The Testo 435-4 (0560 4354) Multi-Function HVAC/IAQ Meter with Memory, Software, and Differential Pressure is perfect for monitoring, analyzing, and diagnosing indoor air quality, wherever you need to take important IAQ measurements. In addition, you can easily pinpoint and troubleshoot problems with HVAC systems, and immediately see the results of corrections. Commissioning, validating, benchmarking, or simply adjusting HVAC systems are all easy with the 435-4 Multi-Function HVAC/IAQ Meter.
As a multifunction meter, the 435-4 allows you to carry out all the measurements that are necessary to check and adjust ventilation and air conditioning systems, and to assess the quality of indoor air. The 435-4 accepts a wide variety of probes to measure and record airflow, humidity, temperature, and indoor air quality (IAQ) readings. With the included ComSoft Software, this data can be organized by location, analyzed, and reported.
Probe dependent menus and selectable user profiles ensure that the 435-4 Multi-Function HVAC/IAQ Meter is always ready to use. Easy setup of user defined IAQ and airflow/duct profiles allows for fast measurement of many different tasks, and with a wide variety of probe choices available, the 435-4 is ready to handle a vast array of HVAC/IAQ applications. The superb data handling will keep your readings organized and ready, however you need them, whether in a quick printout on-site, or for further analysis for placement into a report.
Applications Flow Measurement in Ventilation Ducts Using a Thermal Anemometer and Vane Anemometer The Testo 435-4 Multi-Function HVAC and IAQ Meter is compatible with compact anemometer probes and pitot tubes for measuring the flow and volumetric flow in a ventilation duct. Selecting a suitable probe or measuring instrument depends on the flow velocity in the ventilation duct. This can be broken down into three sub-ranges: low flow velocities (0 to 5 m/s), medium flow velocities (5 to 40 m/s), high flow velocities: 40, 70, 100 m/s.
The flow sensors for duct measurement are all equipped with telescopes making them easy to use in large air ducts. Air temperature and humidity can also be measured with the same probe as the flow velocity if required. According to the required application, choose between a thermal probe, vane probe or pitot tube for measuring the flow measurement in the duct.
Measurement at the Air Outlet Every duct inlet and outlet should only contain the volumetric flow that according to calculations is a basic prerequisite to an efficient functional system.
Large vane anemometers with 100 mm diameters are suitable for measuring the volumetric flows at duct outlets (order no. 0635 9435), as it integrates the flow velocity over a larger area, thereby determining disturbance from the air grille (loop method).
To measure the suction or blowing vents of air grilles and poppet valves, a volumetric flow rate funnel set is ideal (order no. 0563 4170), as is the large 100 mm vane anemometer (order no. 0635 9435). The entire volumetric flow is recorded with the aid of the funnel without the need for conversion on the basis of the flow velocity and area. This method of flow measurement is simple and reliable.
Measurement of the Air and Surface Temperature For people to be comfortable and to perform at their best, it is crucial that the rooms they occupy are correctly air conditioned. As well as the structural conditions and personal perception, the following factors also contribute significantly to the existence of a pleasant indoor climate: the indoor air and surface temperature of walls, windows, floors and ceilings.
There is a range of optional temperature probes available for the 435-4 Multi-Function HVAC/IAQ Meter. Temperature probes with a sprung cross-band sensor element for measurement on surfaces are an ideal option. The sprung cross-band sensor element fits on any surface, taking the actual temperature of the measured object in just a few seconds (for example the fast-reaction surface probe, order no. 0602 0393).
In order to allow a fast measurement of air temperature, the temperature sensor is free in Testo's air probes (e.g. NTC probe 0613 1712). Immersion/penetration probes can also be used for measurements in air. However, the response time is then about 40 to 60 times higher than the indicated value which was measured in water.
Measurement of Radiated Heat The multi-functional measuring instrument 435-4 is your reliable aid to measuring thermal comfort. The optional, attachable globe thermometer (order no. 0602 0743) enables measurement of radiated heat (that is, the operative or perceived temperature). The operative temperature measured with a Globe thermometer with a 150 mm diameter preferably corresponds with people's perceived temperature to +/- 0.41 K.
The temperature measurements in a room (air temperature and operative temperature) are to be taken in the same place and same general conditions as the measurement of indoor air velocities.
Lighting Measurement Suitable lighting in the workplace provides workers with sufficient light to be able to perform their jobs well. It helps to prevent mistakes being made, premature tiredness setting in, and maintains alertness. The Testo 435-4 and the Lux probe (order no. 0635 0545) can be used to measure and assess luminous intensity (natural or artificial light).
Turbulence Measurement The air velocity in rooms directly affects thermal comfort. The turbulence and draught levels can be referred to in the assessment of comfort. The level of turbulence indicates the air velocity fluctuation and intensity of air flow in a room. The draught rate can be generally understood as the unwanted cooling of the body due to air movement. This is defined by the percentage of people who feel uncomfortable.
The non-directional comfort probe (order no. 0628 0109) has been specially designed to measure the turbulence level in accordance with EN 13779, and to assess the draught rate. In conjunction with the multi-functional measuring instrument 435-4, standard-compliant measurement results can be analyzed directly in the device.
U-Value Measurement When redeveloping or renovating old buildings, it is crucial to be able to determine quickly if heat is being lost through the windows and walls. Only then can energy costs be reduced and redevelopment measures carried out efficiently. When assessing thermal transmission, e.g. in old buildings in need of renovation, the U-value is one of the most important values. It enables thermal assessment, e.g. leaks or the smallest air flows at windows.
Three temperature values are required for calculating the U-value: outside temperature, surface temperature of the internal wall, and indoor air temperature. A radio probe is needed to determine the U-value (order number: 0614 1635); this is placed in position outside. It transmits the readings to the measuring instrument inside. To measure the surface temperature the three wires of the U-value probe are attached to the wall with plasticine. The air temperature is recorded by a sensor located on the probe plug. The 435-4 Multi-Function HVAC/IAQ Meter automatically calculates the U-value from the three values and shows this on the display. The advantage: there is no need for manual calculation; the result is quick and accurate.
Measurement of Indoor Air Quality (CO2) Bad indoor air quality due to high concentrations of CO2 can cause tiredness, lack of concentration and even illness. Therefore, to ensure sufficient indoor air quality, the CO2 concentration should generally not exceed 1000 ppm. Values of 700 to 1500 ppm can be viewed as the "reference range".
The IAQ probe (order no. 0632 1535) is particularly suitable for monitoring indoor air quality controls. This probe can be used to record CO2, temperature and relative humidity at the same time.
CO Measurement Carbon monoxide (CO) is an odourless, invisible and tasteless gas, but also poisonous. It is produced during the incomplete combustion of substances containing carbon, such as coal, wood, oil, natural gas, etc., in heat sources and combustion engines. The CO concentration will increase quickly, particularly if there is not enough