• Vaisala HMT361 [HMT3601D22DCA1B3BA5A10] Intrinsically Safe Humidity and Temperature Transmitter w/ IECEx (VTT), Ex ia IIC T4 Certificate

Vaisala HMT361 [HMT3601D22DCA1B3BA5A10] Intrinsically Safe Humidity and Temperature Transmitter w/ IECEx (VTT), Ex ia IIC T4 Certificate

Not yet rated Write a review
Vaisala
Rp.71.500.000
Availability:
4 - 6 WEEKS
Product Code:
HMT3601D22DCA1B3BA5A10
Brand:
Vaisala
Update Terakhir:
13 May 2017
  • Free delivery

  • Money back guarantee

Share

HMT361 Intrinsically Safe (Ex ia) Humidity and Temperature Transmitter for Wall Mounting.
The HMT361 is the top-of-the-line wall-mounted intrinsically safe transmitter for hazardous areas. In addition to displaying humidity and temperature readings, the HMT361 calculates dew point, absolute humidity, wet bulb temperature, and mixing ratio. The Vaisala HUMICAP® Humidity and Temperature Transmitter HMT360 series incorporates Vaisala’s 30 years of experience in industrial humidity measurement.

The transmitter has a large display for convenient monitoring of the reading and transmitter setting changes. For example scaling can easily be changed by the user.

Analog outputs are preset at the factory to:

  • Channel 1: 4…20 mA = -40...+60°C (-40...+140°F) Td
  • Channel 2: 4...20 mA = -40...+60°C (-40...+140°F) T

Safe operation with the entire transmitter in hazardous areas: Div I and II (USA, Canada), Categories 1G/Zone 0 and 1D/Zone 20 with protection cover (EU).

In order to achieve a safe installation, each 4-20mA output requires an external intrinsically safe electrical surge barrier. Surge barriers should be located outside the hazardous area in a general purpose electronics enclosure. Each 4-20mA loop will require a separate barrier.

  • Dvision 1 and 2 (USA, Canada), categories 1G/Zone 0 and 1D / Zone 20 w/protection cover
  • HUMICAP Sensor
  • Temperature Range: -40 to 180°C (-40 to 356°F)
  • RH measurement: 0 to 100%
  • Operating voltage: 12 to 28V
  • 4 to 20mA output
  • Models:
    • HMT361 for wall mounting
    • HMT363 for duct mounting and tight spaces
    • HMT364 for high pressures up to 100 bar and vacuum conditions
    • HMT365 for high temperatures
    • HMT367 for high humidities
    • HMT368 for pressurized pipelines up to 40 bar

Specifications

  • (1) Calibration certificate (ISO9001 compliant, traceable)
  • (1) NPT1/2" conduit fitting included to facilitate wiring
  • (1) User's Guide in English

Download

Note: Prices are not binding at any time subject to change without prior notice