The Dwyer AVUL Series air velocity transmitter offers air velocity or volumetric flow of clean air and non-combustible, compatible gases. Simultaneous current and voltage outputs on AVUL models provide universal inputs to monitoring equipment while the output range, units, and 0 to 5/10 VDC output can be configured via local DIP switches. Zero and span adjustments can be made via digital push buttons.

Dwyer AVUL Series air velocity transmitters are available with a standard 5% accuracy or a 3% optional upgrade. The optional integral display on the AVUL series provides a convenient way to locally monitor process values and configure the unit. Additionally, optional BACnet MS/TP or Modbus® RTU/ASCII communication protocol allows units to be daisy-chained while providing access to all of the velocity and flow data, as well as additional information such as air temperature.

There are no reviews for this product.

Write a review

  • Clean air & non-combustible, compatible gases
  • Field-selectable ranges: 1000, 2000, 3000, 4000 FPM (5, 10, 15, 20 m/s)
  • Accuracy: ±(5% of reading + 0.2 m/s) standard; ±(3% of reading + 0.2 m/s) optional
  • 4 to 20 mA, 0 to 5 VDC, 0 to 10 VDC outputs
  • BACnet or Modbus communication optional
  • Digital push button zero & span adjustments
  • Optional 5-digit LCD

  • Service: Clean air and non-combustible, compatible gases.
  • Wetted Materials: Consult factory.
  • Range: 1000, 2000, 3000, 4000 FPM (5, 10, 15, 20 m/s); Field selectable.
  • Accuracy: ±(5% of reading + 0.2 m/s) or ±(3% of reading + 0.2 m/s) @ standard conditions, depending on model.
  • Temperature Limits: 32 to 122°F (0 to 50°C).
  • Power Requirements: 24 VDC ±20% or 24 VAC ±20%.
  • Humidity Limits: 5 to 95% RH, non-condensing.
  • Output Signals: 4 to 20 mA, 0 to 5 VDC, 0 to 10 VDC.
  • Response Time (90%): 10 s, typical.
  • Zero & Span Adjustments: Digital push buttons.
  • Output Load Resistance: Current output: 0 to 1100 Ω max.; Voltage output: Minimum load resistance 1 kΩ.
  • Current Consumption: 60 mA max.
  • Display (optional): 5 digit LCD.
  • Electrical Connections (Analog): Power and output: four wire removable European style terminal block for 16 to 26 AWG.
  • Communication (optional): Connections: BACnet MS/TP or Modbus® RTU/ASCII: three wire removable European style terminal block for 16 to 26 AWG; Supported
  • baud rates: 9600, 19200, 38400, 57600, 76800, 115200.
  • Device Load: 1/8th unit load.
  • Electrical Entry: 1/2˝ NPS thread. Accessory (A-151): Cable gland for 5 to 10 mm diameter cable.
  • Enclosure Rating: NEMA 4X (IP66).
  • Mounting Orientation: Flow direction must be parallel to the sensor tip.
  • Weight: 6.0 oz (160 g).
  • Agency Approval: BTL, CE.

  • (1) AVUL Air Velocity Transmitter
  • (1) Instruction Manual