• Bacharach HGM-MZ Multi-Zone Gas Leak Monitor, Ammonia Without Remote Display

Bacharach HGM-MZ Multi-Zone Gas Leak Monitor, Ammonia Without Remote Display

Not yet rated Write a review
Bacharach

Available Options

Rp.181.976.360
Availability:
4 - 6 WEEKS
Product Code:
3015
Brand:
Bacharach
Update Terakhir:
15 Nov 2022
  • Free delivery

  • Money back guarantee

Share

The Bacharach HGM-MZ Multi-zone Gas Leak Monitor offers superior performance, flexibility and functionality for low level continuous monitoring of refrigerant gases used in most commercial systems including: Chlorofluorocarbons (CFC), Hydrochlorofluorocarbons (HCFC), Hydrofluorocarbons (HFC), Ammonia (NH3) and Carbon Dioxide (CO2). These state-of-the-art fixed gas monitors lead the industry in performance, integration capabilities, initial cost and cost of ownership. Capable of detecting more than 38 refrigerant gases, the Multi-Zone system is compliant with ASHRAE standard 15-2007, is ETL Energy Saving Listed, meets California Code Regulations for Refrigerant Monitors and is EN 14624 and CE certified.

The Multi-Zone is not only a leak detection system, but enables refrigerant management of e.g. a whole supermarket. The sooner a loss of refrigerant is detected, the earlier countermeasures can be initiated, resulting in smaller recharge quantities of refrigerants. With the on-board relays and the optional remote display, the Multi-Zone fulfills the regulatory requirements as a refrigerant detection system. Using the Modbus interface or analog output, the monitor can be integrated into any BMS/BAS system.

Bacharach HGM-MZ Multi-zone monitors provide continuous detection of refrigerant gas levels in up to 16 separate test zones and can be fitted with an optional two channel 4-20 mA current loop board for connection to remote monitoring equipment. Multi-Zone monitors retain a log of previous readings that can be easily accessed for analysis. Four relay contacts are provided that can be programmed to trigger external alarm devices in the event of a system fault, or if a leak (small), spill (medium) or evacuation (large) level of gas is detected, while audible and visual front panel indicators show alarm and fault conditions. With only minor periodic maintenance, such as the occasional replacement of filters, and active diagnostics that continuously check the system for proper operation, Multi-Zone monitors help maintain your equipment efficiency, promote safety and protect the environment.


  • 4 to 16 point sampling system using IR (NDIR) sensor technology, expandable to 48 points
  • Low detection limits (as low as 1 ppm)
  • Long sampling distances (up to 1,200 ft / 365 m)
  • On-board visual/audible alarms, 4 relay contacts mitigates refrigerant loss
  • Detects refrigerants (CFCs, HFCs, HCFCs, HFOs), ammonia, carbon dioxide
  • Measuring Range: Refrigerants: 0 to 10,000 ppm; Ammonia: 25 to 10,000 ppm; Carbon Dioxide: 300 to 8,000 ppm
  • Accuracy: Refrigerants: up to ±1 ppm ±10% of reading; Ammonia: up to ±10 ppm ±10% of reading; CO2: up to ±5 ppm ±5% of reading
  • Modbus RTU via RS 485 digital output
  • Large Graphic LCD for easy set-up andreal-time monitoring
  • Powder-coated aluminum enclosure
  • Approvals: CE, UL, CSA, EN 61010-1, EN 61326, EN 14624

                                • Sensor Channels: 4 to 16
                                • Sample Points: 48
                                • Measuring Range: Refrigerants: 0 to 10,000 ppm, Ammonia: 25 to 10,000 ppm Carbon Dioxide: 300 to 8,000 ppm
                                • Sensitivity / Minimum Detection Limit: Refrigerants: 1 ppm, Ammonia: 10 ppm, Carbon Dioxide: 10 ppm
                                • Accuracy: ±1 ppm ±10% from 0-1000 ppm (refrigerants); ±10 ppm ±10% from 0-10,000 ppm (Ammonia); ±5 PPM ±5% from 300-1000 ppm (CO2)
                                • Resolution: 1 ppm
                                • Enclosure Rating: General Purpose
                                • Sampling Distance: 0 to 1,200' (0 to 365 m)
                                • User Interface: Backlit, graphic LCD 160 x 128 pixel; three status LEDs
                                • Power: 100 to 240 VAC, 50/60 Hz, 20W
                                • Analog Communications: 4 to 20 mA (optional)
                                • Digital Communications: Modbus RTU via RS 485
                                • Operating Voltage: 100 to 240 VAC, 50 / 60 Hz
                                • Relay Rating: 3 alarm relays, 1 fault relay, SPDT
                                • Wiring: 5 A @ 250 VAC, resistive load
                                • Alarm: Integrated Audible / Visual Alarm
                                • Ambient Temperature: 32 to 122°F (0 to 50°C)
                                • Humidity: 5 to 90 %RH, non condensing
                                • Altitude: 0 to 6,560 ft (2,000 m)
                                • Status Indicator: LCD, LEDs
                                • Buzzer Volume: 80 dB @ 10 cm
                                • Product Dimensions (L×W×H): 13.7” × 12.3” × 5” (350 × 315 × 130 mm)
                                • Product Weight: 15 lbs. (6.8 kg)
                                • Sensor Type: NDIR
                                • Expected Sensor Service Life: 10 Years
                                • Approvals: CE, UL, CSA, EN 61010-1, EN 61326, EN 14624
                                • Warranty: 2 Years
                                • Country of Origin: United States

                                                                                    • (5) Line-End Filters
                                                                                    • (1) Charcoal Filter (Halogen Gas Monitor Only)
                                                                                    • (3) End-of-line Water-Stop Filter Assembly
                                                                                    • (1) T-Bolt Bracket (Halogen Gas Monitor Only)
                                                                                    • (1) Multi-Zone Instruction Manual

                                                                                          Download

                                                                                          Note: Prices are not binding at any time subject to change without prior notice