF and CSV files can then be copied to the PC via the USB port, without any dedicated software: the instrument is recognized as a USB flash drive.

The application software HD35AP-S, downloadable from Delta OHM website, allows the configuration of the instrument, the real-time monitor of the measurements and the transfer of the acquired data into a database. The connection to the PC does not require any installation of USB drivers, thereby ensuring compatibility with all versions of the Windows® operating system.

The HD35AP-CFR21 application software option allows the use of security features of the recorded data and configuration of the instrument in response to FDA 21 CFR part 11 recommendations. Powered by a 3.6 V non rechargeable lithium-thionyl chloride battery (Li-SOCl2). The sensors are pre-calibrated and require no further calibration by the user. If necessary, the user can perform a new calibration using the HD35AP-S application software. All versions can be ACCREDIA certified, upon quote. 

  • KEEP TRACK OF YOUR MEASUREMENTS. Monitor & record of temperature & humidity all along the process
  • MODELS FOR ANY APPLICATION. Only temperature or combined with RH Internal sensor or external probe, fixxed or with cable
  • LOGGING FUNCTION EXTREMELY VERSATILE. Manual, automatic or delayed start and stop of the logging
  • MEASURED DATA DIRECTLY AVAILABLE PDF report with charts and CSV file automatically generated
  • FACTORY CALIBRATED AND READY TO USE. Pre-calibrated sensors No further calibration required

  • RELATIVE HUMIDITY:
  • Sensor: Capacitive
  • Measuring range: 0…100% RH
  • Resolution: 0.1% RH
  • Accuracy: ± 1.5% RH (0…85% RH) / ± 2.5 %RH (85…100 %RH) @ T=15…35 °C; ± (2 + 1.5% measure)% @ T=remaining range
  • Sensor operating temperature:  -40…+80 °C
  • Response time: T90 < 20 s (air speed 2 m/s, without  lter)
  • Temperature drift:  ±2% over the whole operating temperature range
  • Stability: 1% / year
  • TEMPERATURE: 
  • Sensor: NTC10kΩ @ 25 °C
  • Measuring range: -40…+105 °C*
  • Resolution: 0.1 °C
  • Accuracy : ± 0.3 °C in the range 0…+70 °C; ± 0.4 °C outside
  • Long-term stability: 0.1 °C / year 
  • GENERAL SPECIFICATIONS:
  • Logging interval: 1, 2, 5, 10, 15, 30 s / 1, 2, 5, 10, 15, 30, 60 min
  • Storable quantities: According to the model: Temperature - Mean Kinetic Temperature (MKT) - Relative Humidity - Dew Point - Battery Voltage
  • Memory: Flash memory with circular management or stop logging when full
  • Alarms: Two alarm thresholds (configurable) for each measured quantity
  • Power supply: 3.6 V not rechargeable lithium-thionyl chloride internal battery (Li-SOCl2), size AA, 2-pole Molex 5264 connector
  • Battery life : 2 years typical, with logging interval 30 s
  • PC connection USB port with mini-USB connector
  • Operating conditions: -40…+75 °C / 0…100 %RH non condensing
  • Material: ABS (with added UV filters)
  • Protection Degree IP: 64
  • Weight : 150 g approx.
  • Installation:  Wall mount

  • (1) HD208 Data logger
  • (1) USB cable CP 23 to obtain the measurement data
  • (1) HD35AP-S software downloadable from Delta OHM website
  • (1) User manual

Note: Prices are not binding at any time subject to change without prior notice