• Dwyer 681 Sanitary Pressure Transmitter

Dwyer 681 Sanitary Pressure Transmitter

Not yet rated Write a review
Dwyer Instruments

Available Options

Rp.47.722.600
Availability:
4 - 6 WEEKS
Product Code:
681
Brand:
Dwyer Instruments
Update Terakhir:
03 Jul 2023
  • Free delivery

  • Money back guarantee

Share

The Dwyer 681 sanitary pressure transmitter is compatible with liquids and gases and is designed to meet 3A standards for applications in food, dairy, beverage and pharmaceutical processing, liquid level control, and sanitary pipelines. The 681 is available in pressure ranges from 0 to 1 psi (50 psi over-pressure) up to 0 to 300 psi (1,000 psi over-pressure) and features a ±0.20% full-scale accuracy.

This Dwyer unit is fully sealed to withstand high pressure wash-down in Clean-in-Place (CIP) and Sterilize-in-Place (SIP) installations. Available as a 1-1/2 or 2 inch process connection, the 681 features a no liquid fill diaphragm with negligible clamping effect. A 1/2 inch conduit fitting, 15-foot (4.5m) shielded cable with vent tube and sealed screws for zero and span adjustment combine to make this Dwyer sanitary pressure transmitter completely watertight.

  • Pressure ranges from 0 to 1 psi up to 0 to 300 psi
  • 1-1/2 & 2 inch sanitary clamp fittings available
  • Meets 3A standards for multiple applications
  • Food, dairy, beverage & pharmaceutical processing, liquid level control & sanitary pipelines
  • Fully sealed to withstand Clean-in-Place (CIP) & Sterilize-in-Place (SIP) installations
  • Applications:
  • Sanitary process applications
  • Food and beverage processing
  • Water processing
  • Dairy processing
  • Pharmaceutical processing

            • Service: Compatible liquids and gases.
            • Wetted Parts: 316L SS.
            • Accuracy: ±.20% FS (includes
            • non-linearity, hysteresis and nonrepeatability).
            • Temperature Limits: -40 to 260°F (-40 to 125°C) 10 to 90% RH, noncondensing.
            • Pressure Limits: See table.
            • Compensated Temperature Range: 20 to 180°F (-7 to 80°C).
            • Thermal Effect: Zero and span shift: ±2.0% FS/100°F.
            • Power Requirements: 9 to 30 VDC.
            • Output Signal: 4 to 20 mA, 2-wire.
            • Zero and Span Adjustment: ±0.5 mA, non-interactive.
            • Response Time: ≤ 10 ms.
            • Loop Resistance: 800 Ω.
            • Electrical Connections: 1/2˝ conduit
            • fitting and strain relief with 15 ft (4.5 m) cable.
            • Process Connection: 2˝ or 1-1/2˝
            • sanitary clamp fitting male NPT.
            • Clamping Effect: Zero and span shift: ±0.15% FS for ranges up to 30 psi; ±0.25% FS for ranges >30 psi.
            • Weight: 8 oz (227 g)

            • (1) 681 Sanitary Pressure Transmitter
            • (1) Instruction Manual

            Download

            Note: Prices are not binding at any time subject to change without prior notice