  • ACR Systems SmartReader Plus 3 Eight-Channel AC Current, Voltage and Temperature Data Logger, -40°C to 70°C (-40°F to 158°F)

ACR Systems SmartReader Plus 3 Eight-Channel AC Current, Voltage and Temperature Data Logger, -40°C to 70°C (-40°F to 158°F)

Not yet rated Write a review
ACR Systems Inc.

Available Options

Rp.24.138.400
Availability:
4 - 6 WEEKS
Product Code:
01-0
Brand:
ACR Systems Inc.
Update Terakhir:
23 Nov 2023
  • Free delivery

  • Money back guarantee

Share

The ACR Systems SmartReader Plus 3 Eight-Channel (Temperature and External 0-5V DC) Data Logger with 128 KB Memory easily and accurately records AC current and voltage. Simply connect ACR's current probes (which are clamped around the power leads) and ACR's voltage transducer to the data logger and begin recording. From the data collected, you can even determine energy consumption (kWh) using ACR's powerful, versatile and easy to use software, TrendReader 2. APPLICATIONS: Determining energy consumption, monitoring 3-phase voltage and current, start-up or long-term load analysis, demand side management, electric motor maintenance scheduling, etc.

TrendReader 2 Software
The ACR Systems TrendReader 2 Software is a powerful, versatile and easy-to-use application, designed exclusively for ACR's SmartReader Plus, SmartReader, IAQ, OWL, TRH, JR and Nautilus data loggers. Powerful features and easy setup enables collected data to be thoroughly analyzed in seconds.

Downloading and Communicating with Data Logger
Setup, download and view information from a single data logger with ACR's IC-102 interface cable (included in software interface package). Connection is simple; plug the interface cable into the USB port of your computer and connect the other end to the logger. No tools, cards or docking stations are required.

Data Logger Setup
With built-in menus for sample rate and mode, start delay, equations and more, logger setup is fast and easy. In addition, equations are already included for all ACR sensors so you need only select the appropriate equation from the menu or customize your own. Real-time readings are displayed in the Setup window, allowing you to verify that your data logger is working correctly before placing it in the field.

Viewing Data
With TrendReader 2, data can be viewed in several ways. For presentation purposes, view your collected data in graphical format or for a more detailed analysis, view your data in table format. Either way, multiple channels of data can be displayed at once. Multiple graphs can be displayed together and compounded to create new graphs. For added presentation power, add comments, change graph colors, zoom in on specific portions of data, and display your data using custom engineering units. Print or copy and paste graphs into your reports and presentations. Select all, or portions of the table and copy and paste into your favorite Windows program.

Exporting Data
Use the export function in TrendReader 2 to export your data to other programs for further analysis. Data can be exported in TXT, BMP, PDF, JPG or CSV formats.

  • Measure & Record AC Current, Voltage and Temperature
  • 8 Channels: (1) Temperature and (7) 0 to 5 Volts DC Inputs
  • Temperature Measurement Range of -40°C to 70°C with a ±0.2°C Accuracy
  • 3 Memory and Data Storage Options Available (32 KB, 128K and 1.5MB)
  • 25/Second to 8 Hour User-Selectable Sampling Rate
  • 3.6 Volt Lithium Battery with 10 Year Life (Factory Replaceable)

  • Size: 107mm x 74mm x 22mm (4.2” x 2.9” x 0.9”)
  • Weight: 110 g (3.75 oz)
  • Case Material: Noryl® Plastic
  • Battery: 3.6 volt Lithium, 1 Amp-Hour
  • Resolution: 12-bit (1 part in 4096)
  • Mounting: Magnetic backing or locking eyelet
  • Clock Accuracy: ± 2 seconds per day
  • Sampling Methods: Continuous (First-in First-out)*, Stop When Full (Fill-then-stop). *Not available with sample rates faster than eight seconds
  • Operating Limits: -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing)
  • PC Requirements: Windows PC with at least one free USB or serial port (depending on interface)
  • Software Requirements: TrendReader® 2 (Compatible with Windows 2000 SP4, XP SP1 and Vista 32 bit)
  • Memory Size (3 models available): 32 KB (capable of storing up to 21,500 readings); 128KB (capable of storing up to 87,000 readings);  1.5MB (capable of storing up to 1,048,000 readings)
  • Sampling Rates: User selectable rates from 25 per second to every eight hours  (BP-101 battery pack or PS-201 power supply required for sampling rates faster  than eight seconds)
  • Number of Channels: Eight (one for internal temperature, four for AC current and three 0-5V DC inputs  for use with ACR’s voltage transducer to monitor 3-phase voltage)
  • Internal Temperature Sensor:
  • Type: NTC Thermistor - 10,000 Ohm @ 25°C (77°F)
  • Range:: -40°C to 70°C (-40°F to 158°F)
  • Accuracy: ±0.2°C over the range of 0°C to 70°C (± 0.3°F over the range of 32°F to 158°F)
  • Resolution: 0.03°C (0.05°F) @ 25°C; better than 0.07°C (0.12°F) between -25°C and 70°C (-13°F and 158°F); better than 0.13°C (0.23°F) between -40°C and -25°C (-40°F and -13°F)

  • (1) SmartReader Plus 3 Data Logger
  • (1) TrendReader 2 software and interface kit
  • (1) Instruction manual

Note: Prices are not binding at any time subject to change without prior notice


  Options 0 Item Selected
Image
Model
Product Name
Price
Available
Quantity
ACR Systems SmartReader Plus 3 [01-0011] 8-channel AC Current, Voltage & Temperature Data Logger With 32 KB Memory, -40°C to 70°C (-40°F to 158°F)
01-0011
Rp.24.138.400
2 - 4 WEEKS
ACR Systems SmartReader Plus 3 [01-0140] 8-channel AC Current, Voltage & Temperature Data Logger With 128 KB Memory, -40°C to 70°C (-40°F to 158°F)
01-0140
Rp.37.271.200
4 - 6 WEEKS
ACR Systems SmartReader Plus 3 [01-0144] 8-channel AC Current, Voltage & Temperature Data Logger With 1.5MB Memory, -40°C to 70°C (-40°F to 158°F)
01-0144
Rp.54.346.400
4 - 6 WEEKS
  Accessories 0 Item Selected