  • ACR Systems SmartReader Plus 4 [01-0117] Four-Channel Pressure, Temperature and Relative Humidity Data Logger, 0-30 PSI Gauge With 128 KB Memory, -40°C to 70°C (-40°F to 158°F)

ACR Systems SmartReader Plus 4 [01-0117] Four-Channel Pressure, Temperature and Relative Humidity Data Logger, 0-30 PSI Gauge With 128 KB Memory, -40°C to 70°C (-40°F to 158°F)

Not yet rated Write a review
ACR Systems Inc.
Rp.38.960.800
Availability:
4 - 6 WEEKS
Product Code:
01-0117
Brand:
ACR Systems Inc.
Update Terakhir:
23 Nov 2023
  • Free delivery

  • Money back guarantee

Share

The ACR Systems SmartReader Plus 4 [01-0117] 4-Channel (0-30 PSI Gauge Pressure, Temperature, External RH, and External Temperature) Data Logger with 128 KB Memory provides easy monitoring and troubleshooting of pneumatic control systems. The unit is completely self-contained with a 1/4 in. quick-release pressure fitting to allow a fast and trouble-free connection. As an added bonus, the SmartReader Plus 4 also monitors ambient temperature and either external temperature (with thermistor probes) or temperature and relative humidity (RH) together (with an RH/temperature probe). Probes and sensors are sold separately. APPLICATIONS: Performance tracking of pneumatically controlled valves; verifying thermostat and humidistats; monitoring sensitive shipments, etc.

TrendReader 2 Software
The ACR Systems TrendReader 2 Software is a powerful, versatile and easy-to-use application, designed exclusively for ACR's SmartReader Plus, SmartReader, IAQ, OWL, TRH, JR and Nautilus data loggers. Powerful features and easy setup enables collected data to be thoroughly analyzed in seconds.

Downloading and Communicating with Data Logger
Setup, download and view information from a single data logger with ACR's IC-102 interface cable (included in software interface package). Connection is simple; plug the interface cable into the USB port of your computer and connect the other end to the logger. No tools, cards or docking stations are required.

Data Logger Setup
With built-in menus for sample rate and mode, start delay, equations and more, logger setup is fast and easy. In addition, equations are already included for all ACR sensors so you need only select the appropriate equation from the menu or customize your own. Real-time readings are displayed in the Setup window, allowing you to verify that your data logger is working correctly before placing it in the field.

Viewing Data
With TrendReader 2, data can be viewed in several ways. For presentation purposes, view your collected data in graphical format or for a more detailed analysis, view your data in table format. Either way, multiple channels of data can be displayed at once. Multiple graphs can be displayed together and compounded to create new graphs. For added presentation power, add comments, change graph colors, zoom in on specific portions of data, and display your data using custom engineering units. Print or copy and paste graphs into your reports and presentations. Select all, or portions of the table and copy and paste into your favorite Windows program.

Exporting Data
Use the export function in TrendReader 2 to export your data to other programs for further analysis. Data can be exported in TXT, BMP, PDF, JPG or CSV formats. Powerful features and easy setup enables collected data to be thoroughly analyzed in seconds.

  • Part Number: 01-0117
  • Temperature Range: -40°C to 70°C (-40°F to 158°F)
  • Pressure range: 0-30 PSI Gauge Pressure
  • Memory Size: 128 KB (capable of storing up to 87,000 readings)
  • Measure and Record Pressure and Temperature and (2) Optional Inputs for Temp and RH
  • Self-Contained with 1/4" Quick-Release Pressure Fitting Connection
  • (7) Pressure Ranges Available with ±0.5% of Full Scale @ 25°C
  • 25/second to 8 Hour User-Selectable Sampling Rate
  • Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery
  • Continuous (FIFO) or Stop When Full Sampling Methods
  • Note: SmartReader Data Loggers require TrendReader 2 Software to operate
  • Note: Probes, transformers and transducers not included

                                                                                                  • Size: 107mm x 74mm x 22mm (4.2” x 2.9” x 0.9”)
                                                                                                  • Weight: 110 g (3.75 oz)
                                                                                                  • Case Material: Noryl® Plastic
                                                                                                  • Battery: 3.6 volt Lithium
                                                                                                  • Resolution: 12-bit (1 part in 4096)
                                                                                                  • Mounting: Magnetic backing or locking eyelet
                                                                                                  • Clock Accuracy: ± 2 seconds per day
                                                                                                  • Sampling Methods: Continuous (First-in First-out)*, Stop When Full (Fill-then-stop). *Not available with sample rates faster than eight seconds
                                                                                                  • Operating Limits: -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing)
                                                                                                  • PC Requirements: Windows PC with at least one free USB or serial port (depending on interface) Software Requirements: TrendReader® 2 (Compatible with Windows XP, Vista, Windows 7 and  Windows        8 [32 bit & 64 bit])
                                                                                                  • Memory Size: 128 KB (capable of storing up to 87,000 readings)
                                                                                                  • Sampling Rates: User selectable rates from 25 per second to once every eight hours (BP-101 battery pack or PS-201 power supply required for sampling rates faster than  eight seconds)
                                                                                                  • Number of Channels: Four (one internal sensor for ambient temperature, one for pressure, and two for optional remote relative humidity and temperature probe [model EH-020A])
                                                                                                  • Internal Temperature Sensor:
                                                                                                  • Type: NTC Thermistor - 10,000 @ 25°C (77°F)
                                                                                                  • Range: -40°C to 70°C (-40°F to 158°F)
                                                                                                  • Accuracy: ±0.2°C over the range of 0°C to 70°C (± 0.3°F over the range of 32°F to 158°F)
                                                                                                  • Resolution: 0.03°C (0.05°F) @ 25°C; better than 0.07°C (0.12°F) between -25°C and 70°C (-13°F and 158°F); better than 0.13°C (0.23°F) between -40°C and -25°C (-40°F and -13°F)
                                                                                                  • Pressure Sensor:
                                                                                                  • Ranges: 0 to 10 inWC (2.5 kPa) Gauge; Resolution: 0.006 inWC (1.5 Pa)
                                                                                                  • Ranges: 0 to 5 PSI (30 kPa) Gauge; Resolution: 0.003 PSI (0.02 kPa)
                                                                                                  • Ranges: 0 to 30 PSI (200 kPa) Absolute; Resolution: 0.015 PSI (0.1 kPa)
                                                                                                  • Ranges: 0 to 30 PSI (200 kPa) Gauge; Resolution: 0.015 PSI (0.1 kPa)
                                                                                                  • Ranges: 0 to 0 to 100 PSI (700 kPa) Absolute; Resolution: 0.05 psi (0.34 kPa)
                                                                                                  • Ranges: 0 to 100 PSI (700 kPa) Gauge; Resolution: 0.05 psi (0.34 kPa)
                                                                                                  • Range: 0 to 150 PSI (1000 kPa) Gauge; Resolution: 0.05 psi (0.34 kPa)

                                                                                                  • (1) SmartReader Plus 4 Data Logger
                                                                                                  • (1) TrendReader 2 software and interface kit
                                                                                                  • (1) Instruction manual

                                                                                                    Note: Prices are not binding at any time subject to change without prior notice


                                                                                                      Options 0 Item Selected
                                                                                                    Image
                                                                                                    Model
                                                                                                    Product Name
                                                                                                    Price
                                                                                                    Available
                                                                                                    Quantity
                                                                                                    ACR Systems SmartReader Plus 4 [01-0117] Four-Channel Pressure, Temperature and Relative Humidity Data Logger, 0-30 PSI Gauge With 128 KB Memory, -40°C to 70°C (-40°F to 158°F)
                                                                                                    01-0117
                                                                                                    Rp.38.960.800
                                                                                                    4 - 6 WEEKS
                                                                                                      Accessories 0 Item Selected