Badger Meter Model 330-00 Programmable Relay Control (Transmitter Only)capable of converting the signal from Badger Meter flow sensors into a flow switch. The 330 accepts both square wave and sine wave signals as well as pulse inputs making it a versatile transmitter for numerous applications.

With an onboard micro-controller and digital circuitry, the 33000 meter is programmed from a computer which eliminates the need to set dip switches or potentiometers and produces precise, accurate and drift free control of the relay outputs. The relay outputs consist of a pair of single pole relays, one normally open and one normally closed. Both relays act in unison to the programmed parameters. Features of the Badger 33000 include selectable alarm type, programmable set and release points, programmable time delays, a latch feature and remote reset.

The Badger Meter Model 33000 pulse transmitter features a compact cast epoxy body that can easily be mounted to panels, DIN rails or enclosures. With multiple inputs, ease of use and a variety of enclosures, Model 33000 meters are a powerful and competitively priced transmitter for many of today's demanding applications.

  • Part Number: 330-00
  • Options: Transmitter only
  • Relay: 1 Form A, 1 Form B
  • Multiple inputs
  • Selectable alarm type
  • Programmable set and release points
  • Programmable time delays
  • Latch feature
  • Remote reset
  • Power Requirements:12-24VAC
  • 12-24VDC
  • Mounts on panels, DIN rails or enclosures
  • Size: 1.75" x 2.75" x 1"


  • Power:
  • Power Supply Options:
  • 12…28V AC RMS, 200mA max
  • 12…40V DC, 100mA max
  • Flow Sensor Input:
  • All Sensors Excitation voltage 3 wire sensors: 9.1 V DC 500 Ω source impedance
  • Pulse Type Sensors:
  • Signal Amplitude: 2.5V DC threshold
  • Signal Limits: Vin < 35V (DC or AC peak)
  • Frequency: 0…10 kHz
  • Pull-up: 2 kΩ
  • Sine Wave Sensors:
  • Signal Amplitude: 10 mV p-p threshold
  • Signal Limits: Vin < 35V (DC or AC peak)
  • Frequency: 0…10 kHz
  • Relay:
  • 1 form A, 1 form B
  • Contact Ratings:
  • 5A @ 30V DC
  • 5A @ 125V AC
  • 5A @ 250V AC
  • Time Delay: 
  • 1…9999 second delay between flow point and relay actuation
  • Transient Suppression:
  • Designed to withstand a 5000 volt, 1/2 microsecond, 100 kHz ring wave
  • Sensor Calibration:
  • Badger Meter Sensors Use K and Offset values provided in sensor owner's manual
  • Other Sensors Check with factory
  • Units of MeasureFlow Measurement Rate:
  • gpm, gph, I/sec, I/min, I/hr, ft3/sec, ft3/min, ft3/hr, m3/sec, m3/min, m3/hr
  • Programming:
  • Requires computer running Windows 7, XP or Vista
  • Operating Temperature:
  • –25…70°C (–20…158°F)
  • Storage Temperature:
  • –40…85°C (–40…185°F)
  • Weight:
  • 4.8 oz with headers installed
  • Accessories:
  • A301 programming kit with cable and software

  • (1) Protective storage case
  • (2) AAA Batteries
  • (1) Serialized Calibration Report certificate
  • (1) Instruction Manual.

Download