Display
Hi-resolution (640×480 pixels) full digital true color TFT LCD with adjustable brightness, it is capable of providing high contrast viewing of the waveform from bright, direct sunlight to complete darkness.
The hi-resolution true color TFT LCD display with fast 60 Hz update gives an “analog look” to the waveform providing detailed information that is critical in many applications including nuclear power plant inspections.
Real Time Clock
The instrument clock keeps running tracking the time.
Communication
High Speed USB2.0 OTG port
High speed USB2.0 OTG interface support U disk mode and data connection mode. With USB cable connecting instrument and computer, it can realize data file transfer and work for USBHost mode to operate the external connecting U disk.
The DataPro software helps manage and format stored inspection data for high-speed transfer to the PC. Data can be printed or easily copied and pasted into word processing files and spreadsheets for further reporting needs. New features include live screen capture mode and database tracking.
Battery
Internal rechargeable Li-ion battery pack rated 7.2V at 8800 mAh
10 hours nominal operating time depending on display brightness
8-10 hours typical recharge time
Knob
Operating adjustments are easily and quickly made using the rotary knob.
Range
Up to 9999 mm in steel; range selectable in fixed steps or continuously variable, suitable for use on large work pieces and in high-resolution measurements.
Pulse
Pulse Energy selectable among 200V, 300V, 400V, 500V
Pulse Width tunable from 30ns to 510ns to match the probes with different frequency
Pulse Repetition Frequency adjustable from 10 Hz to 1 KHz in 1 Hz increments
Damping selectable among 200Ω and 500Ω for optimum probe performance
Test Modes including Straight, Angle, Dual and Thru-transmission.
Receiver
Sampling:10 digits AD Converter at the sampling speed of 400 MHz
Rectification:Positive Halfwave, Negative Halfwave, Fullwave and RF
Analog Bandwidth: 0.2MHz to 20MHz capability with selectable frequency ranges (automatically set by the instrument) to match probe for optimum performance.
Gain:0 dB to 110 dB adjustable in selectable steps 0.1 dB, 2 dB, 6 dB, and locked
Gates
Two fully independent gates offer a range of measurement options for signal height or distance using peak triggering.
The echo-to-echo mode allows accurate gate positioning for signals which are extremely close together.
Gate Start: Variable over entire displayed range
Gate Width: Variable from Gate Start to end of displayed range
Gate Height: Variable from 0 to 99% Full Screen Height
Alarms: Threshold positive/negative
Memory
Memory of 100 channel files to store calibration set-ups
Memory of 20000 wave files to store A-Scan patterns and instrument settings.
All the files can be stored, recalled and cleared.
Video Recorder
Screen scenes can be captured as movie files. More than 100 hours movie can be saved to the inside memory. They can be re-played using the instrument or the PC software delivered with the instrument.
Video Recorder is useful in many situations, convenient for those who want to analyze the probing activities later.