Multiple Product

have been added to your cart

There Are items in your cart.

Cart Subtotal: $xxx.xx

Go to checkout
  • ACR Systems SmartReader Plus 5 [01-0012] Three-Channel Temperature Data Logger With 32 KB Memory, -40°C to 70°C (-40°F to 158°F)

ACR Systems SmartReader Plus 5 [01-0012] Three-Channel Temperature Data Logger With 32 KB Memory, -40°C to 70°C (-40°F to 158°F)

Not yet rated Write a review
ACR Systems Inc.
Rp.20.912.800
Availability:
2 - 4 WEEKS
Product Code:
01-0012
Brand:
ACR Systems Inc.
Update Terakhir:
22 Nov 2023
  • Free delivery

  • Money back guarantee

Share

The ACR Systems SmartReader Plus 5 [01-0012] 3-Channel (Temperature/Cold-Junction Compensation and External Temperature) Data Logger with 32 KB Memory is ideal for those applications that require monitoring high temperatures or monitoring temperature over a wide range. The logger has one internal channel for measuring ambient temperature and two external channels for use with ACR thermocouple wire or any J, K, S, T or E type thermo couple wire. At 12-bit resolution, the SmartReader Plus 5 offers greater accuracy and more precise measurements than the SmartReader 5. APPLICATIONS: Monitor performance of gas-fired heating equipment, verifying concrete curing temperatures, process verification, etc.

TrendReader 2 Software
The ACR Systems TrendReader 2 Software is a powerful, versatile and easy-to-use application, designed exclusively for ACR's SmartReader Plus, SmartReader, IAQ, OWL, TRH, JR and Nautilus data loggers. Powerful features and easy setup enables collected data to be thoroughly analyzed in seconds.

Downloading and Communicating with Data Logger
Setup, download and view information from a single data logger with ACR's IC-102 interface cable (included in software interface package). Connection is simple; plug the interface cable into the USB port of your computer and connect the other end to the logger. No tools, cards or docking stations are required.

Data Logger Setup
With built-in menus for sample rate and mode, start delay, equations and more, logger setup is fast and easy. In addition, equations are already included for all ACR sensors so you need only select the appropriate equation from the menu or customize your own. Real-time readings are displayed in the Setup window, allowing you to verify that your data logger is working correctly before placing it in the field.

Viewing Data
With TrendReader 2, data can be viewed in several ways. For presentation purposes, view your collected data in graphical format or for a more detailed analysis, view your data in table format. Either way, multiple channels of data can be displayed at once. Multiple graphs can be displayed together and compounded to create new graphs. For added presentation power, add comments, change graph colors, zoom in on specific portions of data, and display your data using custom engineering units. Print or copy and paste graphs into your reports and presentations. Select all, or portions of the table and copy and paste into your favorite Windows program.

Exporting Data
Use the export function in TrendReader 2 to export your data to other programs for further analysis. Data can be exported in TXT, BMP, PDF, JPG or CSV formats.

  • Part Number: 01-0012
  • Internal temperature range: -40°C to 70°C (-40°F to 158°F)
  • Memory Size: 32 KB (capable of storing up to 32,767 readings)
  • (2) External Thermocouple Inputs with Additional Internal Temp Sensor for CJC
  • Accepts Type J, K, S, T or E Thermocouple Sensor Probes
  • 25/second to 8 Hour User-Selectable Sampling Rate
  • Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery
  • Continuous (FIFO) or Stop When Full Sampling Methods

                                                                                              • Size: 107mm x 74mm x 22mm (4.2” x 2.9” x 0.9”)
                                                                                              • Weight: 110 g (3.75 oz)
                                                                                              • Case Material: Noryl® Plastic
                                                                                              • Battery: 3.6 volt Lithium
                                                                                              • Resolution: 12-bit (1 part in 4096)
                                                                                              • Mounting: Magnetic backing or locking eyelet
                                                                                              • Clock Accuracy: ± 2 seconds per day
                                                                                              • Sampling Methods: Continuous (First-in First-out)*, Stop When Full (Fill-then-stop). *Not available with sample rates faster than eight seconds
                                                                                              • Operating Limits: -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing)
                                                                                              • PC Requirements: Windows PC with at least one free USB or serial port (depending on interface)
                                                                                              • Software Requirements: TrendReader® 2 (Compatible with Windows XP, Vista, Windows 7 and Windows 8  [32 bit & 64 bit])
                                                                                              • Memory Size (2 models available) : 32 KB (capable of storing up to 21,500 readings); 128 KB (capable of storing up to 87,000 readings)
                                                                                              • Sampling Rates: User selectable rates from 25 per second to once every eight hours (BP-101 battery pack or PS-201 power supply required for sampling rates faster than  eight seconds)
                                                                                              • Number of Channels: Three (one internal thermistor for cold-junction compensation and two external  channels for narrow range and wide range thermocouples
                                                                                              • Internal Temperature Sensor: 
                                                                                              • Type: NTC Thermistor - 10,000 Ohm @ 25°C (77°F)
                                                                                              • Range: -40°C to 70°C (-40°F to 158°F)
                                                                                              • Accuracy: ±0.2°C over the range of 0°C to 70°C (± 0.3°F over the range of 32°F to 158°F);
                                                                                              • Resolution: 0.03°C (0.05°F) @ 25°C; better than 0.07°C (0.12°F) between -25°C and 70°C (-13°F and 158°F); better than 0.13°C (0.23°F) between -40°C and -25°C (-40°F and -13°F)

                                                                                              • (1) SmartReader Plus 5 Data Logger
                                                                                              • (1) TrendReader 2 software and interface kit
                                                                                              • (1) Instruction manual

                                                                                                Note: Prices are not binding at any time subject to change without prior notice


                                                                                                  Options 0 Item Selected
                                                                                                Image
                                                                                                Model
                                                                                                Product Name
                                                                                                Price
                                                                                                Available
                                                                                                Quantity
                                                                                                ACR Systems SmartReader Plus 5 [01-0012] Three-Channel Temperature Data Logger With 32 KB Memory, -40°C to 70°C (-40°F to 158°F)
                                                                                                01-0012
                                                                                                Rp.20.912.800
                                                                                                2 - 4 WEEKS
                                                                                                  Accessories 0 Item Selected