• GF Signet 9950 [3-9950-1] Dual Channel Transmitter, 12 to 24 VDC

GF Signet 9950 [3-9950-1] Dual Channel Transmitter, 12 to 24 VDC

Not yet rated Write a review
GF Signet
Rp.36.950.000
Availability:
4 - 6 WEEKS
Product Code:
3-9950-1
Brand:
GF Signet
Update Terakhir:
13 May 2017
  • Free delivery

  • Money back guarantee

Share

The GF Signet 9950 Transmitter is a two channel controller that can support two sensors of same or different types in one instrument. The sensor types supported by the 9950 are Signet Flow, pH/ORP, Conductivity/Resistivity, Salinity, Temperature, Pressure, Level, Dissolved Oxygen, and devices that transmit a 4 to 20 mA signal with the use of the 8058 iGoR Signal Converter.
The 9950 includes advanced features such as derived functions, advanced multiple relay modes, and timer based relay functions. Derived functions allows for the control of a relay or current loop with the sum, delta (difference), or ratio of two measurements, for example delta pressure and delta temperature. Multiple relay modes allow up to three signals to be used for the control of a single relay. This can be any combination of analog and binary inputs. The timer relay modes allow relay to be activated on a repeating basis from every minute to once every 30 days. Weekday timer mode allows a relay to be turned on for specific days and times.

The GF Signet 9950 Transmitter is compatible with 3-9950.393 relay modules providing the ability to interface up to four binary inputs. The binary inputs are compatible with either open collector or mechanical contacts. The binary inputs can supply power to the four inputs or accepts powered outputs from external devices. These inputs can be used with level switches, flow switches, pressure switches or other devices. The inputs can be used to directly control the relays of the 9950 or can be used in combination with the measurement readings for advanced control of your process.
Applications for the GF Signet 9950 Transmitter include:
  • Wastewater treatment
  • Reverse osmosis
  • Deionization
  • Chemical manufacturing / addition
  • Metal and plastic finishing
  • Fume scrubber
  • Cooling tower
  • Media filtration
  • Chemical dosing/ injection
  • Aquatic life support
  • Pools & fountains
  • Rinse tanks
  • Chemical neutralization

  • Part Number: 3-9950-1
  • Power Supply: 12 to 24 VDC
  • One instrument for multiple sensor types
  • Two diff erent sensor types can be combined in one unit
  • Configurable display
  • Derived measurements
  • Advanced boolean logic
  • Optional modules can be added for additionalcapabilities
  • USB Port for Field Upgrades using standard
  • USB Flash Drive

  • General:
  • Input Channels: Two frequency or S3L inputs
  • Enclosure and Display:
  • Case Material: PBT
  • Window: Shatter-resistant glass
  • Keypad:4 buttons, injection-molded silicone rubber seal
  • Display: Dot matrix, LCD
  • Indicators: Two horizontal digital bar graphs, four LED relay status indicators
  • Update Rate: 1 s
  • LCD: Contrast 5 settings
  • Size: ¼ DIN
  • Mounting:
  • Panel: ¼ DIN, ribbed on four sides for panel mounting clip inside panel, silicon gasket included
  • Wall: Large enclosure (sold as an accessory
  • Terminal Blocks:
  • Pluggable Screw Type: Use minimum 105 °C rated wire
  • Torque Ratings:
  • Power/Loop: 0.49 Nm (4.4 lb-in.)
  • Freq/S3L: 0.49 Nm (4.4 lb-in.)
  • Relay Module: 0.49 Nm (4.4 lb-in.)
  • Connector Wire Gauge:
  • Power, Loop: 12 to 28 AWG
  • Freq/S3L: 16 to 28 AWG
  • Relay Module Connector Wire Gauge:
  • Relay 12 to 28 AWG
  • Ambient Operating Temperature:
  • DC Power: -10 °C to 70 °C (14 °F to 158 °F)
  • AC Power: -10 °C to 60 °C (14 °F to 140 °F)
  • Storage Temp -15 °C to 70 °C 5 °F to 158 °F
  • Relative Humidity: 0 to 100% condensing for (front only); 0 to 95% non-condensing (rear panel)
  • Maximum Altitude: 4,000 m (13,123 ft)
  • Enclosure Rating; NEMA 4X/IP65 (front face only)
  • Performance Specifications:
  • System Accuracy: Primarily dependent upon the sensor
  • System Response: Primarily dependent upon the sensor. Controller adds a maximum of 150 ms processing delay to the sensor electronics. Minimum update period is 100 ms. System response is tempered by the display rate, output averaging and sensitivity feature
  • Electrical Requirements:
  • Power to Sensors: Voltage +4.9 to 5.5 VDC @ 25 °C, regulated; Current 30 mA Maximum
  • Short Circuit: Protected
  • Isolation: Low voltage (< 48 V AC/DC)
  • Power Requirements:
  • DC (3-9950-1, 3-9950-2): 24 VDC nominal (10.8 to 35.2 VDC regulated)
  • AC (3-9950-2): 100 to 240 VAC, 50 to 60 Hz, 24 VA
  • Maximum current: 200 mA (without optional relay module)*; 500 mA (with optional relay module)*
  • *The current draw of the other modules and the sensors are minimal
  • Current Loop: 10.8 to 35.2 VDC 4 to 20 mA (30 mA max.)
  • Overvoltage protection: 48 Volt Transient Protection Device (for DC ONLY)
  • Current limiting for circuit protection
  • Reverse-Voltage protection
  • Input Types:
  • Digital (S3L) or AC frequency
  • 4 to 20 mA input via the 8058
  • Open collector
  • pH/ORP input via the Digital (S3L) output from the 2750 pH/ORP Sensor Electronics
  • Conductivity/Resistivity via the Digital (S3L) output from the 2850 Conductivity/Resistivity Sensor Electronics
  • Sensor Types: Flow, pH/ORP, Conductivity/Resistivity, Pressure, Temperature, Level/Volume, Salinity, Dissolved Oxygen, Other (4 to 20 mA)
  • Sensor Input Specifications:
  • Digital (S3L): Serial ASCII, TTL level, 9600 bps
  • Frequency Flow Sensors: 0.5 to 1500 Hz
  • Sensitivity(for coil type sensors): 80 mV @ 5 Hz, gradually increasing with frequency to 2.5 V
  • Freq. Range (for square wave type sensors): 0.5 Hz to 1500 Hz @ TTL level input or open collector
  • K-Factor Range: 0.0001 to 9999999
  • Accuracy: ± 0.5% of reading max error @ 25 °C
  • Resolution: 1 µs
  • Repeatability: ± 0.2% of reading
  • Power Supply:
  • Rejection: No Effect ± 1 µA per volt
  • Short Circuit: Protected
  • Reverse Polarity: Protected
  • Update Rate: (1/frequency) + 100 ms

  • (1) GF Signet 9900 [3-9950-1] Dual Channel Transmitter, 12 to 24 VDC
  • (1) Instruction manual

Download

Note: Prices are not binding at any time subject to change without prior notice