Ashcroft GC55 Wet/Wet Differential Pressure Transducer

Not yet rated Write a review
Ashcroft

Available Options

Rp.20.513.408
Availability:
4 - 6 WEEKS
Product Code:
GC55
Brand:
Ashcroft
Update Terakhir:
07 Oct 2021
  • Free delivery

  • Money back guarantee

Share

The Ashcroft GC55 wet/wet differential pressure transducer is a compact, high-differential pressure transducer ideal for filter monitoring, HVAC hydronic cooling and heating systems, and pump controls. A three wire 4 to 20mA or 1-5VDC output signal connects the transducer to external controls or data acquisition.

Ashcroft GC55 wet/wet differential pressure transducers contain two polysilicon thin film sensors with welded, stainless steel, wetted components to accommodate wet or dry pressure media up to 300 psid. A robust, cast aluminum housing features a bright LED front-panel display for local indication and switch status along with a button to allow the user to select between the dP value and the line pressure reading from either sensor. The user also has the ability to re-range the transducer and set trip points for the on-board switch contacts.

  • Replaces 3 devices: mechanical pressure gauge, transducer, and switch
  • Two sensor design for high DP ranges
  • Polysilicon thin film sensors
  • Robust, cast-aluminum NEMA 4X / IP66 enclosure
  • Bright 3-1/2 digit LED display
  • Displays pressure and switch status
  • Min / Max Hold Capability
  • Programmable switch setting and analog scaling
  • "Push Button" selection display DP both sensors, static pressure
  • Accuracy:
    • ±0.50% F.S. (analog output)
    • ±1.00% F.S. (display and switch outputs)
  • Differential Pressure Ranges:
    • 75 to 300 psid

PERFORMANCE SPECIFICATIONS
  • Accuracy: ±0.50% FS (URL) (Accuracy includes the effects of linearity, hysteresis, and repeatability)
  • Response Time: 20 msec.
  • Output Resolution 0.2% FS
  • Display: Type: 3-1/2 digit, 10mm LED
  • Accuracy: ± 1.0% FS (URL) + last digit
  • Ranges: Standard Ranges (Differential psid): 75, 100, 150, 250, 300 psid
ENVIRONMENTAL SPECIFICATIONS
  • Temperature Limits:
    • Storage: –15 to 60°C (5 to 140°F)
    • Operating: –10 to 50°C (14 to 122°F)
    • Compensated: –10 to 50°C (14 to 122°F)
    • Temperature Effects (–10 to 60°C): Zero/Span ±0.05% FS/C° (from reference, 23°C (73°F)
FUNCTIONAL SPECIFICATIONS
  • Overpressure (F.S.)
  • Maximum operating line pressure is the range (URL) of the unit ordered:
  • Static (Line) Pressure:
    • RANGE: All
    • Proof: 2X FS (URL)
    • Burst:10X FS (URL)
  • Static (Line) Pressure Effect: NONE
  • Single Side (Differential) Limits
    • RANGE: All
    • Proof: 2X FS (URL)
    • Burst:10X FS (URL)
ELECTRICAL SPECIFICATIONS
  • Output Signal (3-Wire): Choose 4-20mA or 1-5 VDC
  • Supply Voltage:
    • 4-20mA 15-27 VDC (80 mA max)
    • 1-5 VDC 11-27 VDC (60 mA max)
  • Rangeablility / Adjustment (Accuracy and output resolution based upon full scale (URL) value):
  • Zero –105% to +105% FS
  • Span –105% to +105% FS
  • Approval: CE
MECHANICAL SPECIFICATIONS
  • Pressure Connection: Two 1⁄8 inch Female NPT for high and low side
  • Enclosure Material: Aluminum
  • Enclosure Rating: NEMA 4X / IP66
  • Electrical Connection (Options): 1/2 inch Female NPT conduit or Cable Gland (Diameters 0.16 to 0.31 inch)
  • Weight: 1 lb
  • Mounting: (2) 5.2 mm mounting holes thru enclosure, accessible with cover removed
  • Media: Fluids and gases compatible with 304SS (sensor housing) and 17-4 pH SS (sensor diaphragm)

  • (1) Intsruction Manual

Download

Note: Prices are not binding at any time subject to change without prior notice