×
Multiple Product

have been added to your cart

There Are items in your cart.

Cart Subtotal: $xxx.xx

Go to checkout
  • ACR Systems SmartReader Plus 4 LPD Two-Channel Low Pressure Differential and Temperature Data Logger, -40°C to 70°C (-40°F to 158°F)

ACR Systems SmartReader Plus 4 LPD Two-Channel Low Pressure Differential and Temperature Data Logger, -40°C to 70°C (-40°F to 158°F)

Not yet rated Write a review
ACR Systems Inc.

Available Options

Rp.29,053,600
Availability:
4 - 6 WEEKS
Product Code:
01-0
Brand:
ACR Systems Inc.
Update Terakhir:
23 Nov 2023
  • Free delivery

  • Money back guarantee

Ask an Expert

Our tech experts are ready to help!

(62) 021-53167044 | 0812-83861970 | 0812-9915277

Email Us

Share

The SmartReader Plus 4 LPD (Low Pressure Differential) data logger is a two channel logger with internal pressure and temperature sensors. The low pressure sensor is built into the logger and is capable of measuring low gauge and differential pressure. APPLICATIONS: Commissioning HVAC systems, monitoring air duct velocity, testing and balancing HVAC systems, monitoring wind speed, verifying positive pressure in critical facilities such as medical and manufacuring, etc.

TrendReader 2 Software
The ACR Systems TrendReader 2 Software is a powerful, versatile and easy-to-use application, designed exclusively for ACR's SmartReader Plus, SmartReader, IAQ, OWL, TRH, JR and Nautilus data loggers. Powerful features and easy setup enables collected data to be thoroughly analyzed in seconds.

Downloading and Communicating with Data Logger
Setup, download and view information from a single data logger with ACR's IC-102 interface cable (included in software interface package). Connection is simple; plug the interface cable into the USB port of your computer and connect the other end to the logger. No tools, cards or docking stations are required.

Data Logger Setup
With built-in menus for sample rate and mode, start delay, equations and more, logger setup is fast and easy. In addition, equations are already included for all ACR sensors so you need only select the appropriate equation from the menu or customize your own. Real-time readings are displayed in the Setup window, allowing you to verify that your data logger is working correctly before placing it in the field.

Viewing Data
With TrendReader 2, data can be viewed in several ways. For presentation purposes, view your collected data in graphical format or for a more detailed analysis, view your data in table format. Either way, multiple channels of data can be displayed at once. Multiple graphs can be displayed together and compounded to create new graphs. For added presentation power, add comments, change graph colors, zoom in on specific portions of data, and display your data using custom engineering units. Print or copy and paste graphs into your reports and presentations. Select all, or portions of the table and copy and paste into your favorite Windows program.

Exporting Data
Use the export function in TrendReader 2 to export your data to other programs for further analysis. Data can be exported in TXT, BMP, PDF, JPG or CSV formats.

There are no reviews for this product.

Write a review

  • Measure and Record Low Differential Pressure and Temperature
  • (5) Pressure Ranges Available with ±0.5% of Full Scale @ 25°C
  • 25/second to 8 Hour User-Selectable Sampling Rate
  • Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery
  • Continuous (FIFO) or Stop When Full Sampling Methods

  • Size: 107mm x 74mm x 22mm (4.2” x 2.9” x 0.9”)
  • Weight: 110 g (3.75 oz)
  • Case Material: Noryl® Plastic
  • Battery: 3.6 volt Lithium
  • Resolution: 12-bit (1 part in 4096)
  • Mounting: Magnetic backing or locking eyelet
  • Clock Accuracy: ± 2 seconds per day
  • Sampling Methods: Continuous (First-in First-out)*, Stop When Full (Fill-then-stop). *Not available with sample rates faster than eight seconds
  • Operating Limits: -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing)
  • PC Requirements: Windows PC with at least one free USB or serial port (depending on interface)
  • Software Requirements: TrendReader® 2 (Compatible with Windows XP, Vista, Windows 7 and  Windows 8 [32 bit & 64 bit])
  • Memory Size: 32 KB (capable of storing up to 21,500 readings)
  • Sampling Rates: User selectable rates from 25 per second to once every eight hours (BP-101 battery pack or PS-201 power supply required for sampling rates faster than  eight seconds)
  • Number of Channels: Two (one for the internal temperature sensor and one for the internal pressure sensor).
  • Internal Temperature Sensor: 
  • Type: NTC Thermistor - 10,000 Ohm @ 25°C (77°F)
  • Range: -40°C to 70°C (-40°F to 158°F)
  • Accuracy: ±0.2°C over the range of 0°C to 70°C (± 0.3°F over the range of 32°F to 158°F)
  • Resolution: 0.03°C (0.05°F) @ 25°C; better than 0.07°C (0.12°F) between -25°C and 70°C (-13°F and 158°F); better than 0.13°C (0.23°F) between -40°C and -25°C (-40°F and -13°F)
  • Pressure Sensor: 
  • Type: Silicon piezoresistive strain gauge
  • Media: Non-corrosive gases and dry air
  • Maximum Pressure: Four times full scale
  • Compensated Thermal Accuracy 0°C-70°C (32°F-158°F) ±0.01 inWC (±2.5Pa)
  • Long Term Stability ±0.01 inWC (±2.5Pa)
  • Range: ±0.5 inWC (±120 Pa) ; Accuracy: ±0.05 inWC (±12.5 Pa)*; Resolution: <0.001 inWC (0.25 Pa)
  • Range: ±2 inWC (±500 Pa); Accuracy: ±0.05 inWC (±12.5 Pa)*; Resolution:  <0.001 inWC (0.25 Pa)
  • Range: ±10 inWC (±2.5 kPa)l; Accuracy:  ±0.1 inWC (±25 Pa); Resolution: <0.01 inWC (2.5 Pa)

  • (1) SmartReader Plus 4 Data Logger
  • (1) TrendReader 2 software and interface kit
  • (1) Instruction manual

Note: Prices are not binding at any time subject to change without prior notice


  Options 0 Item Selected
Image
Model
Product Name
Price
Available
Quantity
ACR Systems SmartReader Plus 4 LPD [01-0310] Two-Channel Low Pressure Differential and Temperature Data Logger, +/- 0.5 in. Water Column With 32 KB Memory , -40°C to 70°C (-40°F to 158°F)
01-0310
Rp.29,053,600
4 - 6 WEEKS
ACR Systems SmartReader Plus 4 LPD [01-0311] Two-Channel Low Pressure Differential and Temperature Data Logger, +/- 1 in. Water Column With 32 KB Memory , -40°C to 70°C (-40°F to 158°F)
01-0311
Rp.29,053,600
4 - 6 WEEKS
ACR Systems SmartReader Plus 4 LPD [01-0312] Two-Channel Low Pressure Differential and Temperature Data Logger, +/- 2 in. Water Column With 32 KB Memory , -40°C to 70°C (-40°F to 158°F)
01-0312
Rp.29,053,600
4 - 6 WEEKS
ACR Systems SmartReader Plus 4 LPD [01-0313] Two-Channel Low Pressure Differential and Temperature Data Logger, +/- 5 in. Water Column With 32 KB Memory , -40°C to 70°C (-40°F to 158°F)
01-0313
Rp.29,053,600
4 - 6 WEEKS
ACR Systems SmartReader Plus 4 LPD [01-0314] Two-Channel Low Pressure Differential and Temperature Data Logger,+/- 10 in. Water Column With 32 KB Memory , -40°C to 70°C (-40°F to 158°F)
01-0314
Rp.29,053,600
4 - 6 WEEKS
  Accessories 0 Item Selected