• AND Apollo GF10002A [GF-10002A] Precision Balance, 10,200g x 0.01g - 165mm x 165mm with External Calibration

AND Apollo GF10002A [GF-10002A] Precision Balance, 10,200g x 0.01g - 165mm x 165mm with External Calibration

Not yet rated Write a review
AND
Rp.61.155.400
Availability:
4 - 6 WEEKS
Product Code:
GF-10002A
Brand:
AND
Update Terakhir:
13 May 2017
  • Free delivery

  • Money back guarantee

Ask an Expert

Our tech experts are ready to help!

(62) 021-53167044 | 0812-83861970 | 0812-9915277

Email Us

Share

The AND Weighing Apollo GF-10002A Precision Balance, 10200g x 0.01g is robust and durable. The GF10002A features Compact Super Hybrid Sensor(C-SHS) that makes the scale compact, fast, and precise. The GF10002A includes a wide range of modes to meet workflow needs.

There are no reviews for this product.

Write a review

  • Capacity: 10,200 g
  • Readability: 0.01 g
  • Repeatability (std dev): 0.01g
  • Linearity:±0.03 g
  • Pan Size: 6.5 x 6.5" (165 x 165mm)
  • Impact shock detection (ISD) providing feedback to prevent damage to the weight sensor*1
  • Electronically controlled load (ECL) that enables precision management without using an external weight*1
  • Flow rate display (FRD) that makes calculating and recording flow rates easier and more accurate*2
  • Smart super hybrid sensor (Smart SHS) that realizes fast stabilization, long-term durability and low cost of ownership
  • Shock logging function that records up to 50 adverse impact loads with a timestamp for later inspection
  • Cushioning under the weighing pan to mitigate impact shocks significantly
  • Protection against vertical and transverse static overloading
  • Flow rate comparator that indicates whether the flow rate is within the designated limits
  • Tare memory function that saves the tare value in non-volatile memory
  • Built-in fanless ionizer with Quick Ion technology and external IR switch (GX-AE)
  • Large and detachable, antistatic glass breeze break (0.0001 g readability models)
  • Retractable doors that disappear into the back, requiring no extra space at the rear
  • Automatic self calibration in response to temperature changes or according to set schedules (GX-AE/A)
  • Automatic minimum weight calculation with either ECL or an actual, external weight
  • Alert function to ensure that the measured quantity is not smaller than the set minimum weight
  • Selectable response characteristics for trading weighing speed for higher display stability or vice versa
  • Large, front-mounted spirit level with LED illumination
  • Easy-to-adjust leveling feet with thumbwheels
  • User access control (UAC) that password-protects the balance from misusage
  • GLP/GMP/GCP/ISO compliant output to meet documentation requirements
  • Universal Flexi Coms (UFC) to customize printout content and layout*3
  • Gross/Net/Tare output
  • Data memory function to save weighing results, calibration results and unit masses to be used in counting mode in the device itself
  • Counting mode with the Automatic Counting Accuracy Improvement (ACAI) function
  • Percent mode function for target weighing or checking sample variation
  • Animal weighing (average & hold) function for weighing moving objects
  • Statistical calculation function (SCF) to facilitate the analysis of measurements
  • Five-level comparator function with buzzer
  • Auto power ON and OFF functions
  • Density determination function (optional density determination kits available for the 0.0001/0.001 g readability models)
  • Underhook for weighing a magnetic material as well as measuring density

  • Capacity: 10,200 g
  • Readability: 0.01 g
  • Pan Size: 6.5 x 6.5" (165 x 165mm)
  • Repeatability (std dev): 0.02 g (for 10000 g) 0.01 g (for 5000 g)
  • Linearity: ±0.03 g
  • Accuracy immed.following cal: ± 0.15 g (for 5000 g)
  • Stabilization time: Approx 1.5 sec (approx 0.8 sec for 50 g)
  • Sensitivity drift: ±2 ppm / °C (10 °C to 30 °C / 50 °F to 86 °F, when automatic self-calibration is OFF)
  • Calibration wt: 500g, 1000g, (1000g interval) 10000g
  • Display: Reverse Backlit LCD (Character height: 17.8 mm)
  • Display refresh rate: 5 times / second, 10 times / second or 20 times / second
  • Units: g (gram), oz (ounces), lb (pound), lb-oz (pound-ounce), ozt (troy ounce), ct (metric carat), mom (momme), dwt (pennyweight), gr (grain), pcs (counting mode), % (percent mode), SG (specific gravity), and a user-programmable unit.
  • Counting mode, min unit mass: 0.01g
  • Counting mode, # of samples: 5, 10, 25, 50 or 100 pieces
  • Percent mode, min 100% ref mass: 1.00g
  • Percent mode, min 100% display: 0.01%, 0.1% or 1% (depends on the reference mass stored)
  • Operating environ ment: 5 °C to 40 °C / 41 °F to 104 °F, 85% R.H. or less (no condensation)
  • Power supply / consumption: AC adapter / approx. 30 VA
  • Communication interface: RS-232C and USB
  • Overall Dimensions (WxDxH): 212 (W) x 317 (D) x 93 (H) mm / 8.3 (W) x 12.5 (D) x 3.7 (H) in
  • Net weight: Approx. 5 kg / 11 lb
  • Shipping Weight: 14.3 lbs / 13 x 17 x 11 inches

  • (1) GF-A Precision Balance
  • (1) AC Adapter
  • (1) USB Cable

Download

Note: Prices are not binding at any time subject to change without prior notice