The F400-series are equipped with a higher degree of protection for higher low voltages and are thus used especially in the maintenance, testing, monitoring and analysis of systems of medium power.The F405 clamp is equipped with a fast, digital 12-bit TRMS detection system for high measurement accuracy regardless of the waveform.

There are no reviews for this product.

Write a review

  • Clamping diameter: 48 mm
  • Current: 1,000 A AC / 1,500 A DC
  • AC and DC voltage up to 1000 V
  • Resistance and audible continuity
  • Power values (W, var, VA, PF) and harmonics (THDf, THDr)
  • "2-wire method" phase rotation
  • Automatic AC/DC detection
  • TrueInrush current measurement
  • Min, MAX, Peak+, Peak: Yes
  • RELative (ΔX) and differential (ΔX/X) measurements
  • CAT IV 1,000 V
  • IP54 protection rating

  • Clamping diameter: 48 mm
  • Display: Backlit LCD
  • Resolution: 10,000 counts
  • Number of values displayed: 1
  • Type of acquisition: TRMS [AC, AC+DC]/DC
  • Autorange: Yes
  • Automatic AC / DC detection:  - 
  • A AC: 0.25 to 1,000 A (1,500 A peak)
  • A DC:  0.25 to 1500 A
  • A AC+D:  0.25 to 1,000 A (1,500 A peak)
  • Best accuracy: 1 % L. + 3 cts
  • V AC:  0.15 to 1,000 V
  • V DC: 0.15 to 1,000 V
  • V AC+DC:  0.15 to 1,000 V
  • Best accuracy:  1 % reading + 3 cts
  • Hz: Current: Current: 5.0 Hz to 2,000 Hz; Voltage: 5.0 Hz to 20.00 kHz
  • Ohm: 0.1 Ω to 99.99 kΩ
  • Open-circuit voltage: ≤ 8 V
  • Measurement current: ≤ 680 µA
  • Audible continuity: Yes
  • Continuity threshold: adjustable from 1 to 999 Ω
  • Diode test (semiconductor junction): Yes
  • Temperature (K type):  -
  • Single-phase and total three-phase power values: Yes
  • Active power:  1 W to 1,000 kW
  • Reactive power: 1 var to 1,000 kvar
  • Apparent power: 1 VA to 1,000 kVA
  • FP / DPF: Yes / No
  • Harmonic analysis: Yes
  • THDf / THDr:  Yes / Yes
  • Frequency analysis: No
  • Phase rotation (2-wire method): Yes
  • Functions:
  • True InRush (Overcurrent measurement): Yes
  • Motor inrush: Yes
  • Load change: Yes
  • Hold: Yes
  • Min. / Max.: Yes
  • Peak+ / Peak: -
  • RELative ∆X / Differential ∆X/X (%): Yes
  • Auto Power Off: Yes
  • Data recording: -
  • Communication interface: -
  • Electrical safety as per IEC 61010: 1,000 V CAT IV & CAT III 
  • Power supply: 4 x 1.5 V AA
  • Dimensions & weight: 92 x 272 x 41 mm / 600 g

  • (1) Chauvin Arnoux F405  Clamp Meter
  • (4) AA batteries
  • (1) Case
  • (1) Drop-like K-type temperature probe
  • (1) Test leads
  • (1) Test probes