Techno-AC Success AG317G [AG-317G] Underground Pipe and Cable Locator with GPS Receiver
The set is designed for accurate location of underground utilities and their depth measurement (power/signal cable lines, armored fiber optic cables, pipes made of conductive materials), search for defects in cable lines, survey the ground before the excavation works in the shortest time and with great reliability and prevent damage to engineering utilities. The set includes a monoblock receiver with a large LCD screen, which indicates actual position of cable and pipe and automatically measures burial depth up to 10 m, as well as current rate. Built-in GPS/GLONASS module to store the coordinates of located utility. "Probe" mode for locating NON-METALLIC utilities with pipe sonde (optional). The set features the latest AG-107 autonomous transmitter with built-in batteries, LCD display, and built-in inductive antenna, for tracing utilities with a non-contact method. Transmitter output power up to 60 W.
Success AG-317G Applications:
Detection of cables and any metal pipelines underground up to 10 m.
Direct digital measurement of the depth up to 10 m.
Tracing of metal utilities at distance up to 5 km.
Detection of energized cables.
Detection of intersections of the pipeline and cable.
Detection of defects in cable lines.
Survey the ground before the excavation works
Storing of GPS\GLONASS coordinates and mapping of located utilities.
Location of non-metallic utilities with optional pipe sonde.
Automatic measurement of burial depth and current rate.
Built-in GPS/GLONASS module to store the coordinates of located utility.
"Probe" mode for locating NON-METALLIC utilities with pushing rod and pipe sonde (optional).
Several indication modes: "Route", "Graph", "Graph+", "MIN&MAX", "R.dis." (Relative distance to the utility) and "2 frequencies" which allow operator to utilize full potential of device.
Additional functions when connecting external sensors.
Vast range of supported frequencies (50(60) / 100 (120) / 512/ 1024/ 8192 / 32768 Hz, WideBand 40…8000 Hz, Radio 8…40 kHz).
Menu in English and Russian.
Connect Power Bank and work at sub-zero temperatures, Power Bank is hidden under the clothes of the operator.
AG-107 transmitter:
Built-in rechargeable battery.
Maximum output power up to 30 W in continuous and up to 60 W in intermittent mode.
Maximum output voltage up to 60 V.
Work from an external power supply of 10...25 V.
Alarm and protection against connection to a live load.
Several types of protection against several factors (exceeding the allowable external supply voltage (>27 V) and the voltage on the output clips).
Built-in "multimeter" indicates the operator's choice of voltage, current, resistance, output power or supply voltage.
Built-in transmitting antenna for non-contact pointing of the signal to utility.
Manual power reduction/increase after auto-adjustment.
Small size and weight.
AP-019.3 receiver:
Receiver Quasi resonant filter centre frequency: 50(60) / 100(120) / 512 / 1024 / 8192 / 32768 Hz
“Wide band” frequency band: 0,04...8 kHz
Frequency range "Radio": 8...40 kHz
Sonde frequency: 512 Hz
Dynamic range of incoming signal: 120 dB
Number of embedded sensors: 4
Max. sensitivity (in "Graph" mode: F0 = incoherent distortion +10 dB is 31…35 kHz): 5 mkA at 1m distance
Data log capacity: 2300 "points"
Connected external sensors: CI-105, HP-117, DODK-117, DKI-117 (made by "TECHNO-AC")
Sensitivity control: Auto-for 2D display "Route"; Semi-automatic or manual (optional) - for the "Graphic", "Graphic+", MIN&MAX and "Sonde"; Automatic or manual (optional) - for the "2F" mode
Determination the burial depth of the route: Automatically in "Route" mode 0...10 m; By pressing a button in "Sonde" mode
Burial depth identification accuracy: ±5%
Identification of the effective current in the route: Automatically in "Route" mode 0.001...49.99 A
Accuracy of current measurement of received signal: ±5%
Support of energy saving (intermittent) modes of the route locating transmitters: At combined work with the route locating transmitters made by "TECHNO-AC" ("Pulse" mode)
Visual indication: Graphic display LCD display, 320x240 pix., with LED backlight
Induced parameters: 2D visualization of the route location relative to the device; Graphics of the signal level from sensors; Route burial depth; Signal current; Signal strength; Settings and control parameters
"Modulation" modes (special form signal): Pulse "Pu" (short-term transmissions of the sine signals); Transmission duration 0,12 sec.; Transmissions repetition frequency 1 Hz. Dual-frequency "2F" (simultaneous frequency generation 1024 Hz, 8192 Hz); Amplitudes ratio 4/1 (respectively)
Output parameters under power supply voltage: 12…15V
Output current, А
Restricted by the program under manual increment, ≥: 5 - at frequency 512 Hz "0.5" / 1024 Hz "1.0" / 8192 Hz "8.2" / "2F". 3 - at frequency 32768 Hz "33"
Set by the program for automatic adjustment with the external load of "clips" or "clamp", ≥: 0,1
Maximum output voltage, V
Depending on "modulation", ≥: 48 - in the dual-frequency modulation mode "2F". 60 - in other modes
Maximum output power, W
Restricted by the program, ≥: 30 - In the continuous "Co" and pulse "Pu" modes at load resistance up to 120Ω; In dual - frequency mode "2F" at load resistance up to 77Ω. 60 - At pulse mode "Pu" at load resistance up to 60Ω
Power supply sources:
Operating range of the supply voltages: Minimally acceptable voltage - 10 V; Maximum allowed voltage for operation - 15 V
Accumulator: 8 LiFePO4 26700 3,2 V accumulators
Charger: Charges up to a voltage of 14.6 V with a current of up to 10 A; Oscillation simultaneously with charging
External power supply sources (optional): Voltage 10...15 V, power ≥ 80 W; For example, car batteries "12 V"
Operating time ("life cycle"): When operating from the built-in accumulator, 1.2 hours in the "Co" and "2F" at 30 W initital output power or 5 hours in "Pu" mode at original output power 60 W; With the external power supply is fully conditioned by this external energy source characteristics therefore under mains supply operating time is unlimited
Operational characteristics:
An automatic control over the output voltage during oscillation process: Proportional control over the output power depending on the "energy potential" of the power supply source
Automatic shutdowns of the device: At power supply voltage in the "stop" mode < 8 V; At power supply voltage > 15,5 V; In case of short circuit of the output during the adjustment process (actuation of the hardware safety system of the terminal amplifier); In case of non-compliance of the oscillation mode settings depending on whether the external antenna is installed in the output or not (the switch to the "stop" mode); In case of "long" (≈100 sec.) downtime in the "stop" mode (if the buttons are not pushed).
Adjustment with load: Automatic, up to the reaching of the specific consumption rate or attainment of the load current: ≥ 0,1 А. Manual (via buttons LESS / MORE "« »") after the automatic adjustment.
Connection options to the communication under examination: "Contact" connection with "earth return"; "Non-contact" connection with application of the internal transmitting antenna "In"; "Non-contact" connection with application of the external transmitting antenna "An" (signal intensity is higher and communication access is more convenient compared to the built-in transmitting antenna "In"); "Non-contact" connection using the transmitting induction "clamp" (selection of the cable from the bunch us possible)
Electromagnetic compatibility:
Classification in accordance with the Russian State Standard (GOST) 51318.22-2006: Class A
Structural parameters:
Power output amplifier: The technology - updated CLASS D; Efficiency to 85%
LED indicators: Separate light-emitting diodes indicating parameters and modes; Digital indicator displaying the modes and parameters values and also showing output parameters of the "MULTIMETER" measurements, e.g.: output voltage (V), load current (А), load power (W) and load resistance (Ω /kΩ)
Overall dimensions of the electronic unit (case), not more than, mm: 216х180х105
The weight of the electronic unit, not more than, kg: 2
Operating conditions:
The admissible environment temperatures range when in operation: -30…+60°С