Delta Ohm HD2128 [HD2128.1] 2-Input Thermocouple Thermometer

Not yet rated Write a review
Delta Ohm
Rp.10.174.240
Availability:
2 - 4 WEEKS
Product Code:
HD2128.1
Brand:
Delta Ohm
Update Terakhir:
19 Aug 2023
  • Free delivery

  • Money back guarantee

Tanyakan Pada Ahlinya

Pakar Teknologi Kami Siap Membantu!

(62) 021-53167044 | 0812-83861970 | 0812-9915277

Email Us

Share

The HD2108.1 and HD2108.2 with one input and the HD2128.1 and HD2128.2 with two inputs are portable instruments with a large LCD display. They measure the temperature using immersion, penetration or air contact probes. The sensor may be a thermocouple of type K, J, T, N, R, S, B or E. The HD2108.2 and HD2128.2 instruments are dataloggers. The HD2108.2 memorizes up to 76,000 samples, the HD2128.2 up to 38,000 pairs of values. These data can be transferred from the instrument connected to a PC via the RS232C serial port or USB 2.0 port. The logging interval, printing, and baud rate can be configured using the menu. All the models are fitted with an RS232C serial port and can transfer the acquired measurements in real time to a PC or to a portable printer. The Max, Min and Avg function calculate the maximum, minimum or average values. Other functions include: the relative measurement REL, the HOLD function, and the automatic turning off that can also be disabled. The HD2128.1 and HD2128.2 calculate the A-B difference of the temperatures captured by the two input channels.

The instruments have IP66 protection degree.

  • Part Number: HD2128.1
  • Data logger: Not included
  • TC input: 2 (Two)
  • Storage capacity: Not Available
  • PC interface: RS232C
  • A-B function: Included
  • Unit of measurement ° C - ° F - ° K - mV -mV * C
  • Type K, J, T, N, R, S, E thermocouple
  • With datalogger function
  • Autonomy of 200 hours with 1800 mAh alkaline batteries
  • Power supply 4 1.5V AA batteries
  • Degree of protection IP66

  • Measurement of temperature by instrument:
  • TC measuring range: K -200…+1370°C
  • TC measuring range: J -100…+750°C
  • TC measuring range: T -200…+400°C
  • TC measuring range: N -200…+1300°C
  • TC measuring range: R +200…+1480°C
  • TC measuring range: S +200…+1480°C
  • TC measuring range: B +200…+1800°C
  • TC measuring range: E -200…+750°C
  • Resolution: 0.05°C in the range ±199.95°C0.1°C in the remaing range
  • Instrument accuracy: Accuracy is referred to the instrument only; error due to the thermocoupleor to the cold junction reference sensor is not included.
  • Thermocouple K: ±0.1°C up to 600°C; ±0.2°C over 600°C
  • Thermocouple J:  ±0.05°C up to 400°C; ±0.1°C over 400°C
  • Thermocouple T: ±0.1°C; Thermocouple N ±0.1°C up to 600°C; ±0.2°C over 600°C
  • Thermocouple R:  ±0.25°C
  • Thermocouple S: ±0.3°C
  • Thermocouple B:  ±0.35°C
  • Thermocouple E: ±0.1°C up to 300°C; ±0.15°C over 300°C
  • Temperature drift @20°C: 0.02%/°C
  • Drift after 1 year: 0.1°C/year
  • Unit of measurement: °C - °F - K - mV - mV*C
  • Measured values storage:
  • Model HD2108.2: 2000 pages each one containing 38 samples, 76000 samples in total
  • Model HD2128.2: 2000 pages each one containing 19 samples, 38000 samples in total
  • Storage interval can be selected among: 1,5,10,15,30 s; 1,2,5,10,15,20,30 min.; 1 hour
  • Security of stored data; Unlimited, independent of battery charge conditions
  • Power Supply:
  • Batteries: 4 Batteries 1.5V type AA
  • Autonomy: 200 hours with 1800mAh alkaline batteries
  • Current consumption with instrument off: 20μA
  • Main: 12Vdc / 1000mA Output main adapter
  • Serial interface RS232C:
  • Type: RS232C galvanically isolated
  • Baud rate: can be set from 1200 to 38400 baud
  • Data bit: 8
  • Parity: None
  • Stop bit: 1
  • Flow Control: Xon/Xoff
  • Serial cable lenght: Max 15m
  • Print interval: Immediate or selectable among: 1,5,10,15,30 s; 1,2,5,10,15,20,30 min.; 1 hour
  • USB interface model HD2108.2 and HD2128.2:
  • Type: 1.1 - 2.0 galvanically isolated
  • Connections: 
  • Probes input:  2-pole female polarized standard miniatur connector
  • Serial interface: 8-pole MiniDin connector
  • USB interface: Type B Mini USB connector
  • Mains adapter: 2-pole connector (positive at centre)
  • Operating conditions:
  • Operating Temperature: -5...50°C
  • Storage temperature: -25 … 65°C
  • Working relative humidity: 0 … 90%RH, no condensation
  • Protection degree: IP66
  • General characteristics:
  • Dimensions (Length x Width x Height): 185x90x40mm
  • Weight: 470g (complete with batteries)
  • Materials: ABS, rubber
  • Display: 2 rows 4½ digits plus symbols
  • Visible area: 52x42mm
  • Time:
  • Date and time in real time
  • Accuracy 1min/month max drift

  • (1) HD2128.1,
  • (4) 1.5V alkaline batteries
  • (1) Instruction manual
  • (1) Case
  • (1) Deltalog9 software downloadable from Delta OHM website.
  • NOTE: Probes and cables have to be ordered separately.

Note: Prices are not binding at any time subject to change without prior notice