• AquaMetrix AM-2252 Dual Input Controller

AquaMetrix AM-2252 Dual Input Controller

Not yet rated Write a review
AquaMetrix
Rp.47.769.000
Availability:
3 - 4 WEEKS
Product Code:
AM-2252
Brand:
AquaMetrix
Update Terakhir:
13 May 2017
  • Free delivery

  • Money back guarantee

Ask an Expert

Our tech experts are ready to help!

(62) 021-53167044 | 0812-83861970 | 0812-9915277

Email Us

Share

The Aquametrix AM-2252 Dual Input Controller monitors and controls up to 2 parameters simultaneously. pH, ORP, Conductivity, and flow are supported and two new input options have been added; ISE and 4-20mA support. The AM-2252 provides control of external devices using its five independent control and alarm relays. Each relay has adjustable high, low, and in range set-points, cycle timer with adjustable on and off times. This feature enables tighter control of batch processes by eliminating chemical overshoot. All relays can be activated by temperature or flow totalizer reading as well. The fifth relay can be common for multiple parameters.

There are no reviews for this product.

Write a review

  • pH, ORP, conductivity & ISE parameters
  • Parameter available in both channels
  • channel 2 accepts a 4-20mA sensor
  • Multi-point calibration for conductivity and ISE
  • 1 point calibration for pH
  • Five control/alarm relays
  • Temperature or flow totalizer output

  • Probe Parameters:
  • Sensor:
  • pH/ORP/ISE: 6-Wire Differential or Combination
  • Conductivity: 4-Wire contacting : Any cell constant between 0.01 and 100
  • 4-20mA: Current sinking Current source
  • Flow: Pulse output: Paddle-wheel, Magmeter
  • Temperature Elements:
  • pH/ORP/ISE: 100, 1000 Ω RTD 300, 3000 Ω NTC or none
  • Conductivity: 100, 1000 Ω RTD 300, 3000 Ω NTC
  • 4-20mA: N/A
  • Flow: Pulse output: N/A
  • Available Inputs:
  • pH/ORP/ISE: 1 and 2
  • Conductivity: 1 and 2
  • 4-20mA: 1 and 2
  • Flow: Pulse output: Only 1
  • Measurement Range (Process): 
  • pH/ORP/ISE: pH 0 to 14 pH ORP -2000 to +2000 ISE 0-1000 ppm
  • Conductivity: pH 0 to 14 pH ORP -2000 to +2000 ISE 0-1000 ppm
  • 4-20mA: -9999 to +9999
  • Flow: 0 to 999 in any units
  • Measurement Range (Temperature):
  • pH/ORP/ISE: -20 to 120 °C
  • Conductivity: -20 to 120 °C
  • 4-20mA: -N/A
  • Flow: Flow Totalizer 0 to 999 in any units
  • Temperature Compensation: 
  • pH/ORP/ISE: Automatic or none
  • Conductivity: Automatic or Manual -20 to 120 °C
  • 4-20mA: Sensor specific
  • Flow: Display Flow Totalizer
  • Outputs:
  • Analog:
  • Three 4-20 mA outputs
  • Optically isolated. (Max Load - 800 Ω)
  • Scalable 4-20mA with PID (Process or Temperature)
  • Relays:
  • 2 SPDT
  • 8A @ 120 VAC or 30 VDC (resistive)
  • 4A @ 120 VAC or 30 VDC (inductive)
  • 2 SPST
  • 5A @ 250 VAC or 30 VDC (resistive load)
  • 2A @ 250 VAC or 30 VDC (inductive load)
  • Relay Modes:
  •  Rising/Falling/In Range.
  • Options: Relay Delay, Cycle, Overfeed Timer, Override
  • All relays can be triggered by process temperature or flow totalizer
  • Ratings:
  • Ingress Protection: NEMA 4X
  • Electrical: UL (US and Canada) and CE
  • Max. Power Input: 0.3 A @ 115 VAC or 20 W
  • Temperature: -20 to 70 °C
  • Humidity: 0 to 90% Relative Humidity, non-condensing
  • Physical: 
  • Mounting: Wall mount, panel mount with kit provided. pipe mount with optional kit
  • Dimensions: Front cover: 5.5”x5.5” (14 cm x 14 cm). Depth: 5” (13 cm)
  • Power: 120/240 VAC, 50 or 60 Hz
  • Weight: 2 lbs
  • Protection: NEMA 4X
  • Panel Cut-out:  5.4” x 5.4” (138 x 138 mm) full DIN

  • (1) Main Menu
  • (1) Instruction Manual

Download

Note: Prices are not binding at any time subject to change without prior notice