Multiple Product

have been added to your cart

There Are items in your cart.

Cart Subtotal: $xxx.xx

Go to checkout
  • Ametek ETC-125A Dry Block Calibrator, -10 to 125°C

Ametek ETC-125A Dry Block Calibrator, -10 to 125°C

Not yet rated Write a review
Ametek

Available Options

Rp.118.781.600
Availability:
4 - 6 WEEKS
Product Code:
ETC125A
Brand:
Ametek
Update Terakhir:
23 Mar 2024
  • Free delivery

  • Money back guarantee

Ask an Expert

Our tech experts are ready to help!

(62) 021-53167044 | 0812-83861970 | 0812-9915277

Email Us

Share

The Ametek ETC series portable temperature calibrators are specifically designed for tests and verifications of temperature sensing devices in the field. These instruments are ideal when time is a critical factor and the highest accuracy is not a requirement. Reduced size and weight are important considerations as the units may fit into a toolbox or instrument carrying case, and can be used for sensors that are difficult to access. The Ametek ETC series includes a One-key-one-function user interface which provides immediate access to setting the temperature and the auto-step timesaving function. The stability indicator provides audible and visual prompts when the temperature is stable. This function also includes a 3-minute countdown before the stable condition. Stainless steel and rubber side panels make the instrument suitable for many years of faithful duty in an industrial environment. The Ametek ETC series includes JOFRACAL calibration software which ensures easy calibration of RTDs, thermocouples, transmitters, thermo-swithes, pressure gauges and pressure switches. JOFRACAL software controls the complete calibration procedure, stores the results and provides a calibration audit trail through hard-copy certificates. All calibration data are stored for each sensor to monitor drift and optimize recalibration intervals. A scheduler feature allows planning of future calibrations. The ETC-125A is a dry block calibrator with a temperature range of -10 to 125°C. This model is a simple yet effective tool for verifying temperature instruments that also require references below ambient temperatures: e.g. air-conditioning and cold counters. The predrilled holes allow the use of an insertion tube in the largest bore. This increases the flexibility to match many sensor-under-test sizes.

There are no reviews for this product.

Write a review

  • Dry block or Infrared target models
  • Wide temperature range: ETC-125A: -10 to 125°C; ETC-400A: 28 to 400°C; ETC-400R: 28 to 400°C
  • Heats up as quickly as 100°C per minute and stabilizes in just 3 minutes
  • Completes a 2-point test in less than 10 minutes
  • Fast one-key-one-function access
  • RS232 and JOFRACAL calibration software makes documentation easy
  • Multi information display
  • Auto stepping
  • Stability indicator
  • Count down timer (shows when unit is stable)
  • Programable maximum temperature
  • Fast simulation/training mode
  • Re-calibration from keyboard

  • Temperature range @ ambient temp. 23°C / 73°F
  • ETC-125 A
  • Maximum:  125°C / 257°F
  • Minimum @ ambient temp. 0°C / 32°F : -18°C / -0°F
  • Minimum @ ambient temp. 23°C / 73°F:-10°C /14°F
  • Minimum @ ambient temp. 40°C / 104°F : 6°C / 43°F
  • ETC-400 A : 28 to 400°C / 82 to 752°F@ 23°C
  • ETC-400 R : 28 to 400°C / 82 to 752°F@ 23°C
  • Resolution (user-selectable)
  • Selectable: 1º or 0.1º
  • Heating time:
  • ETC-125 A: -10 to 23°C / 14 to 73°F: 3 minutes; 23 to 100°C / 73 to 212°F: 11 minutes; 100 to 125°C / 212 to 257°F: 7 minutes
  • ETC-400 A / R: 28 to 200°C / 82 to 392°F: .2 minutes; 200 to 400°C / 392 to 752°F: 3 minutes
  • Cooling time: 
  • ETC-125 A: 125 to 100°C / 257 to 212°F : 1 minute; 100 to 0°C / 212 to 32°F: 17 minutes; 0 to -10°C / 32 to 14°F: 14 minutes
  • ETC-400 A: 400 to 200°C / 752 to 392°F : 6 minutes; 200 to 50°C / 392 to 122°F : 15 minutes
  • ETC-400 R: 400 to 200°C / 752 to 392°F : 9 minutes; 200 to 50°C / 392 to 122°F : 24 minutes
  • Stability: 
  • ETC-125 A: ±0.05°C / +0.09°F
  • ETC-400 A:  ±0.15°C / +0.27°F
  • ETC-400 R : ±0.3°C / ±0.54°F
  • Measured after the stability indicator has been on for 10 minutes. Measuring time is 30 minutes.
  • Time to stability (approximate): All models: 3 minutes
  • Accuracy:
  • ETC-125 A: +0.5°C / +0.9°F *
  • ETC-400 A: +0.5°C / +0.9°F *
  • ETC-400 R:  ±0.5°C / ±0.9°F **
  • ETC-400 R incl. emissivity: ±0.4% rdg ±1°C / ±0.4% rdg. ±1.8°F
  • *Specification when using the internal reference. (Load 4 mm OD reference probe in the center of the insert).
  • **Specification when using the internal reference. (Load 3 mm OD reference probe).
  • Immersion depth:
  • ETC-125 A (insulation included) :  110 mm / 4.3 in
  • ETC-400 A : 105 mm / 4.1 in
  • Mains specifications:
  • Voltage ETC-125 A :  Multivoltage 115VAC and 230VAC; 115V(90-132) and 230V(180-264)
  • Voltage ETC-400 A/R : 115V(90-127) or 230V(180-254)
  • Frequency ETC-125 A: 47 - 63 Hz
  • Frequency ETC-400 A/R : 45 - 65 Hz
  • Power consumption (max.) ETC-125 A: 75 VA
  • Power consumption (max.) ETC-400 A/R: 350 W
  • Instrument dimensions:
  • ETC-125 A, ETC-400 A and ETC-400 R
  • L × W × H: 172 × 72 × 182 mm / 6.8 × 2.8 × 7.2 in
  • Instrument weight:
  • ETC-125 A: 1.8 kg / 3.9 lb
  • ETC-400 A : 1.6 kg / 3.5 lb
  • ETC-400 R :  1.7 kg / 3.7 lb
  • Shipping (including shipping cargo box):
  • ETC-125 A: 3.0 kg / 6.6 lb
  • ETC-400 A: 2.8 kg / 6.2 lb
  • ETC-400 R : 4.5 kg / 9.9 lb
  • Size, L × W × H:
  • ETC-125 A / 400 A: 345 × 235 × 135 mm / 13.6 × 9.3 × 5.3 in
  • ETC-400 R : 425 x 320 x 165 mm / 16.7 x 12.5 x 6.5 in
  • Miscellaneous
  • Serial data interface :  RS232
  • Operating temperature: 0 to 40°C / 32 to 104°F
  • Storage temperature: -20 to 50oC / -4 to 122oF
  • Humidity:  0 to 90% RH
  • Protection class:  IP-10
  • DNV Marine Approval, Certificate no: A-10384

  • (1) JOFRA ETC dry-block calibrator
  • (1) Traceable calibration certificate - temperature performance
  • (1) JOFRACAL calibration software
  • (1) User and reference manual
  • (1) Mains power cable
  • (1) Shoulder strap
  • (1) RS232 cable
  • (1) Predrilled insertion tube (ETC-125 A only)
  • (1) Tool for insertion tubes (ETC-125 A only)
  • (1) Carrying case (ETC-400 R only) 1)
  • (1) JOFRA IR-LAB calibration software (ETC-400 R only)
  • (1) Emissivity table (ETC-400 R only)


Download

Note: Prices are not binding at any time subject to change without prior notice


  Options 0 Item Selected
Image
Model
Product Name
Price
Available
Quantity
Ametek Jofra ETC [ETC125AMULA01E] Dry Block Calibrator, -10 to 125°C, Multi voltage 115 and 230 VAC EU w/Holes Metric Insert 1 x 12.5mm, 1 x 6mm, 1 x 4mm, 1 x 8mm and NPL & NIST Traceable Calibration Certificates
ETC125AMULA01E
Rp.118.781.600
4 - 6 WEEKS
Ametek ETC-125A [ETC125AMULA01EC] Dry Block Calibrator, -10 to 125°C 230 VAC EU w/Holes Metric Insert 1 x 12.5mm, 1 x 6mm, 1 x 4mm, 1 x 8mm, NPL & NIST Traceable Calibration Certificates and Carrying Case
ETC125AMULA01EC
Rp.127.972.000
4 - 6 WEEKS
Ametek ETC-125A [ETC125AMULA01H] Dry Block Calibrator, -10 to 125°C 230 VAC EU w/Holes Metric Insert 1 x 12.5mm, 1 x 6mm, 1 x 4mm, 1 x 8mm and DANAK Accredited Calibration Certificate
ETC125AMULA01H
Rp.184.036.000
4 - 6 WEEKS
Ametek ETC-125A [ETC125AMULA01HC] Dry Block Calibrator, -10 to 125°C 230 VAC EU w/Holes Metric Insert 1 x 12.5mm, 1 x 6mm, 1 x 4mm, 1 x 8mm, DANAK Accredited Calibration Certificate and Carrying Case
ETC125AMULA01HC
Rp.193.226.400
4 - 6 WEEKS
Ametek ETC-125A [ETC125AMULA02E] Dry Block Calibrator -10 to 125°C 230 VAC EU w/Holes Imperial Insert 1 x 1/2", 1 x 3/8", 1 x 1/4", 1 x 5/32", NPL and NIST Traceable Calibration Certificates
ETC125AMULA02E
Rp.118.781.600
4 - 6 WEEKS
Ametek ETC-125A [ETC125AMULA02EC] Dry Block Calibrator, -10 to 125°C 230 VAC EU w/Holes Imperial Insert 1 x 1/2", 1 x 3/8", 1 x 1/4", 1 x 5/32", NPL and NIST Traceable Calibration Certificates & Carrying Case
ETC125AMULA02EC
Rp.127.972.000
4 - 6 WEEKS
Ametek ETC-125A [ETC125AMULA02H] Dry Block Calibrator, -10 to 125°C 230 VAC EU w/Holes Imperial Insert 1 x 1/2", 1 x 3/8", 1 x 1/4", 1 x 5/32" and DANAK Accredited Calibration Certificate
ETC125AMULA02H
Rp.184.036.000
4 - 6 WEEKS
Ametek ETC-125A [ETC125AMULA02HC] Dry Block Calibrator, -10 to 125°C 230 VAC EU w/Holes Imperial Insert 1 x 1/2", 1 x 3/8", 1 x 1/4", 1 x 5/32" and DANAK Accredited Calibration Certificate & Carrying Case
ETC125AMULA02HC
Rp.193.226.400
4 - 6 WEEKS
  Accessories 0 Item Selected