The Dwyer 641RM Air Velocity Transmitter features the same highly accurate heated mass flow sensor as the Series 641, with a remote probe construction. The units 6´ cable which connects the sensing probe with the electronic enclosure allows the enclosure to be mounted where it can be more easily accessed.

Applications for the 641RM include:
  • Exhaust stack flow monitoring
  • Air control in drying processes
  • HVAC air velocity measurements
  • Fan supply and exhaust tracking
  • Clean room ventilation monitoring

  • Part Number: 641RM-12
  • LED Display: Without
  • Ranges from 250 FPM (1.25 MPS) to 15,000 FPM (75 MPS)
  • LED display option
  • Easy push button set-up
  • Compact housing
  • 4 to 20 mA output
  • Digital filter for signal damping

  • Service: Clean air and compatible, noncombustible gases.
  • Accuracy: 3% FS process gas: 32 to 122°F (0 to 50°C); 4% FS process gas: -40 to 32°F & 122 to 212°F (-40 to 0°C & 50 to 100°C).
  • Response Time: Flow: 1.5 s to 95% of final value (output filter set to minimum).
  • Temperature Limits: Process: -40 to 212°F (-40 to 100°C); Ambient: 32 to 140°F (0 to 60°C).
  • Pressure Limit: 100 psi (6.89 bar) maximum.
  • Humidity Limit: Non-condensing.
  • Power Requirements: 12 to 35 VDC, 10 to 16 VAC. 1.5 A rating required on supply due to initial power surge drawn by transmitter.
  • Output Signal: 4 to 20 mA, isolated 24V source, 3 or 4-wire connection.
  • Output Filter: Selectable 0.5–15 (seconds).
  • Loop Resistance: 600 Ω max.
  • Current Consumption: 300 mA max.
  • Electrical Connections: Screw terminal.
  • Mounting Orientation: Unit not position
  • sensitive. Probe must be aligned with airflow.
  • Weight: 13.2 oz (374.26 g).
  • Cable Length: 6´ (1.82 m).
  • Probe Length: 12˝ (30.48 cm) standard.
  • Probe Diameter: 5/16˝ (0.79 cm).
  • OPTIONAL DISPLAY VERSION: Display: 4-1/2 digit 1/2˝ red LED.; Resolution: 1 FPM, 0.01 MPS (10 FPM @ 10,000 and 15,000 FPM ranges).; Weight: 13.9 oz (394.16 g).

  • (1) Instruction manual

Download