The new CAT4 is designed to identify buried utilities much faster and is the perfect locator in the industry to get the results you want. Its digital platform delivers highly refined locate capabilities, specifically designed to help you find more buried utilities. The CAT4 Avoidance Mode lets the user check an intended excavation area for Power, Radio and Genny signals, which recognises located utilities in a single scan.

To further enhance the locator’s performance, put it together with the Genny4 in Genny mode and make your task much easier and quicker when detecting. A cable avoidance tool is quick and simple to use and all levels of staff can be trained to use the equipment in less than a day, which could potentially prevent any costly or fatal incidents occurring.


There are no reviews for this product.

Write a review

Detect More, Detect Faster
The new C.A.T4 digital platform delivers highly refined locate capabilities, specifically designed to help the operator find more buried utilities. The C.A.T4 Avoidance Mode™ lets the operator check an intended excavation area for Power, Radio and Genny signals, and pinpoint located utilities in a single scan. Features such as the bargraph 'tidemark' enable an operator to quickly spot a peak response and zero-in on a buried conductor.

The new Genny 4 (optional), with a new integrated logic design, provides a class-first simultaneous dual-frequency signal output design. Alongside the familiar 33kHz locate signal for general purpose locates, the Genny 4 transmits a second frequency designed to facilitate location of small diameter cables such as telecoms and street lighting, including spurs. For tricky locates, the new power boost function enables the locate signal to travel further and deeper, and couple onto utilities more easily.

Dig More Safely
Radiodetection’s proprietary StrikeAlert™ has been improved to reduce the number of shallow cable strikes. The C.A.T4 guides users towards better and safer working practices through its optional SWING™ Rate detector and Service Due date warning.
Optional data acquisition capabilities allow Plant Supervisors to administer their fleet more safely and effectively by providing comprehensive logs of C.A.T4 usage for analysis and personnel development.

StrikeAlert™ (optional)
Minimise the risk of hitting a shallow cable with the optional StrikeAlert™ which has been enhanced and optimised to reduce the instances of false warnings.

Dynamic Overload Protection
Radiodetection’s unique digital signal processing capabilities equips the C.A.T4 with the ability to reject electrical interference. Dynamic Overload Protection gives C.A.T4 series products the ability to continue operating in electrically challenging areas, such as near substations and under power cables, where other locators’ detection circuitry may be overloaded and no longer function.

Avoidance Mode™
Sweep an area of Power, Radio and Genny signals simultaneously, saving time. C.A.T4 lets operators control the sensitivity of each mode/signal, enabling buried utilities to be pinpointed in a single pass, while Real Sound provides audio feedback derived directly from the utility located, easing identification to maximise speed whilst maintaining safety.

eCert™
eCert provides a fast and thorough test of key circuitry elements within C.A.T4, and validates their validation performance against the original factory calibration over the internet.
eCert™, activated through the C.A.T Manager software, provides a fast, thorough and convenient test of the key locating circuitry within C.A.T4, and validates its performance against the original factory calibration. Following an eCert test pass, a Radiodetection Calibration Certificate for that C.A.T4 can be printed or saved.
What's more, C.A.T Manager can reproduce the original factory calibration certificate, or any eCert certificates that it has produced, on demand.
For a complete maintenance package, Radiodetection also offers exhaustive factory-backed service and recalibration options including full mechanical integrity inspection and function testing.
High Visibility Display with Backlight
The C.A.T4’s high visibility display helps to minimise the possibility of misreading critical information from the unit. The high contrast and automatic backlight illumination provide optimum visibility in all light conditions.

C.A.T Manager™ Software (optional)
C.A.T4 locators are supported with the dedicated C.A.T Manager software package. This Windows® PC program allows plant, fleet and site managers to minimise down time by performing software upgrades, sending a service request or reproducing calibration certificates. To match individual preferences or intended use, C.A.T Manager can disable or enable C.A.T4 features such as depth estimation and warnings. User-editable fields enable plant/fleet codes and other details to be stored on the unit, simplifying records and traceability.

Genny4 Signal Boost
The Genny 4 offers, alongside its standard power mode, a Signal Boost feature which increases the output signal by up to 10 times allowing you to locate over extra distance and depth. Additionally, the simultaneous Small Diameter Locate frequency design aids detection of smaller cables including spurs.

Reverse Compatibility
CAT 4 and Genny 4 are compatible with all CAT 3 and Genny 3 accessories.


  • Product Range:
  • C.A.T4: Standard Dual frequency Cable Avoidance Tool
  • C.A.T4+: Standard Dual frequency Cable Avoidance Tool with Depth Estimation
  • gC.A.T4+: Standard Dual frequency Cable Avoidance Tool with Data-logging, GPS and Depth Estimation
  • Optional features:
  • eCert: Online Calibration Check and Certification of Product
  • CALsafe : Disables the unit when it goes beyond its re-calibration date
  • StrikeAlert™: Warns of shallow buried utilities.
  • Data-logging: Data-logging of all events when used in Power, Genny or Avoidance Modes
  • Swing Warning: Ground-breaking feature warns operators of incorrect usage to promote best working practices (gC.A.T4+ model only)
  • GPS*: Adds location information to Data-logging records
  • Service Indicator: Warns of due service date
  • Capability (Locate Depth m):
  • Power Signals (P): Frequency Range: 50Hz to 1500Hz; Sensitivity @1m: 3mA; Good Conditions: 3; Poor Conditions: 2
  • Radio Signals (R): Frequency Range: 15kHz to 30kHz; Sensitivity @1m: 25μA; Good Conditions: 2; Poor Conditions: 1
  • Genny4 Signals (G): Frequency Range:  Simultaneous 32.768kHz and 131.072kHz +/- 20Hz; Sensitivity @1m: 5μA ; Good Conditions: 4; Poor Conditions: 2
  • Avoidance Mode (A): Frequency Range: P+R+G As above; Sensitivity @1m: 5μA; Good Conditions: 4; Poor Conditions: 2
  • Performance:
  • Dynamic Range: 120dB @10Hz
  • Dynamic Overload Protection: 40dB @50Hz (automatic)
  • Locate accuracy: +/- 10% of depth
  • Depth Range: Line depth 4m, Sonde Mode 7m
  • Depth Accuracy: Line mode 5%, Sonde Mode 5%
  • Horizontal GPS Accuracy*: 3m CEP (Circular Error Probable)
  • Data-logging capacity: 24 months @8hrs day, 5 days per week
  • Service indicator: Provides 30 day warning prior to elapse date
  • Operating Modes:
  • Power: Non latching trigger On/Off when released
  • Visual Indication: Digital display
  • Audio Output: Audio signal derived directly from signal received, output through wired detachable speaker
  • Display: Burnt Glass Backlit LCD
  • Gain control: Manual Rotary 270 Degree
  • Mode control: Manual 4 position switch
  • StrikeAlert: Alarm that activates in Power, Genny and Avoidance modes when less than 30cm from Cable Avoidance Tool
  • Batteries: Requires 2 x D-Cell batteries (HR20 NiMH preferred) but alkaline LR20 can be used
  • Battery Life: 14 hours continuous, 0 to 50°c using Radiodetection NiMH Rechargeable batteries. 4hours continuous 0 to 50°c using Alkaline batteries
  • Physical Characteristics:
  • Operating Temperature Range: -20°c to +50°c
  • Storage Temperature Range: -20°c to +70°c
  • Construction: High Impact ABS Plastic
  • Ingress Protection rating : Weatherproof to NEMA3S and IP54
  • Dimensions: 71.6cm x 25.1cm x 6.4cm
  • External connection: USB 2.0, Bluetooth® Low Energy (BLE) (Android and Apple)
  • Weight 2.3kg (including batteries)
  • Warranty: 12 months
  • Recommended Service Interval: Annual 
  • Accessories:
  • Sonde: Small transmitter for tracing non-metallic pipes
  • FlexiTrace™: Sonde attached to a Cable for tracing small non-metallic pipes for use with Genny
  • Transmitter Signal Clamps: For inducing a Genny signal where direct connection to a pipe or cable is not possible
  • NiMH Rechargeable Battery: kit Allows extended working in low temperatures , 500 recharge cycles and up to 7000 hour use before disposal

  • (1) CAT4 Cable Avoidance Tools with StrikeAlert
  • (2) LR20 (D) 1.5 V alkaline
  • (1) User Manual