• PCE Instruments PCE8303 [PCE-830-3] Three Phase Power Data Logger Meter w/ 3 x PCE-3007 Flexible Current Probe (3000A)

PCE Instruments PCE8303 [PCE-830-3] Three Phase Power Data Logger Meter w/ 3 x PCE-3007 Flexible Current Probe (3000A)

Not yet rated Write a review
PCE Instruments
Rp.77.390.600
Availability:
4 - 6 WEEKS
Product Code:
PCE-830-3
Brand:
PCE Instruments
Update Terakhir:
13 Sep 2023
  • Free delivery

  • Money back guarantee

Share

PCE-830-3 Clamp Meter with 3 phases / Measures power and analyses harmonics / Includes memory, interface, and software.
The PCE-830 Clamp Meter is used for measuring one to three phases of electrical quantities for alternating current (AC). This Clamp Meter also measures parameters such as voltage, current, frequency, harmonics, and power as well as indicating, according to standard EN50160, harmonic values, interharmonics, and asymmetrics. Interference, such as interruptions, leaks, overloads, or transience (from 16 µs) are detected with their corresponding values. The backlit LCD, with high resolution, can show up to 35 parameters simultaneously. Up to 3 clips can be attached at the same time to the Clamp Meter. In data logger mode, it can save up to 17,470 readings (3 phases / 4 conductors), in a simpler set up (1 phase / 2 conductors) it can save up to 52,400 readings, split into 85 groups. All this makes the PCE-830 Clamp Meter the ideal instrument for taking measurements over long durations. Measurement values obtained can be sent to a computer and be processed with the included analysis software. The device comes with everything needed to be measuring and analyzing from the moment it arrives. Although the Clamp Meter comes calibrated from the manufacturer, an optional laboratory calibration and certificate, that meets ISO standards, can be ordered separately with the device or when a recalibration is required.

  • Part Number: PCE-830-3
  • Current Probe: PCE-3007 Flexible Current Probe (3000A)
  • ISO Calibration Certificate: Not Included
  • Analysis of a network of 3 phases / 4 conductors, 3 phases / 3 conductors, 1 phase / 2 conductors, 1 phase / 3 conductors
  • Measures effective real value (V 123 and I 123)
  • Measures active power (W, KW, MW, GW)
  • Measures apparent and reactive power (KVA, KVAR)
  • Power Factor (PF), phase angle (Φ)
  • Measures energy and work (Wh, KWh, KVARh, PFh)
  • Measures current from 0.1 mA to 3000 A, allowing for the reserve power of a factory to be determined
  • Large LCD that shows up to 35 parameters simultaneously (3P4W [=3 phases/4 conductors])
  • CT conditions (1 to 600) and PT (1 to 3000) are programmable
  • Indicates current wave forms and voltage overlap.
  • 512 KB of memory with programmable intervals to save data every 2 to 3000 seconds, 17,470 readings using the system of 3 phases / 4 conductors
  • Indicates wave forms, efficiency parameters, and harmonic distortion
  • Backlit LCD with dot matrix
  • Average power (AD in W, KW, MW)
  • Maximum power (MD in W, KW, MW) with the programmable period
  • Analysis of harmonic distortion up to a curvature of 99
  • Indication of up to 50º form of harmonic wave
  • Indication of the wave form with maximum value (1024 readings / period)
  • Analysis of absolute distortion (%THD-F)
  • Diagram of graphic equilibrium with parameters of a 3 phase system
  • Detects up to 28 transistors (time and cycles) with a programmable threshold (%)
  • Relation of 3 phases of voltage or asymmetrical current (VUR)
  • Factor of 3 phases of voltage and asymmetrical current (d0%, d2%)
  • USB port (optically insulated)
  • Integrated timer and calendar to record data
  • Maximum diameter of the electrical conductor for the amp clamp: the PCE-6801 ~30 mm / 1.2 in, PCE-6802 ~ 55 mm / 2.2 in, PCE-3007 ~170 mm / 6.7 in

  • PCE-830 + PCE-6801:
  • Range: 0.0 – 20.0 %; Resolution: 0.1%; Accuracy: ± 1%
  • Range: 20.0 – 100%; Resolution: 0.1%; Accuracy: ±3% of reading ± 5%
  • Range: 100 – 999.9%; Resolution: 0.1%; Accuracy: ±10% of reading ±10%
  • PCE-830 + PCE-6802: 
  • Range: 0.0 – 20.0 %; Resolution: 0.1%; Accuracy: ± 1%
  • Range: 20.0 – 100%; Resolution: 0.1%; Accuracy: ±3% of reading ± 5%
  • Range: 100 – 999.9%; Resolution: 0.1%; Accuracy: ±10% of reading ±10%
  • PCE-830 + PCE-3007: 
  • Range: 0.0 – 20.0 %; Resolution: 0.1%; Accuracy: ± 2%
  • Range: 20.0 – 100%; Resolution: 0.1%; Accuracy: ± 6% of reading ± 1%
  • Range: 100 – 999.9%; Resolution: 0.1%; Accuracy: ± 10% of reading ± 1% 
  • PCE-830 Analyzer:
  • Indoors: Use
  • Battery Type: 1.5V SUM-3 x 8
  • External DC Input: Use only power supply adapter Model PHAPSA
  • Display: Dot Matrix LCD (240x128) with backlight
  • LCD Update Rate: 1 time / second
  • Power Consumption: 140mA (approx.)
  • No. Of Samples: 1024 samples / period
  • Data Logging Files: 85
  • Max. File Capacity: 17474 records (3P4W, 3P3W);  26210 records (1P3W); 52420 records (1P2W);  4096 records (50 Harmonics / record)
  • Sampling Time: 2 to 3000 seconds for data logging
  • Low battery Indication: 
  • Overload Indication: OL
  • Operating Temperature: -10°C to 50°C
  • Operating Humidity: less than 85% relative
  • Storage Temperature: -20°C to 60°C
  • Storage Humidity: less than 75% relative
  • Dimension: 257(L) x 155(W) x 57(H) mm  10.1”(L) x 6.1”(W) x 2.3”(H)
  • Weight: 1160g (Batteries included)
  • PCE-6801 Current Probe (100A):
  • Conductor Size: 30mm (approx.)
  • Range Selection: Manual (1A, 10A, 100A)
  • Cable Length: 3000mm
  • Battery: powered by power analyzer
  • Dimension: 210mm (L) x 62mm (W) x 36mm (H)  8.3" (L) x 2.5" (W) x 1.4" (H)
  • Weight: 200g 
  • PCE-6802 Current Probe (1000A):
  • Conductor Size: 55mm (approx.), 64 x 24mm (bus bar)
  • Range Selection: Manual (10A, 100A, 1000A)
  • Cable Length: 3000mm
  • Battery: powered by power analyzer
  • Dimension: 244mm (L) x 97mm (W) x 46mm (H)
  •  9.6" (L) x 3.8" (W) x 1.8" (H)
  • Weight: 600g
  • PCE-3007 Flexible Current Probe (3000A):
  • Probe Length: 3007-24 24 in / 610 mm
  • Minimum Bending Diameter: 35mm
  • Connector Diameter: 23mm
  • Cable Diameter: 14mm
  • Cable Length from Probe to Box: 1700mm
  • Cable Length from Box to Output: 1700mm
  • Range Selection: Manual (300A, 3000A)
  • Battery: powered by power analyzer
  • Dimension (Box): 130mm(L) x 80mm(W)x 43mm(H)  5.1”(L) x 3.1”(W) x 1.7”(H)
  • Weight: 410g 

  • (1) PCE-830-3 Clamp Meter
  • (3) Amp clamps - PCE-3007
  • (4) Alligator clips
  • (4) Safety test lines (3 m / 3.3 ft long)
  • (8) Batteries
  • (1) Mains adaptor
  • (1) Carrying case
  • (1) USB cable software
  • (1) User's manual

Download