  • ACR Systems SmartReader Plus 10 SRP-010-128K [01-0132] 4-Channel (Temperature, RTD Temperature) Data Logger with 128 KB Memory , -230 to 300°C (-382 to 572°F)

ACR Systems SmartReader Plus 10 SRP-010-128K [01-0132] 4-Channel (Temperature, RTD Temperature) Data Logger with 128 KB Memory , -230 to 300°C (-382 to 572°F)

Not yet rated Write a review
ACR Systems Inc.
Rp.37.271.200
Availability:
4 - 6 WEEKS
Product Code:
01-0132
Brand:
ACR Systems Inc.
Update Terakhir:
20 Nov 2023
  • Free delivery

  • Money back guarantee

Share

The ACR Systems SmartReader Plus 10 SRP-010-128K [01-0132] 4-Channel (Temperature, RTD Temperature) Data Logger with 128 KB Memory is designed to precisely measure temperature over a wider temperature range than a thermistor without sacrificing accuracy or resolution. With four channels, measurements can be made in several different locations.

TrendReader 2 Software
The ACR Systems TrendReader 2 Software is a powerful, versatile and easy-to-use application, designed exclusively for ACR's SmartReader Plus, SmartReader, IAQ, OWL, TRH, JR and Nautilus data loggers. Powerful features and easy setup enables collected data to be thoroughly analyzed in seconds.

Downloading and Communicating with Data Logger
Setup, download and view information from a single data logger with ACR's IC-102 interface cable (included in software interface package). Connection is simple; plug the interface cable into the USB port of your computer and connect the other end to the logger. No tools, cards or docking stations are required.

Data Logger Setup
With built-in menus for sample rate and mode, start delay, equations and more, logger setup is fast and easy. In addition, equations are already included for all ACR sensors so you need only select the appropriate equation from the menu or customize your own. Real-time readings are displayed in the Setup window, allowing you to verify that your data logger is working correctly before placing it in the field.

Viewing Data
With TrendReader 2, data can be viewed in several ways. For presentation purposes, view your collected data in graphical format or for a more detailed analysis, view your data in table format. Either way, multiple channels of data can be displayed at once. Multiple graphs can be displayed together and compounded to create new graphs. For added presentation power, add comments, change graph colors, zoom in on specific portions of data, and display your data using custom engineering units. Print or copy and paste graphs into your reports and presentations. Select all, or portions of the table and copy and paste into your favorite Windows program.

Exporting Data
Use the export function in TrendReader 2 to export your data to other programs for further analysis. Data can be exported in TXT, BMP, PDF, JPG or CSV formats.

  • Part Number: 01-0132
  • Temperature range: -230 to 300°C (-382 to 572°F)
  • (3) External RTD Inputs and (1) Internal Thermistor Temperature Sensor
  • Accepts Any 4-Wire Platinum 100/1000 Ohm RTD Sensor Probe with a TCR of 0.00385
  • Internal Temperature Sensor Features A Measurement Range of -40°C to 70°C (-40°F to 158°F) and ±0.2°C Accuracy
  • Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery
  • 25/Second to 8 Hour User-Selectable Sampling Rate
  • Continuous (FIFO) or Stop When Full Sampling Methods

                                                                                                                      • Size: 107mm x 74mm x 22mm (4.2” x 2.9” x 0.9”)
                                                                                                                      • Weight: 110 g (3.75 oz)
                                                                                                                      • Case Material: Noryl® Plastic
                                                                                                                      • Battery: 3.6 volt Lithium
                                                                                                                      • Resolution: 12-bit (1 part in 4096)
                                                                                                                      • Mounting: Magnetic backing or locking eyelet
                                                                                                                      • Clock Accuracy: ± 2 seconds per day
                                                                                                                      • Sampling Methods: Continuous (First-in First-out), Stop When Full (Fill-then-stop)
                                                                                                                      •  *Not available with sample rates faster than eight seconds
                                                                                                                      • Operating Limits: -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing)
                                                                                                                      • PC Requirements: Windows PC with at least one free USB or serial port (depending on interface)
                                                                                                                      • Software Requirements: TrendReader® 2 (Compatible with Windows XP SP3, Windows Vista SP2 & Windows 7 (32 bit & 64 bit)
                                                                                                                      • Memory Size: 128 KB (capable of storing up to 87,000 readings)
                                                                                                                      • Sampling Rates: User selectable rates from 25 per second to once every eight hours (BP-101 battery pack or PS-201 power supply required for sampling rates faster than eight seconds)
                                                                                                                      • Number of Channels: Four (one internal thermistor channel for ambient temperature and three external channels for use with RTD* temperature probes) *Any RTD with a Temperature Coefficient of                Resistance (TCR) of 0.00385 can be used

                                                                                                                      • (1) Instruction Manual

                                                                                                                      Download

                                                                                                                      Note: Prices are not binding at any time subject to change without prior notice


                                                                                                                        Options 0 Item Selected
                                                                                                                      Image
                                                                                                                      Model
                                                                                                                      Product Name
                                                                                                                      Price
                                                                                                                      Available
                                                                                                                      Quantity
                                                                                                                      ACR Systems SmartReader Plus 10 SRP-010-128K [01-0132] 4-Channel (Temperature, RTD Temperature) Data Logger with 128 KB Memory , -230 to 300°C (-382 to 572°F)
                                                                                                                      01-0132
                                                                                                                      Rp.37.271.200
                                                                                                                      4 - 6 WEEKS
                                                                                                                        Accessories 0 Item Selected