Delta Ohm HD2106 Conductivity-Thermometer

Not yet rated Write a review
Delta Ohm

Available Options

Rp.11.545.120
Availability:
2 - 4 WEEKS
Product Code:
HD2106
Brand:
Delta Ohm
Update Terakhir:
05 Aug 2023
  • Free delivery

  • Money back guarantee

Share

The HD2106.1 and HD2106.2 are portable instruments with a large LCD display. They measure conductivity, liquid resistivity, total dissolved solids (TDS) and salinity using combined 4-ring and 2-ring conductivity/temperature probes. Temperature only is measured by Pt100 or Pt1000 immersion, penetration or contact probes.

The probe calibration can be performed automatically in one or more of the 147 µS/cm, 141 3µS/cm, 12880 µS/cm or 111,800 µS/cm conductivity calibration solutions.

The temperature probes are automatically detected by the instrument upon turning on.

The HD2106.2 is a datalogger. It memorizes up to 36,000 conductivity and temperature samples that can be transferred from the instrument connected to a PC via the RS232C serial port or USB 2.0 port. The storing interval, printing, and baud rate can be configured using the menu.

The HD2106.1 and HD2106.2 models are fitted with an RS232C serial port and can transfer the acquired measurements to a PC or to a portable printer in real time.

Display, printing and logging (model HD2106.2) always include temperature in °C or °F, and one of the parameters of conductivity measure (χ or Ω or TDS or NaCl).

The Max, Min and Avg function calculates the maximum, minimum or average values. Other functions include the relative measurement REL, the Auto-HOLD function, and the automatic turning off which can also be disabled.The instruments have IP66 protection degree.

  • Conductivity-Thermometer measures conductivity
  • Liquid resistivity, total dissolved solids
  • Salinity and temperature.
  • Storage of maximum, minimum, average value.
  • RS232C output for data transfer in real time to a PC or printer.
  • Functions: REL, HOLD and auto power off which can be disabled
  • Datalogger which can store the maximum, minimum, average value and can store up to 36,000 samples.
  • USB output for data transfer in real time to a PC
  • IP 66 protection degree


  • Measurement of conductivity by Instrument:
  • Measurement range (K cell=0.1): 
  • Resolution:  0.00 - 19.99μS7cm / 0.01μS/cm (with K cell=0.1); - 0.0 - 199.9μS/cm / 0.1μS/cm; 200 - 1999μS/cm / 1μS/cm; 2.00 - 19.99mS/cm / 0.01mS/cm; 20.0 - 199.9mS /cm / 0.1mS/cm
  • Accuracy (conductivity): ±0.5% ±1digit
  • Measurement of resistivity by Instrument : 
  • Measurement range / Resolution:  4.0 - 199.9Ω / 0.1Ω; 200 - 999Ω / 1Ω; 1.00k - 19.99kΩ / 0.01kΩ; 20.0k - 99.9kΩ / 0.1kΩ; 100k - 999kΩ / 1kΩ; 1 - 10MΩ / 1MΩ 
  • Accuracy (resistivity):  ±0.5% ±1digit 
  • Measurement of total dissolved solids (with coefficient χ/TDS=0.5): 
  • Measurement range (K cell=1)  : 0.00 - 19.99mg/l / 0.05mg/l 
  • Resolution  : 0.0 - 199.9 mg/l / 0.5 mg/l (with K cell=0.1); 200 - 1999 mg/l / 1 mg/l; 2.00 - 19.99 g/l / 0.01 g/l; 20.0 - 199.9 g/l / 0.1 g/l 
  • Accuracy (total dissolved solids)  : ±0.5% ±1digit 
  • Measurement of salinity: 
  • Measurement range / Resolution : 0.000 - 1.999g/l / 1mg/l; 2.00 - 19.99g/l / 10mg/l 
  • Accuracy (total dissolved solids) :±0.5% ±1digit 
  • Measurement of temperature by Instrument: 
  • Pt100 measurement range : -50 - +200°C 
  • Pt1000 measurement range : -50 - +200°C 
  • Resolution : 0.1°C 
  • Accuracy : ±0.25°C 
  • Drift after 1 year : 0.1°C/year 
  • Temperature compensation automatic/manual: 0…100 °C with αT selectable from 0.00 to 4.00%/ °C
  • Reference temperature: 20 °C o 25 °C
  • χ / TDS conversion factor: 0.4…0.8
  • Preset cell constant values: (cm-1): K=0.01 K=0.1 - K=0.7 - K=1 - K=10
  • Standard solutions automatically detected @25°C: 147 µS/cm; 1413 µS/cm; 12880 µS/cm; 111800 µS/cm
  • Power Supply:
  • Batteries: 4 1.5V type AA batteries
  • Autonomy: 200 hours with 1800 mAh alkaline batteries
  • Power absorbed with instrument off: 20 μA
  • Mains (SWD10): Output mains adapter 12 Vdc / 1A
  • Security of memorized data: Unlimited, independent of battery charge conditions
  • Measured values storage - model HD 2106.2:
  • Type: 2000 pages containing 18 samples each
  • Quantity:  36000 pairs of measurements [χ-°C], [Ω-°C], [TDS-°C] or [Sal-°C]
  • Selectable storage interval: 1, 5, 10, 15, 30 s; 1, 2, 5, 10, 15, 20, 30 min 1 hour
  • USB interface - model HD 2106.2:  Type: 1.1 - 2.0 electrically isolated
  • Connections: 
  • Temperature input: 8-pole male DIN45326 connector
  • Conductivity input: 8-pole male DIN45326 connector
  • Serial interface and USB: 8-pole MiniUSB type B
  • Mains adapter: 2-pole connector (positive at centre)
  • Time: 
  • Date and time: in real time
  • Accuracy: 1min/month max error
  • Operating conditions
  • Working temperature -5…50 °C
  • Storage temperature -25…65 °C
  • Working relative humidity 0…90% RH without condensation
  • Protection degree IP66
  • Instrument: 
  • Dimensions (Length x Width x Height): 185 x 90 x 40 mm
  • Weight: 470 g (complete with batteries)
  • Material: ABS, rubber
  • Display: 2x4½ digits plus symbols. Visible area: 52x42 mm

  • HD2106.1:
  • (1) HD2105.1
  • (4) 1.5V alkaline batteries
  • (1) Operating manual
  • (1) Case
  • (1) DeltaLog9 software downloadable from Delta OHM website.
  • NOTE: Conductivity probes, calibrating solutions, TP47… series temperature probes with SICRAM module and cables for data download have to be ordered separately.
  • HD2106.2:
  • (1) HD2105.2 data logger
  • (4) 1.5V alkaline batteries
  • (1) USB cable CP23
  • (1) operating manual
  • (1) Case
  • (1) DeltaLog9 software downloadable from Delta OHM website
  • NOTE: Conductivity probes, calibrating solutions, TP47… series temperature probes with SICRAM module and cables for data download have to be ordered separately.