• Fluke Calibration 9173 [9173-A-R-256] Field Dry-Well Metrology Temperature Calibrator with Model 9173-INSA ("A" Insert), INSX and Reference Thermometry, 50 to 700°C (122 to 1292°F)

Fluke Calibration 9173 [9173-A-R-256] Field Dry-Well Metrology Temperature Calibrator with Model 9173-INSA ("A" Insert), INSX and Reference Thermometry, 50 to 700°C (122 to 1292°F)

Not yet rated Tulis ulasan
Rp.318.500.000
Ketersediaan:
4 - 6 MINGGU
Kode Produk:
9173-A-R-256
Merk:
Fluke

  • Free delivery

  • Money back guarantee

Share

The Fluke Calibration 9173AR256 Field Dry-Well Metrology Temperature Calibrator with Model 9173-INSA ("A" Insert), INSX and Reference Thermometry, 50 °C to 700 lets you bring lab-quality performance into whatever field environment you might work in. New analog and digital control techniques provide stability as good as ±0.005 °C. And with dual-zone control, axial (or "vertical") uniformity is as good as ±0.02 °C over a 60 mm (2.36 in.) zone.

There are six critical components of performance in an industrial heat source (which the European metrology community explains, for example, in the document EA-10/13): calibrated display accuracy, stability, axial (vertical) uniformity, radial (well-to-well) uniformity, impact from loading, and hysteresis. Fluke Calibration added a seventh in the form of a legitimate reference thermometer input and created an entirely new product category: Metrology Wells..



Features:


  • Features INSX reference thermometry
  • 1973
    • Temperature range (at 23 °C ambient): 50 °C to 700 °C (122 °F to 1292 °F)
    • Display accuracy: ±0.2 °C: 50 °C to 425 °C; ±0.25 °C: 425 °C to 660 °C
    • Stability: ±0.005 °C: 50 °C to 100 °C; ±0.01 °C: 100 °C to 425 °C; ±0.03 °C: 425 °C to 700 °C
    • Axial uniformity: ±0.1 °C: 50 °C to 100 °C; ±0.25 °C: 100 °C to 425 °C; ±0.4 °C: 425 °C to 700 °C
    • Radial uniformity: ±0.01 °C: 50 °C to 100 °C; ±0.025 °C: 100 °C to 425 °C; ±0.04 °C: 425 °C to 700 °C
    • Built-in reference input:
    • Temperature range: -200 °C to 962 °C (-328 °F to 1764 °F)
    • Resistance range: 0 Ohm to 400 Ohm, auto-ranging
    • Characterizations: ITS-90 subranges 4, 6, 7, 8, 9, 10, and 11 Callendar-Van Dusen (CVD): R0, α, β, δ
    • Resistance accuracy: 0 Ohm to 20 Ohm: 0.0005 Ohm; 20 Ohm to 400 Ohm: 25 ppm
    • Immersion depth to 203 mm (8 in.)
    • Combines bath-level performance with dry-well functionality and legitimate reference thermometry
    • Bring lab-quality performance into whatever field environment you might work in
  • 9173-INSA
    • Six imperial miscellaneous holes
    • Hole quantities and sizes: 3 Holes, 1/4 in.; 1 Hole, 3/16 in.; 1 Hole, 3/8 in.; 1 Hole, 1/8 in.
    • Removable inserts sized for probes with named diameter
    • Use additional inserts to broaden range of hole sizes available
    • For use with Model 9173


What's In The Box:


  • (1) "A" Insert
  • (1) Power Cord
  • (1) RS-232 Cable
  • (1) Getting Started Guide
  • (1) User Manual
  • (1) Report of Calibration and Calibration Label
  • (1) DIN Connector
  • (1) Insert Removal Tool
  • (1) 9930 Interface-it Software and User Manual


Brochure/Datasheet


Instruction manual