Options 0 Item Selected
Image
Model
Product Name
Price
Available
Quantity
Additel ADT260EX [ADT260EX-V15-BAR-N] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe,1/4NPT male, 0.02%FS, -1 to 0 bar, Gauge Pressure
ADT260EX-V15-BAR-N
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-V15-BAR-N2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe,1/2NPT male, 0.02%FS, -1 to 0 bar, Gauge Pressure
ADT260EX-V15-BAR-N2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-V15-BAR-B] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe,1/4BSP male, 0.02%FS, -1 to 0 bar, Gauge Pressure
ADT260EX-V15-BAR-B
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-V15-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe,1/2BSP male, 0.02%FS, -1 to 0 bar, Gauge Pressure
ADT260EX-V15-BAR-B2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP2-BAR-N] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4NPT male, 0.02%FS, 0 to 0.16 bar, Gauge Pressure
ADT260EX-GP2-BAR-N
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP2-BAR-N2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2NPT male, 0.02%FS, 0 to 0.16 bar, Gauge Pressure
ADT260EX-GP2-BAR-N2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP2-BAR-B] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4BSP male, 0.02%FS, 0 to 0.16 bar, Gauge Pressure
ADT260EX-GP2-BAR-B
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP2-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.02%FS, 0 to 0.16 bar, Gauge Pressure
ADT260EX-GP2-BAR-B2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP5-BAR-N] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4NPT male, 0.05%FS, 0 to 0.35 bar, Gauge Pressure
ADT260EX-GP5-BAR-N
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP5-BAR-N2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2NPT male, 0.05%FS, 0 to 0.35 bar, Gauge Pressure
ADT260EX-GP5-BAR-N2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP5-BAR-B] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4BSP male, 0.05%FS, 0 to 0.35 bar, Gauge Pressure
ADT260EX-GP5-BAR-B
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP5-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.05%FS, 0 to 0.35 bar, Gauge Pressure
ADT260EX-GP5-BAR-B2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP10-BAR-N] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4NPT male, 0.02%FS, 0 to 0.7 bar, Gauge Pressure
ADT260EX-GP10-BAR-N
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP10-BAR-N2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2NPT male, 0.02%FS, 0 to 0.7 bar, Gauge Pressure
ADT260EX-GP10-BAR-N2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP10-BAR-B] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4BSP male, 0.02%FS, 0 to 0.7 bar, Gauge Pressure
ADT260EX-GP10-BAR-B
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP10-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.02%FS, 0 to 0.7 bar, Gauge Pressure
ADT260EX-GP10-BAR-B2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP15-BAR-N] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4NPT male, 0.02%FS, 0 to 1 bar, Gauge Pressure
ADT260EX-GP15-BAR-N
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP15-BAR-N2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2NPT male, 0.02%FS, 0 to 1 bar, Gauge Pressure
ADT260EX-GP15-BAR-N2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP15-BAR-B] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4BSP male, 0.02%FS, 0 to 1 bar, Gauge Pressure
ADT260EX-GP15-BAR-B
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP15-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.02%FS, 0 to 1 bar, Gauge Pressure
ADT260EX-GP15-BAR-B2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP30-BAR-N] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4NPT male, 0.02%FS, 0 to 2 bar, Gauge Pressure
ADT260EX-GP30-BAR-N
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP30-BAR-N2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2NPT male, 0.02%FS, 0 to 2 bar, Gauge Pressure
ADT260EX-GP30-BAR-N2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP30-BAR-B] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4BSP male, 0.02%FS, 0 to 2 bar, Gauge Pressure
ADT260EX-GP30-BAR-B
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP30-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.02%FS, 0 to 2 bar, Gauge Pressure
ADT260EX-GP30-BAR-B2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP50-BAR-N] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4NPT male, 0.02%FS, 0 to 3.5 bar, Gauge Pressure
ADT260EX-GP50-BAR-N
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP50-BAR-N2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2NPT male, 0.02%FS, 0 to 3.5 bar, Gauge Pressure
ADT260EX-GP50-BAR-N2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP50-BAR-B] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4BSP male, 0.02%FS, 0 to 3.5 bar, Gauge Pressure
ADT260EX-GP50-BAR-B
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP50-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.02%FS, 0 to 3.5 bar, Gauge Pressure
ADT260EX-GP50-BAR-B2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP100-BAR-N] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4NPT male, 0.02%FS, 0 to 7 bar, Gauge Pressure
ADT260EX-GP100-BAR-N
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP100-BAR-N2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2NPT male, 0.02%FS, 0 to 7 bar, Gauge Pressure
ADT260EX-GP100-BAR-N2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP100-BAR-B] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4BSP male, 0.02%FS, 0 to 7 bar, Gauge Pressure
ADT260EX-GP100-BAR-B
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP100-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.02%FS, 0 to 7 bar, Gauge Pressure
ADT260EX-GP100-BAR-B2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP150-BAR-N] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4NPT male, 0.02%FS, 0 to 10 bar, Gauge Pressure
ADT260EX-GP150-BAR-N
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP150-BAR-N2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2NPT male, 0.02%FS, 0 to 10 bar, Gauge Pressure
ADT260EX-GP150-BAR-N2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP150-BAR-B] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4BSP male, 0.02%FS, 0 to 10 bar, Gauge Pressure
ADT260EX-GP150-BAR-B
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP150-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.02%FS, 0 to 10 bar, Gauge Pressure
ADT260EX-GP150-BAR-B2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP300-BAR-N] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4NPT male, 0.02%FS, 0 to 20 bar, Gauge Pressure
ADT260EX-GP300-BAR-N
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP300-BAR-N2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2NPT male, 0.02%FS, 0 to 20 bar, Gauge Pressure
ADT260EX-GP300-BAR-N2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP300-BAR-B] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4BSP male, 0.02%FS, 0 to 20 bar, Gauge Pressure
ADT260EX-GP300-BAR-B
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP300-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.02%FS, 0 to 20 bar, Gauge Pressure
ADT260EX-GP300-BAR-B2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP500-BAR-N] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4NPT male, 0.02%FS, 0 to 35 bar, Gauge Pressure
ADT260EX-GP500-BAR-N
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP500-BAR-N2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2NPT male, 0.02%FS, 0 to 35 bar, Gauge Pressure
ADT260EX-GP500-BAR-N2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP500-BAR-B] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4BSP male, 0.02%FS, 0 to 35 bar, Gauge Pressure
ADT260EX-GP500-BAR-B
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP500-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.02%FS, 0 to 35 bar, Gauge Pressure
ADT260EX-GP500-BAR-B2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP600-BAR-N] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4NPT male, 0.02%FS, 0 to 40 bar, Gauge Pressure
ADT260EX-GP600-BAR-N
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP600-BAR-N2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2NPT male, 0.02%FS, 0 to 40 bar, Gauge Pressure
ADT260EX-GP600-BAR-N2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP600-BAR-B] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4BSP male, 0.02%FS, 0 to 40 bar, Gauge Pressure
ADT260EX-GP600-BAR-B
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP600-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.02%FS, 0 to 40 bar, Gauge Pressure
ADT260EX-GP600-BAR-B2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP1K-BAR-N] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4NPT male, 0.02%FS, 0 to 70 bar, Gauge Pressure
ADT260EX-GP1K-BAR-N
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP1K-BAR-N2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2NPT male, 0.02%FS, 0 to 70 bar, Gauge Pressure
ADT260EX-GP1K-BAR-N2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP1K-BAR-B] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4BSP male, 0.02%FS, 0 to 70 bar, Gauge Pressure
ADT260EX-GP1K-BAR-B
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP1K-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.02%FS, 0 to 70 bar, Gauge Pressure
ADT260EX-GP1K-BAR-B2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP1.5K-BAR-N] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4NPT male, 0.02%FS, 0 to 100 bar, Gauge Pressure
ADT260EX-GP1.5K-BAR-N
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP1.5K-BAR-N2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2NPT male, 0.02%FS, 0 to 100 bar, Gauge Pressure
ADT260EX-GP1.5K-BAR-N2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP1.5K-BAR-B] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4BSP male, 0.02%FS, 0 to 100 bar, Gauge Pressure
ADT260EX-GP1.5K-BAR-B
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP1.5K-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.02%FS, 0 to 100 bar, Gauge Pressure
ADT260EX-GP1.5K-BAR-B2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP2K-BAR-N] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4NPT male, 0.02%FS, 0 to 140 bar, Gauge Pressure
ADT260EX-GP2K-BAR-N
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP2K-BAR-N2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2NPT male, 0.02%FS, 0 to 140 bar, Gauge Pressure
ADT260EX-GP2K-BAR-N2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP2K-BAR-B] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4BSP male, 0.02%FS, 0 to 140 bar, Gauge Pressure
ADT260EX-GP2K-BAR-B
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP2K-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.02%FS, 0 to 140 bar, Gauge Pressure
ADT260EX-GP2K-BAR-B2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP3K-BAR-N] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4NPT male, 0.02%FS, 0 to 200 bar, Gauge Pressure
ADT260EX-GP3K-BAR-N
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP3K-BAR-N2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2NPT male, 0.02%FS, 0 to 200 bar, Gauge Pressure
ADT260EX-GP3K-BAR-N2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP3K-BAR-B] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4BSP male, 0.02%FS, 0 to 200 bar, Gauge Pressure
ADT260EX-GP3K-BAR-B
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP3K-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.02%FS, 0 to 200 bar, Gauge Pressure
ADT260EX-GP3K-BAR-B2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP5K-BAR-N] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4NPT male, 0.02%FS, 0 to 350 bar, Gauge Pressure
ADT260EX-GP5K-BAR-N
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP5K-BAR-N2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2NPT male, 0.02%FS, 0 to 350 bar, Gauge Pressure
ADT260EX-GP5K-BAR-N2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP5K-BAR-B] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4BSP male, 0.02%FS, 0 to 350 bar, Gauge Pressure
ADT260EX-GP5K-BAR-B
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP5K-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.02%FS, 0 to 350 bar, Gauge Pressure
ADT260EX-GP5K-BAR-B2
Rp.137.572.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP10K-BAR-N] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4NPT male, 0.02%FS, 0 to 700 bar, Gauge Pressure
ADT260EX-GP10K-BAR-N
Rp.139.952.800
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP10K-BAR-N2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2NPT male, 0.02%FS, 0 to 700 bar, Gauge Pressure
ADT260EX-GP10K-BAR-N2
Rp.139.952.800
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP10K-BAR-B] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4BSP male, 0.02%FS, 0 to 700 bar, Gauge Pressure
ADT260EX-GP10K-BAR-B
Rp.139.952.800
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP10K-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.02%FS, 0 to 700 bar, Gauge Pressure
ADT260EX-GP10K-BAR-B2
Rp.139.952.800
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP15K-BAR-N] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4NPT male, 0.05%FS, 0 to 1000 bar, Gauge Pressure
ADT260EX-GP15K-BAR-N
Rp.136.804.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP15K-BAR-N2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2NPT male, 0.05%FS, 0 to 1000 bar, Gauge Pressure
ADT260EX-GP15K-BAR-N2
Rp.136.804.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP15K-BAR-B] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/4BSP male, 0.05%FS, 0 to 1000 bar, Gauge Pressure
ADT260EX-GP15K-BAR-B
Rp.136.804.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP15K-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.05%FS, 0 to 1000 bar, Gauge Pressure
ADT260EX-GP15K-BAR-B2
Rp.136.804.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP20K-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.05%FS, 0 to 1400 bar, Gauge Pressure
ADT260EX-GP20K-BAR-B2
Rp.140.772.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP20K-BAR-AF] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, Autoclave F-250-C female, 0.05%FS, 0 to 1400 bar, Gauge Pressure
ADT260EX-GP20K-BAR-AF
Rp.140.772.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP25K-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.05%FS, 0 to 1600 bar, Gauge Pressure
ADT260EX-GP25K-BAR-B2
Rp.143.332.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP25K-BAR-AF] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, Autoclave F-250-C female, 0.05%FS, 0 to 1600 bar, Gauge Pressure
ADT260EX-GP25K-BAR-AF
Rp.143.332.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP30K-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.05%FS, 0 to 2000 bar, Gauge Pressure.
ADT260EX-GP30K-BAR-B2
Rp.150.500.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP30K-BAR-AF] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, Autoclave F-250-C female, 0.05%FS, 0 to 2000 bar, Gauge Pressure
ADT260EX-GP30K-BAR-AF
Rp.150.500.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP36K-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.05%FS, 0 to 2500 bar, Gauge Pressure.
ADT260EX-GP36K-BAR-B2
Rp.157.284.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP36K-BAR-AF] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, Autoclave F-250-C female, 0.05%FS, 0 to 2500 bar, Gauge Pressure
ADT260EX-GP36K-BAR-AF
Rp.157.284.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP40K-BAR-B2] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, 1/2BSP male, 0.05%FS, 0 to 2800 bar, Gauge Pressure.
ADT260EX-GP40K-BAR-B2
Rp.162.404.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP40K-BAR-AF] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, Autoclave F-250-C female, 0.05%FS, 0 to 2800 bar, Gauge Pressure
ADT260EX-GP40K-BAR-AF
Rp.162.404.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP50K-BAR-AF] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, Autoclave F-250-C female, 0.1%FS, 0 to 3500 bar, Gauge Pressure
ADT260EX-GP50K-BAR-AF
Rp.171.492.000
4 - 6 WEEKS
Additel ADT260EX [ADT260EX-GP60K-BAR-AF] Handheld Multichannel Reference Recorder, ATEX Certified Intrinsically Safe, Autoclave F-250-C female, 0.1%FS, 0 to 4200 bar, Gauge Pressure
ADT260EX-GP60K-BAR-AF
Rp.188.004.000
4 - 6 WEEKS
  Accessories 0 Item Selected
×
Multiple Product

have been added to your cart

There Are items in your cart.

Cart Subtotal: $xxx.xx

Go to checkout

Additel ADT260EX Multichannel Reference Recorder (BAR)

Not yet rated Write a review

Available Options

Rp.137.572.000
Availability:
4 - 6 WEEKS
Product Code:
ADT260EX
Brand:
Additel
Update Terakhir:
07 Dec 2023
  • Free delivery

  • Money back guarantee

Share

The Additel 260Ex is an intrinsically safe handheld multichannel reference recorder with 8 different channel configurations. This Additel versatile and capable handheld, technicians are now able to measure and collect data for pressure, temperature (RTD probes available), barometric pressure and electrical measurement all in one highly portable device. The powerful logging capability and high-level of intrinsic safety make the ADT260Ex the perfect companion for use in the pipeline industry by supporting hydrostatic pressure testing, air leak testing, inlet and outlet pressure testing at pump stations, safety valve and ex-proof membrane testing, wellhead pressure testing, pipeline filter testing, differential pressure transmitter/flow computing testing, as well as routine calibration of pressure devices. The user-friendly Additel 260EX has a 4.4in color display that can be used in direct sunlight and is backlit for low-light spaces. The Additel 260EX has 4, 5, 6 digit resolution with a smartphone like interface.

Intrinsically Safe
The ADT260EX has passed the most stringent ATEX, IECEX, CSA, and UKCA intrinsic safety certifications. Each unit complies with a certification level of Ex ia IIC T4 Ga. This highly qualified reference recorder can be widely used in potentially explosive gas environments, such as oil and gas platforms, refineries, chemical and petrochemical plants, pharmaceutical industry, energy and gas processing industry.

Datalogging Capabilities
The Additel 260EX includes a sizable built-in automatic recording capability which supports multi parameter logging, trend curve display, local curve observation and statistical feedback. The logged results are stored onboard and can be viewed locally. The data storage capacity is up to 10 million readings (single channel) with a logging interval that is configurable from 0.1s to 9999s.

8 Channels Data Recorder
  • Pressure - Built-in module x 1; External module x2; Built-in barometer x1
  • Temperature - RTD x2
  • Electrical - Measures current, voltage, frequency, loop power, pulse or switch testing x 1
  • Simulated - Differential pressure

Write a review