Multiple Product

have been added to your cart

There Are items in your cart.

Cart Subtotal: $xxx.xx

Go to checkout
  • ACR Systems SmartReader Plus 2 [01-0113] Four-Channel Temperature and Relative Humidity Data Logger, -40°C to 70°C (-40°F to 158°F

ACR Systems SmartReader Plus 2 [01-0113] Four-Channel Temperature and Relative Humidity Data Logger, -40°C to 70°C (-40°F to 158°F

Not yet rated Write a review
ACR Systems Inc.
Rp.33,021,600
Availability:
4 - 6 WEEKS
Product Code:
01-0113
Brand:
ACR Systems Inc.
Update Terakhir:
22 Nov 2023
  • Free delivery

  • Money back guarantee

Share

The ACR Systems SmartReader Plus 2 [01-0113] four-Channel (Temperature, Relative Humidity, External RH, and External Temperature) Data Logger with 128 KB Memory is a self-contained data logger that can monitor and record temperature and relative humidity right out of the box. The on-board relative humidity (RH) sensor is temperature compensated, permitting reliable, worry-free RH readings. For remote sensing of temperature and RH, simply attach ACR's temperature/RH probe, or for remote temperature sensing, attach up to two thermistor probes. APPLICATIONS: Monitoring the transportation or storage conditions of perishable and/or pharmaceutical goods, tracking “air quality”, HVAC system testing and balancing, etc.

TrendReader 2 Software
The ACR Systems TrendReader 2 Software is a powerful, versatile and easy-to-use application, designed exclusively for ACR's SmartReader Plus, SmartReader, IAQ, OWL, TRH, JR and Nautilus data loggers. Powerful features and easy setup enables collected data to be thoroughly analyzed in seconds.

Downloading and Communicating with Data Logger
Setup, download and view information from a single data logger with ACR's IC-102 interface cable (included in software interface package). Connection is simple; plug the interface cable into the USB port of your computer and connect the other end to the logger. No tools, cards or docking stations are required.

Data Logger Setup
With built-in menus for sample rate and mode, start delay, equations and more, logger setup is fast and easy. In addition, equations are already included for all ACR sensors so you need only select the appropriate equation from the menu or customize your own. Real-time readings are displayed in the Setup window, allowing you to verify that your data logger is working correctly before placing it in the field.

Viewing Data
With TrendReader 2, data can be viewed in several ways. For presentation purposes, view your collected data in graphical format or for a more detailed analysis, view your data in table format. Either way, multiple channels of data can be displayed at once. Multiple graphs can be displayed together and compounded to create new graphs. For added presentation power, add comments, change graph colors, zoom in on specific portions of data, and display your data using custom engineering units. Print or copy and paste graphs into your reports and presentations. Select all, or portions of the table and copy and paste into your favorite Windows program.

Exporting Data
Use the export function in TrendReader 2 to export your data to other programs for further analysis. Data can be exported in TXT, BMP, PDF, JPG or CSV formats.

  • Part Number: 01-0113
  • Temperature range: -40°C to 70°C 
  • Internal Temperature and Humidity Sensors and (2) External Inputs for Additional Temp and RH
  • -40°C to 70°C and 0 to 95% RH Measurement Range with 0.2°C and ±3% RH Accuracy
  • Powered-By a Factory Replaceable 10-Year 3.6 Volt Lithium Battery
  • 25/Second to 8 Hour User-Selectable Sampling Rate
  • Continuous (FIFO) or Stop When Full Sampling Methods

        • Size: 107mm x 74mm x 22mm (4.2” x 2.9” x 0.9”)
        • Weight: 110 g (3.75 oz)
        • Case Material: Noryl® Plastic
        • Battery: 3.6 volt Lithium, 1 Amp-Hour
        • Resolution: 12-bit (1 part in 4096)
        • Mounting: Magnetic backing or locking eyelet
        • Clock Accuracy: ± 2 seconds per day
        • Sampling Methods: Continuous (First-in First-out)*, Stop When Full (Fill-then-stop).  *Not available with sample rates faster than eight seconds.
        • Operating Limits: -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing)
        • PC Requirements: Windows PC with at least one free USB or serial port (depending on interface)
        • Software Requirements: TrendReader® 2 (Compatible with Windows XP, Vista, Windows 7 and  Windows 8 [32 bit & 64 bit])
        • Memory Size: 128 KB (capable of storing up to 87,000 readings)
        • Sampling Rates: User selectable rates from 25 per second to once every eight hours  (BP-101 battery pack or PS-201 power supply required for sampling rates faster  than eight seconds)
        • Number of Channels: Four (one for the internal temperature sensor, one for the internal RH sensor  and two for remote measurements of temperature and RH [with ACR’s EH-020A probe])
        • Internal Temperature Sensor:
        • Type: NTC Thermistor - 10,000 Ohm @ 25°C (77°F)
        • Range: -40°C to 70°C (-40°F to 158°F)
        • Accuracy: ±0.2°C over the range of 0 to 70°C (± 0.3°F over the range of 32 to 158°F)
        • Resolution: 0.03°C (0.05°F) @ 25°C; better than 0.07°C (0.12°F) between -25°C and  70°C (-13°F and 158°F); better than 0.13°C (0.23°F) between -40°C and  -25°C (-40°F and -13°F)
        • Internal Relative Humidity Sensor:
        • Type: Capactive thin polymer film
        • Range: 0 to 95% RH (non-condensing)
        • Accuracy: ±3% RH from 10 to 90% RH (-20°C to 40°C [-4°F to 104°F])
        • Resolution: Better than 0.04% RH between 25% and 60% RH @ 25°C (77°F)
        • Chemical Tolerances: Organic solvents typically 1,000 to 10,000 ppm Corrosive agents (strong acids S02, H2S04, C12, HC1, H2S etc.) typically 1 to 10 ppm; Weak acids typically 100 to 1,000 ppm; Bases typically 10,000 to 100,000 ppm

        • (1) SmartReader Plus 2 Data Logger
        • (1) TrendReader 2 software and interface kit
        • (1) Instruction manual

        Note: Prices are not binding at any time subject to change without prior notice


          Options 0 Item Selected
        Image
        Model
        Product Name
        Price
        Available
        Quantity
        ACR Systems SmartReader Plus 2 [01-0113] Four-Channel Temperature and Relative Humidity Data Logger, -40°C to 70°C (-40°F to 158°F
        01-0113
        Rp.33,021,600
        4 - 6 WEEKS