  • AEMC MN261 [2115.82] AC Current Probe, BNC, 100mV/A, 24A, 10mV/A 240A Max

AEMC MN261 [2115.82] AC Current Probe, BNC, 100mV/A, 24A, 10mV/A 240A Max

Not yet rated Write a review
AEMC
Rp.10,228,640
Availability:
2 - 4 WEEKS
Product Code:
2115.82
Brand:
AEMC
Update Terakhir:
13 Mar 2024
  • Free delivery

  • Money back guarantee

Ask an Expert

Our tech experts are ready to help!

(62) 021-53167044 | 0812-83861970 | 0812-9915277

Email Us

Share

AEMC MN261 [2115.82] AC Current Probe, BNC, 100mV/A, 24A, 10mV/A 240A Max. The MN261 is a high sensitivity probe with voltage outputs (100mV/A and 10mV/A) and combine two switch-selectable ranges of 20A and 200A, thus permitting accurate measurements at low and high levels. The MN261 is designed for oscilloscopes and other BNC terminated instruments. It has two performing ranges (20A, 200A) both voltage output (100mV/A and 10mV/A) and 40Hz to 10kHz response.

There are no reviews for this product.

Write a review

  • Part Number: 2115.82
  • Small, compact size
  • Large jaw opening accommodated conductors up to 250MCM
  • Designed for DMMs, loggers, recorders and oscilloscopes
  • Conforms to IEC1010, 600V, Cat. III

  • Operating Range:
  • RangeVal: 20A, 200A
  • Current Range: 0.1 to 24A, 0.1 to 240A
  • Frequency Range: 40 to 10kHz
  • Limit Operating Conditions: 200A permanently to 1kHz; Derating above 3kHz: 200A x (1/0.333 F), F in kHz
  • Common Mode Voltage: 600VAC
  • Crest Factor: 3 @ 200Arms with an error (due to CF) of 3%
  • Current Overload: 240A for 10 min
  • Reference Conditions: 20° to 26°C, 20 to 75% RH, 48 to 65Hz, external magnetic field <40A/m, 48 to 65Hz sine wave, distortion factor less than 1%, no DC component, no external current carrying conductor, test sample centered. Load impedance 1MW
  • Working Voltage: 600VAC
  • Influence of Adjacent Conductor: 
  • Range Value: 50Hz
  • Influence of Adjacent Conductor: < 15mA/A
  • Influence of Conductor Position:
  • Influence of Conductor Position: 0.5% of Reading @ 50/60Hz
  • Influence of Frequency:
  • Range: 20A, 200A
  • Range Value: 40Hz to 1kHz, 1 to 10kHz, 40Hz to 1kHz, 1 to 10kHz
  • Influence of Frequency 5% of mV output, 15% of mV output, 3% of mV output, 12% of mV output
  • Influence of Humidity:
  • Influence of Humidity: 13 - 90% RH: £0.2% of mV output per 10°K @ 18°C to 28°C
  • Output Signal:
  • Range Value: 20A, 200A
  • Output Signal: 100mV/A, 10mV/A
  • Mechanical Specifications:
  • Altitude: Operating: 0 to 2000m; Non-operating: 0 to 12km
  • Colors: Dark gray handles with red cover
  • Dimensions: 5.47 x 2.00 x 1.18" (139 x 51 x 30mm)
  • Drop Test: Test per IEC 68-2-32: 1.0 m drop on 38 mm of Oak on concrete
  • Jaw Opening: .84" (21mm)
  • Material:  Jaws: Polycarbonate with 10% fiberglass charge, Red UL 94 V0; Case: Polycarbonate
  • Maximum Bus Bar Size: 0.78 x 0.19" (20 x 5mm)
  • Maximum Cable Diameter: One 0.78" & Oslash; (20mm)
  • Mechanical Shock: 100g per IEC 68-2-27
  • Operating Temperature: -14° to 131°F (-10° to 55°C)
  • Operating Relative Humidity: 10° to 35°C 85% RH (without roll-off above 35°C)
  • Output: Insulated 6.5 ft (2m) coaxial cable with insulated BNC connector rated 600Vrms
  • Protection Index (IP): IP 40 (IEC 529)
  • Impact Test: IK04 0.5 J EN50102
  • Storage Temperature: -40° to 158°F (-40° to 70°C)
  • Vibration: Test per IEC 68-2-6
  • Weight: 6.5 oz (180g)
  • External Influences: 
  • Influence of Temperature:£150 ppm/°K, or 0.15% of mV output per 10K°
  • Safety Reference Specifications:
  • Safety Ratings: EN 61010-2-32

  • (1) MN261 [2115.82] Oscilloscope & BNC Terminated Probe