Delta Ohm HD32.8.8 Thermocouples Temperature Data Logger - 8 Inputs

Not yet rated Write a review
Delta Ohm
Rp.37,907,680
Availability:
4 - 6 WEEKS
Product Code:
HD32.8.8
Brand:
Delta Ohm
Update Terakhir:
22 Aug 2023
  • Free delivery

  • Money back guarantee

Share

8 or 16 INPUTS DATA LOGGER FOR THERMOCOUPLES
The HD32.8.8 and HD32.8.16 are two robusts data loggers with 8 inputs (HD32.8.8) or 16 inputs (HD32.8.16) for K, J, T, N, R, S, B and E type thermocouple with miniature connector temperature probes. During the measuring phase, the connected probes must be of the same type. The captured data can be displayed and processed on the PC using the DeltaLog9 software. The instrument has a total capacity of 800,000 acquisitions to be divided among all the present inputs. Storage can be managed in two ways: when the available memory is full, data are overwritten by starting from the oldest ones (circular memory), otherwise storage stops when the available memory is full. Maximum, minimum or average of the stored values are calculated.

HD32.8.16. 16 input datalogger instrument for temperature probes with K, J, T, N, R, S, B and E type thermocouple. Storage interval selectable between: 1, 5, 15, 30 s - 1, 2, 5, 10, 15, 30 min or 1 hour. Memory capacity 800,000 samples, to be divided among the channels having probes connected. Functions: CLOCK, RELATIVE, MINIMUM, MAXIMUM, MEAN MEASUREMENT. Simultaneous display of four inputs at a time. RS232C and USB1.1-2.0 serial interface. The instrument firmware can be updated by PC. Power supply: four 1.5V batteries type C, 12Vdc socket for mains voltage or PC USB port power supply.
The KIT includes: instrument HD32.8.16, four 1.5 V alkaline batteries type C, instruction manual and support/transport strap. The probes, tripod, carrying case and cables have to be ordered separately. Includes DeltaLog9 software downloadable from Delta OHM website.

  • 8-channel data logger
  • For thermocouples of type J, K, T, N, R, S, B, E
  • Display of 4 measurement data at the same time
  • 800,000 measurement data can be stored.
  • MIN/MAX/REL/MEAN/REL
  • Time

            • Number of inputs 8 for HD32.8.8; 16 for HD32.8.16
            • Measuring range and accuracy of the instrument Accuracy is referred to the instrument only, error due to the thermocouple or the cold junction reference sensor is not included
            • Thermocouple K: -200...+1370°C; ±0.1°C up to 600°C / ±0.2°C over 600°C
            • Thermocouple J: -100...+750°C; ±0.1°C up to 400°C / ±0.2°C over 400°C
            • Thermocouple T: -200...+400°C; ±0.1°C
            • Thermocouple N: -200...+1300°C; ±0.1°C up to 600°C / ±0.2°C over 600°C
            • Thermocouple R:  +200...+1480°C; ±0.3°C
            • Thermocouple S: +200...+1480°C; ±0.3°C
            • Thermocouple B: +200...+1800°C; ±0.4°C
            • Thermocouple E:  -200...+750°C; ±0.1°C up to 300°C / ±0.2°C over 300°C
            • Resolution: 0.05°C (in the range ±199.99°C); 0.1°C in the remaing range
            • Drift in temperature @20°C: 0.02% / °C
            • Drift after 1 year: 0.1°C / year
            • Internal watch accuracy: 1min/month max drift
            • Unit of measurement: °C - °F - K configurable
            • Memory capacity: up to 800,000 acqusitions to be divided among all the present inputs max 64 logging session (e.g. 1 probe connected = 800,000 acquistions, 8 probes connected = 96,000 acquisitions each probe)
            • Data Logging: Istantaneous or delayed, with the possibility of selecting the storage start and end time.
            • Storage interval can be selected among: 2,5,10,15,30 s; 1,2,5,10,15,20,30 min.; 1 hour
            • Data download: RS232C from 1200 to 38,400 baud, galvanically isolated. Sub D 9-pole male connector. USB 1.1 - 2.0 galvanically isolated.
            • Security of stored data: Unlimited
            • Power Supply: 4 per 1.5V alkaline batteries type C-BABY; External 12Vdc-1A power supply. Connector, external Ø 5.5mm, internal Ø 2.1mm. Power supply via the PC USB port.
            • Current consumption @6Vdc:
            • <60μA when the instrumen is off;
            • <60μA in sleep mode with all probes  connected
            • <40mA during data logging with all probes connected
            • Voltage insulation: 60 V between inputs; 500V between inputs and power supply
            • Autonomy: 200 hours with 7800mAh alkaline batteries and all probes connected
            • Connection: Miniature female socket for thermocouple
            • Operating conditions:
            • Operating Temperature -5...50°C
            • Storage temperature : -25 … 65°C
            • Working relative humidity: 0 … 90%RH, no condensation
            • Protection degree: IP64
            • General characteristics:
            • Dimensions (Length x Width x Height): 220x180x50mm
            • Weight: 1100 g (complete with batteries)
            • Materials: ABS, polycarbonate and aluminium
            • Display: Backlit graphic LCD 128x64 pixel
            • Keyboard: 15 keys, configurable also without PC. Security password for keyboard locking

            • (1) HD32.8.8 data logger,
            • (4) 1.5Vdc alkaline C-Baby type batteries
            • (1) Instruction manual
            • (1) Software Deltalog9 downloadable from Delta OHM website
            • (1) Support/transport strap
            • NOTE:  Probes, tripod, carrying case and cables have to be ordered separately.

            Note: Prices are not binding at any time subject to change without prior notice